Diagnostic Error Code
FRU/Action
005-199-XXX
Video test failed, cause unknown
1. Go to “Undetermined problems” on page 65
2. Flash the system and re-test. See “Flash update
procedures” on page 521
3. Replace component under function test
005-2XX-XXX 005-3XX-XXX
Video subsystem error
1.
Video card, if installed
2. System board
006-000-XXX
Diskette interface Test Passed
No action
006-0XX-XXX
Diskette interface error
1.
Diskette drive Cable
2. Diskette drive
3. System board
006-195-XXX
Diskette interface Test aborted by user
Information only
Restart the test, if necessary
006-196-XXX
Diskette interface test halt, error threshold
exceeded
1.
Press F3 to review the log file
2. Restart the test to reset the log file
006-197-XXX
Diskette interface test warning
1.
If a component is called out, make sure it is
connected and/or enabled
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
006-198-XXX
Diskette interface test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test. See “Flash update
procedures” on page 521
3. Go to “Undetermined problems” on page 65
006-199-XXX
Diskette interface test failed, cause
unknown
1. Go to “Undetermined problems” on page 65
2. Flash the system and re-test
3. Replace component under function test
006-25X-XXX
Diskette interface Error
1.
Diskette drive cable
2. Diskette drive
3. System board
011-000-XXX
Serial port Interface Test Passed
No action
011-001-XXX
Serial port Presence
1.
Remove external serial device, if present
2. Run setup, enable port
3. System board
011-002-XXX 011-003-XXX
Serial port Timeout/Parity
error
System board
011-013-XXX 011-014-XXX
Serial port Control
Signal/Loopback test failure
System board
011-015-XXX
Serial port External Loopback failure
1.
Wrap plug
2. System board
Chapter 7
.
Symptom-to-FRU Index
49
Содержание 7269D7U - Topseller M58e Sff E7500 2.93G 3Gb 320Gb Dvdrw W7p/Xpp
Страница 2: ......
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkCentre Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 27: ...Chapter 2 Safety information 21 ...
Страница 31: ...Chapter 2 Safety information 25 ...
Страница 38: ...32 ThinkCentre Hardware Maintenance Manual ...
Страница 48: ...42 ThinkCentre Hardware Maintenance Manual ...
Страница 72: ...66 ThinkCentre Hardware Maintenance Manual ...
Страница 126: ...120 ThinkCentre Hardware Maintenance Manual ...
Страница 530: ...524 ThinkCentre Hardware Maintenance Manual ...
Страница 534: ...528 ThinkCentre Hardware Maintenance Manual ...
Страница 535: ......
Страница 536: ...Part Number 53Y6397 Printed in USA 1P P N 53Y6397 53Y6397 ...