Page 6
XP25
VAPOR VALVE
AND GAUGE
PORT
REVERSING
VALVE
LIQUID LINE BI-FLOW
FILTER DRIER
(HFC-410A)
LIQUID VALVE AND
GAUGE PORT
TRUE SUCTION LINE
PORT
HR1 CRANKCASE
HEATER (40W, 240VAC)
MUFFLER
CHECK EXPANSION
VALVE - (HFC-410A)
EXPANSION VALVE SENSING
BULB
CHARGE
C0MPENSATOR
(INTERNAL VOLUME
30.0 CUBIC INCHES)
LIQUID LINE SENSOR
VARIABLE-CAPACITY
COMPRESSOR SPEED - HFC-410A,
3-PHASE
VAPOR VALVE
AND GAUGE
PORT
REVERSING
VALVE
LIQUID LINE BI-FLOW
FILTER DRIER
LIQUID VALVE AND
GAUGE PORT
TRUE SUCTION LINE
PORT
MUFFLER
DISCHARGE LINE
CHECK EXPANSION VALVE SENSING BLUB
HIGH PRESSURE SWITCH - NORMALLY CLOSED, SWITCH
OPENS WHEN SYSTEM PRESSURES REACH 590+15 PSIG,
CLOSES WHEN PRESSURES DROP BELOW 418+15 PSIG
HR1 CRANKCASE HEATER (40W,
240VAC)
COMPRESSOR TOP CAP SWITCH (THERMAL)
VARIABLE-CAPACITY
COMPRESSOR SPEED - HFC-410A,
60HZ, 3-PHASE
CRANKCASE HEATER THERMOSTAT
LIQUID LINE SENSOR
Typical Plumbing Components (-024 and -048)
Typical Plumbing Components (-036 and -060)
CRANKCASE HEATER
THERMOSTAT (S40) OPENS AT
70ºF, CLOSES AT 50ºF
COMPRESSOR TOP CAP
SWITCH (THERMAL)
HIGH PRESSURE SWITCH - NORMALLY CLOSED, SWITCH OPENS
WHEN SYSTEM PRESSURES REACH 590+15 PSIG, CLOSES
WHEN PRESSURES DROP BELOW 418+15 PSIG
LOW PRESSURE SWITCH - NORMALLY OPEN, SWITCH CLOSES
WHEN SYSTEM PRESSURES GO ABOVE 40±5 PSIG. OPENS
WHEN SYSTEM PRESSURES GO BELOW 25±5 PSIG
CHECK EXPANSION
VALVE - (HFC-410A)
LOW PRESSURE SWITCH - NORMALLY OPEN, SWITCH CLOSES
WHEN SYSTEM PRESSURES GO ABOVE 40±5 PSIG. OPENS
WHEN SYSTEM PRESSURES DROP BELOW 25±5 PSIG
Figure 2. Plumbing (Component Locations and Specifications)
Содержание XP25-024-230-01
Страница 46: ...Page 46 XP25 Typical Unit Wiring Diagrams Figure 24 Typical Unit Wiring XP25 024 and 036...
Страница 47: ...Page 47 XP25 Figure 25 Typical Unit Wiring XP25 048 and 060...
Страница 73: ...Page 73 XP25 Perform DC volt checks 19 23 VDC between FAN PWM and COM Figure 54 VAC Voltage Check...
Страница 89: ...Page 89 XP25 Figure 67 XP25 Charging Sticker...