Page 3
XP25
Electrical Data
208/230V-60 Hz-1 Ph
Model Number
Unit
Compressor
Outdoor Fan (RPM varies with compressor RPM)
Maximum
Over-
current
Protection
(amps)
1
Minimum
Circuity
Ampacity
2
Rated
Load
Amps
(RLA)
Locked
Rotor
Amps
(LRA)
Motor
HP
CFM
RPM
WATTS
Full
Load
Amps
(FLA)
MAX
MIN
MAX
MIN
MAX
MIN
XP25-024-230-01
25
15.7
10.30
18.00
1/3
2580
1845
723
515
70
32
2.80
208/230V-60 Hz-1 Ph
Model Number
Unit
Compressor
Outdoor Fan (RPM varies with compressor RPM)
Maximum
Over-
current
Protection
(amps)
1
Minimum
Circuity
Ampacity
2
Rated
Load
Amps
(RLA)
Locked
Rotor
Amps
(LRA)
Motor
HP
CFM
RPM
WATTS
Full
Load
Amps
(FLA)
MAX
MIN
MAX
MIN
MAX
MIN
XP25-036-230-01
25
20.3
14.00
18.00
1/3
4130
1865
850
390
214
40
2.80
208/230V-60 Hz-1 Ph
Model Number
Unit
Compressor
Outdoor Fan (RPM varies with compressor RPM)
Maximum
Over-
current
Protection
(amps)
1
Minimum
Circuity
Ampacity
2
Rated
Load
Amps
(RLA)
Locked
Rotor
Amps
(LRA)
Motor
HP
CFM
RPM
WATTS
Full
Load
Amps
(FLA)
MAX
MIN
MAX
MIN
MAX
MIN
XP25-048-230-01
40
33.7
24.70
29.00
1/3
4040
3315
805
658
172
98
2.80
208/230V-60 Hz-1 Ph
Model Number
Unit
Compressor
Outdoor Fan (RPM varies with compressor RPM)
Maximum
Over-
current
Protection
(amps)
1
Minimum
Circuity
Ampacity
2
Rated
Load
Amps
(RLA)
Locked
Rotor
Amps
(LRA)
Motor
HP
CFM
RPM
WATTS
Full
Load
Amps
(FLA)
MAX
MIN
MAX
MIN
MAX
MIN
XP25-060-230-01
40
34.9
25.70
29.00
1/3
4240
3025
845
600
198
76
2.80
1
HACR type circuit breaker or fuse.
2
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
Содержание XP25-024-230-01
Страница 46: ...Page 46 XP25 Typical Unit Wiring Diagrams Figure 24 Typical Unit Wiring XP25 024 and 036...
Страница 47: ...Page 47 XP25 Figure 25 Typical Unit Wiring XP25 048 and 060...
Страница 73: ...Page 73 XP25 Perform DC volt checks 19 23 VDC between FAN PWM and COM Figure 54 VAC Voltage Check...
Страница 89: ...Page 89 XP25 Figure 67 XP25 Charging Sticker...