Watch the procedure
A video of this procedure is available at YouTube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
.
About this task
Step 1. Make sure the 2.5-drive is removed from drive bay 2, see
“Remove a simple-swap drive (bay 1-2)”
Step 2. Make sure the post on the M.2 drive retainer is lifted away from the retainer.
Step 3. Install the M.2 drive.
Note:
The thermal sensor cable should be placed under the M.2 drive.
a.
Position the M.2 drive at an angle and insert it to the M.2 connector.
b.
Place down the M.2 drive onto the M.2 drive retainer.
c.
Insert the retainer post into the retainer to secure the M.2 drive in place.
Figure 84. Installing the M.2 drive
After you finish
1. If necessary, reinstall the 2.5-inch drive to the drive bay 2, see
“Install a simple-swap drive (bay 1-2)” on
.
2. Proceed to complete the parts replacement, see
“Complete the parts replacement” on page 158
Remove the M.2 drive retainer
Follow this procedure to remove the M.2 drive retainer.
106
ThinkSystem ST50 V2 Maintenance Manual