![Lenze AC Tech LonWorks MCH Series Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/lenze-ac-tech/lonworks-mch-series/lonworks-mch-series_communications-manual_1882579010.webp)
7
RG-MHLON
Drive Setup & Programming
3.2 Bus Configuration Parameters
The Bus configuration parameters are only used to provide additional information about the installation
state of the drive. As the address information usually is assigned from the network side in a LonWorks
network, in the programming mode of the drive, these parameters are read-only.
100 NODE STATE
This parameter contains the current state of the network interface. Configured
Online is the normal run-time mode and means that the drive is commissioned
and online. Soft/Bypass/Hard Offline means the node is not participating actively
on the network.
Value
Node State
0
Unknown State
1
Unconfigured
2
Applicationless
3
Configured Online
4
Configured Offline
5
Soft Offline
6
Configured Bypass Offline
7
Hard Offline, Bypass Offline
101 NEURON ID [5]
Byte 6 of the unique Neuron ID (MSB)
102 NEURON ID [4]
Byte 5 of the unique Neuron ID
103 NEURON ID [3]
Byte 4 of the unique Neuron ID
104 NEURON ID [2]
Byte 3 of the unique Neuron ID
105 NEURON ID [1]
Byte 2 of the unique Neuron ID
106 NEURON ID [0]
Byte 1 of the unique Neuron ID (LSB)
107 NODE ADDRESS 1
Indicates the ID of the node within this subnet. A value of 0 means that it is not
assigned.
108 NODE SUBNET 1
Indicates to which subnet this node belongs. A value of 0 means that it is not