Diagnostic Error Code
FRU/Action
030-03X-XXX 030-04X-XXX
SCSI interface error
1.
SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-195-XXX
SCSI interface Test aborted by user
Information only
Restart the test, if necessary
030-196-XXX
SCSI interface test halt, error threshold
exceeded
1.
Press F3 to review the log file
2. Restart the test to reset the log file
030-197-XXX
SCSI interface test warning
1.
Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
030-198-XXX
SCSI interface test aborted
1.
If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 39
2. Flash the system and re-test. See “Flash update
procedures” on page 521
3. Go to “Undetermined problems” on page 65
030-199-XXX
SCSI interface test failed, cause unknown
1. Go to “Undetermined problems” on page 65
2. Flash the system and re-test. See “Flash update
procedures” on page 521
3. Replace component under function test
035-000-XXX
RAID interface Test Passed
No action
035-0XX-XXX
RAID interface Failure
1.
RAID signal cable
2. RAID device
3. RAID adapter card, if installed
4. System board
035-195-XXX
RAID interface Test aborted by user
Information only
Restart the test, if necessary
035-196-XXX
RAID interface test halt, error threshold
exceeded
1.
Press F3 to review the log file
2. Restart the test to reset the log file
035-197-XXX
RAID interface test warning
1.
Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
Chapter 7
.
Symptom-to-FRU Index
55
Содержание 7269D7U - Topseller M58e Sff E7500 2.93G 3Gb 320Gb Dvdrw W7p/Xpp
Страница 2: ......
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkCentre Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 27: ...Chapter 2 Safety information 21 ...
Страница 31: ...Chapter 2 Safety information 25 ...
Страница 38: ...32 ThinkCentre Hardware Maintenance Manual ...
Страница 48: ...42 ThinkCentre Hardware Maintenance Manual ...
Страница 72: ...66 ThinkCentre Hardware Maintenance Manual ...
Страница 126: ...120 ThinkCentre Hardware Maintenance Manual ...
Страница 530: ...524 ThinkCentre Hardware Maintenance Manual ...
Страница 534: ...528 ThinkCentre Hardware Maintenance Manual ...
Страница 535: ......
Страница 536: ...Part Number 53Y6397 Printed in USA 1P P N 53Y6397 53Y6397 ...