Diagnostic error codes
Refer to the following diagnostic error codes when using the diagnostic tests. See “Running tests” on page
36 for the specific type for information about the Diagnostic programs.
In the following index,
X
can represent any number.
Diagnostic Error Code
FRU/Action
000-000-XXX
BIOS Test Passed
No action
000-002-XXX
BIOS Timeout
1.
Flash the system. See “Flash update procedures”
on page 521
2. System board
000-024-XXX
BIOS Addressing test failure
1.
Flash the system. See “Flash update procedures”
on page 521
2. System board
000-025-XXX
BIOS Checksum Value error
1.
Flash the system. See “Flash update procedures”
on page 521
2. System board
000-026-XXX
FLASH data error
1.
Flash the system. See “Flash update procedures”
on page 521
2. System board
000-027-XXX
BIOS Configuration/Setup error
1.
Run Setup
2. Flash the system. See “Flash update procedures”
on page 521
3. System board
000-034-XXX
BIOS Buffer Allocation failure
1.
Reboot the system
2. Flash the system. See “Flash update procedures”
on page 521
3. Run memory test
4. System board
000-035-XXX
BIOS Reset Condition detected
1.
Flash the system. See “Flash update procedures”
on page 521
2. System board
000-036-XXX
BIOS Register error
1.
Flash the system. See “Flash update procedures”
on page 521
2. System board
000-038-XXX
BIOS Extension failure
1.
Flash the system. See “Flash update procedures”
on page 521
2. Adapter card
3. System board
000-039-XXX
BIOS DMI data error
1.
Flash the system. See “Flash update procedures”
on page 521
2. System board
000-195-XXX
BIOS Test aborted by user
Information only
Restart the test, if necessary
000-196-XXX
BIOS test halt, error threshold exceeded
1.
Press F3 to review the log file
2. Restart the test to reset the log file
44
ThinkCentre Hardware Maintenance Manual
Содержание 7269D7U - Topseller M58e Sff E7500 2.93G 3Gb 320Gb Dvdrw W7p/Xpp
Страница 2: ......
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkCentre Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 27: ...Chapter 2 Safety information 21 ...
Страница 31: ...Chapter 2 Safety information 25 ...
Страница 38: ...32 ThinkCentre Hardware Maintenance Manual ...
Страница 48: ...42 ThinkCentre Hardware Maintenance Manual ...
Страница 72: ...66 ThinkCentre Hardware Maintenance Manual ...
Страница 126: ...120 ThinkCentre Hardware Maintenance Manual ...
Страница 530: ...524 ThinkCentre Hardware Maintenance Manual ...
Страница 534: ...528 ThinkCentre Hardware Maintenance Manual ...
Страница 535: ......
Страница 536: ...Part Number 53Y6397 Printed in USA 1P P N 53Y6397 53Y6397 ...