G8272 Installation Guide
Replacing the G8272
Preparing and Returning the G8272
If replacing the G8272, remove all associated components and options according to
the instructions in this chapter. Remove and retain clips, cords, cables, modules,
caps or blanks, air-duct option (if installed), and any mounting hardware. These
items can then be reinstalled on the replacement unit.
When you remove the G8272 from the rack, record the product Machine
Type-Model (MTM) number and serial number to use for the replacement switch.
See
“Before Installing the G8272” on page 34
to locate the product information
labels on the switch or through the switch firmware interface.
To return the chassis to customer service for replacement, see
Help and Technical Assistance“
to help you gather all the required information that
is necessary to return a component. After you remove the G8272 unit, securely pack
it for shipping.
Replace power and fan modules. For details, see
“Removing and Replacing a Power
“Removing and Replacing a Fan Module” on
.
Install the replacement G8272 hardware as directed in
). Once the hardware is installed, configure the Vital
Product Data (VPD) on the replacement switch as shown in the following section.
Configuring Vital Product Data
After you install the replacement G8272 hardware (the new unit), you must
configure the new unit to use the VPD of the unit which was removed (the old unit),
in order to avoid losing any licensed electronic entitlement data. The required
information consists of the old unit’s MTM and serial number, which was collected
from the old unit according to
“Before Installing the G8272” on page 34
.
To configure the VPD on a new switch, complete the following steps.
1.
Log in to the new G8272 as directed in
Chapter 5, “Initializing the G8272“
. At the
login prompt, the default username is
admin
and the default password is
admin
.
2.
Use the following CLI commands to enter the Global Configuration mode:
G8272>
enable
G8272#
configure [terminal]
G8272(config)#
Содержание RackSwitch G8272
Страница 1: ...Lenovo RackSwitch G8272 Installation Guide For Lenovo Network Operating System ...
Страница 6: ...6 Lenovo G8272 Installation Guide ...
Страница 16: ...16 G8272 Installation Guide ...
Страница 21: ... Copyright Lenovo 2019 21 Chapter 2 Switch Components This chapter describes the G8272 hardware components ...
Страница 56: ...56 G8272 Installation Guide ...
Страница 90: ...90 G8272 Installation Guide ...
Страница 96: ...96 G8272 Installation Guide ...
Страница 112: ...112 G8272 Installation Guide ...
Страница 118: ...118 G8272 Installation Guide ...