Watch the procedure
. A video of the replacement process is available:
•
•
Step 1. Connect the power cable to the backplane. If this cable is connected to the storage interposer, you
might find it easier to disconnect it from the storage interposer and then reconnect it to the storage
interposer after the backplane is installed. See “Cable routing for drives” on page 40.
Step 2. Install the hard disk drive backplane.
Note:
Existing cables might need to be removed from their retaining clips or moved to the side to
install the backplane.
Figure 34. Hard disk drive backplane (upper) installation
Align the backplane with its location in the tray; then, insert the backplane and push it down until it
is fully seated.
Step 3. Connect the data cables to the backplane. (SAS backplanes have only one data cable. NVMe
backplanes have two data cables.) See “Cable routing for drives” on page 40.
Step 4. Repeat Step 1 on page 222, Step 2 on page 222, and Step 3 on page 222 for each hard disk drive
backplane being installed in the upper tray.
Step 5. Turn the tray upside down.
Step 6. Route and connect the data cables. See “Cable routing for drives” on page 40.
• Route each SAS data cable to its connector on the RAID adapter; then, connect the SAS cable.
• Route each NVMe data cable to its connector on a system board or optional storage tray; then,
connect the NVMe cable.
Step 7. Make sure that all power cables are connected to the storage interposer.
Step 8. Make sure that all of the cables are correctly routed after they have been connected.
After you install the hard disk drive backplane:
1. Install the fan cage. See “Install a fan cage (upper tray)” on page 317.
2. Turn the tray right-side up.
222
ThinkSystem SR950 Setup Guide
Содержание ThinkSystem SR950
Страница 1: ...ThinkSystem SR950 Setup Guide Machine Types 7X12 7X11 and 7X13 ...
Страница 55: ...Figure 22 Server components Chapter 2 Server components 51 ...
Страница 276: ...272 ThinkSystem SR950 Setup Guide ...
Страница 282: ...278 ThinkSystem SR950 Setup Guide ...
Страница 286: ...282 ThinkSystem SR950 Setup Guide ...
Страница 389: ......
Страница 390: ......