3. Remove the heat sink and fan assembly cable from the system board. Note the cable location. See
“Locating parts on the system board ” on page 79.
4. Follow this sequence to remove the heat sink from the system board:
a. Partially remove screw
1
, then fully remove screw
2
, and fully remove screw
1
.
b. Partially remove screw
3
, then fully remove screw
4
, and fully remove screw
3
.
5. Carefully lift the heat sink off of the system board.
6. Remove the plastic cover from the bottom of the new heat sink to expose the heat sink grease (this cover
protects the heat sink grease from contamination).
Notes:
a. Do not remove the plastic cover until you are ready to install the heat sink and fan assembly on the
microprocessor. Do not touch the grease on the heat sink and fan assembly. Do not put the heat
sink and fan assembly anywhere except on the microprocessor after the plastic cover has been
removed and the grease exposed.
b. Some heat sink part numbers will have orientation labels showing "Front of System." Heat Sinks that
do not have orientation labels should be oriented so the fan cable is toward the board connector
labeled "CPU Fan."
7. Place the new heat sink into position.
Important:
Do not touch the thermal grease while handling the heat sink.
8. Align the four screws on the heat sink with the four mounting studs in the chassis.
9. Follow this sequence to install the screws, noting that fully tight is 5 in-lbs +/- 0.5 in-lbs:
a. Partially tighten screw
1
, then fully tighten screw
2
, and fully tighten screw
1
.
b. Partially tighten screw
3
, then fully tighten screw
4
, and fully tighten screw
3
.
Chapter 10
.
Replacing FRUs (Type 4105, 4157, 4217)
89
Содержание 4157 - ThinkStation S20 - 2 GB RAM
Страница 1: ...ThinkStation Hardware Maintenance Manual Machine Type 4105 4155 4157 4158 4217 4218 ...
Страница 2: ......
Страница 3: ...ThinkStation Hardware Maintenance Manual Machine Type 4105 4155 4157 4158 4217 4218 ...
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkStation Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 ThinkStation Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 27: ...Chapter 2 Safety information 21 ...
Страница 31: ...Chapter 2 Safety information 25 ...
Страница 38: ...32 ThinkStation Hardware Maintenance Manual ...
Страница 56: ...50 ThinkStation Hardware Maintenance Manual ...
Страница 80: ...74 ThinkStation Hardware Maintenance Manual ...
Страница 93: ...Chapter 10 Replacing FRUs Type 4105 4157 4217 87 ...
Страница 124: ...118 ThinkStation Hardware Maintenance Manual ...
Страница 264: ...258 ThinkStation Hardware Maintenance Manual ...
Страница 268: ...262 ThinkStation Hardware Maintenance Manual ...
Страница 274: ...268 ThinkStation Hardware Maintenance Manual ...
Страница 275: ......
Страница 276: ...Part Number 53Y4348 Printed in USA 1P P N 53Y4348 53Y4348 ...