Diagnostic Error Code
FRU/Action
015-195-XXX
USB port Test aborted by user
Information only
Restart the test, if necessary
015-196-XXX
USB port test halt, error threshold exceeded
1.
Press F3 to review the log file
2. Restart the test to reset the log file
015-197-XXX
USB port test warning
1.
Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
015-198-XXX
USB port test aborted
1.
If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 39
2. Flash the system and re-test. See “Flash update
procedures” on page 521
3. Go to “Undetermined problems” on page 65
015-199-XXX
USB port test failed, cause unknown
1. Go to “Undetermined problems” on page 65
2. Flash the system and re-test. See “Flash update
procedures” on page 521
3. Replace component under function test
018-000-XXX
PCI Card Test Passed
No action
018-0XX-XXX
PCI Card Failure
1.
Riser card, if installed
2. System board
018-195-XXX
PCI Card Test aborted by user
1.
PCI card
2.
Information only
Restart the test, if necessary
018-196-XXX
PCI Card test halt, error threshold exceeded
1.
Press F3 to review the log file
2. Restart the test to reset the log file
018-197-XXX
PCI Card test warning
1.
Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
018-198-XXX
PCI Card test aborted
1.
If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 39
2. Flash the system and re-test. See “Flash update
procedures” on page 521
3. Go to “Undetermined problems” on page 65
52
ThinkCentre Hardware Maintenance Manual
Содержание 7269D7U - Topseller M58e Sff E7500 2.93G 3Gb 320Gb Dvdrw W7p/Xpp
Страница 2: ......
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkCentre Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 27: ...Chapter 2 Safety information 21 ...
Страница 31: ...Chapter 2 Safety information 25 ...
Страница 38: ...32 ThinkCentre Hardware Maintenance Manual ...
Страница 48: ...42 ThinkCentre Hardware Maintenance Manual ...
Страница 72: ...66 ThinkCentre Hardware Maintenance Manual ...
Страница 126: ...120 ThinkCentre Hardware Maintenance Manual ...
Страница 530: ...524 ThinkCentre Hardware Maintenance Manual ...
Страница 534: ...528 ThinkCentre Hardware Maintenance Manual ...
Страница 535: ......