background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

9

Step 4.

 Note: Chimney sections are constructed

with a unique locking tab design, which en-
sures an immediate, tight assembly between
sections. Plan your chimney requirements care-
fully before assembly as chimney is difficult to
disassemble after installation. If disassembled,
the tabs might become damaged. Be certain
tabs are properly formed to ensure locking tabs
engage properly.

The Security Chimneys FTF13 chimney system
is a two piece chimney, which snap together
from the fireplace up. Start with the inner flue
section with the lanced end up, snap lock it in to
the matching collar on top of the fireplace. At all
subsequent joints, the upper flue section fits
into the preceding flue section. Each piece
snaps together by means of locking tabs (9
locking tabs per joint). Check each piece by
pulling up slightly from the top to ensure proper
engagement before installing the next section.
If the flue has been installed correctly, it will not
separate when you test it. Also, the inner flue
joint where each section is joined should be
tight and flat without gaps (

Figure 24 ).

2" Min. Air Space
To Combustibles

Figure 24

Outer pipe section installs in just the opposite
way; the lanced end goes down and each new
section goes OVER the outside of the previous
section installed (

Figure 25 ).

Locking

Tabs

(Lances)

Figure 25

Figure 26

Security's chimney sections do not need to be
screwed together. Additional reinforcement is
not necessary except in certain offset condi-
tions (refer to page 12, 

Figure 36 ).

Step 5. The height of vertical chimney pipe
supported only by the fireplace must not ex-
ceed 30'. Chimney heights above 30' must be
supported by a Model FTF13-S4 stabilizer in-
stalled at 30' intervals.

Note: The Model FTF13-S4 adds 3" net effective
height to the total chimney system.

Install the Model FTF13-S4 stabilizer by fitting
inner section down into respective section of
proceeding flue pipe and locking outer stabi-
lizer section into place over the outer chimney
pipe. Position for proper clearance through
framed opening and nail straps securely (under
tension in “shear”) into place on framing. Use
8d nails. Attach successive lengths of chimney
pipe directly to stabilizer using same tech-
niques as described in Step 4 (

Figure 27 ).

Figure 27

Figure 29

Next, slide roof flashing over extended chimney
section that previously has been installed above
the roof opening in Step 4. FTF10 flashings
require flashing spacers. Slide flashing all the
way down until the flashing base rests flat on
the roof (

Figure 28 ). Again, check the vertical

position of the chimney and the 2" minimum air
space to combustibles.

Figure 28

Note: Do not caulk or seal the ventilating openings.

Step 7. Secure flashing by nailing along the
perimeter into roof using 8d nails. If shingled
roof, slide upper end and sides of roof flashing
under shingles (trim if necessary), seal the top
and both sides of the flashing to the roof with
roof caulking. Cover nail heads with roof caulk-
ing (

Figure 29 ).

Note: Do not apply excessive pressure to any
subsequent chimney sections following the
stabilizer when installing. Ensure each subse-
quent chimney section is securely attached by
testing as noted in Step 4.

Step 6. Select the proper Security Chimneys
roof flashing based on pitch of roof. Use chart
below for selection:

Roof Pitch

Model

Flat to 6/12

F10F6

6/12 to 12/12

F10F12

Note: Assemble one component of chimney at
a time (inner section first, then outer section
last) before proceeding with the next complete
section.

Continue to assemble the chimney up through
framed opening. Assemble just enough to pen-
etrate the roof flashing openings (

Figure 26 ).

Always maintain 2" minimum air space to com-
bustible materials and always check each chim-
ney joint (inner and outer) to ensure proper
engagement. Check vertical alignment of chim-
ney so that it projects from the roof in true
vertical position.

Stabiliz

er

Note: F10 flashings and firestops are compat-
ible with FTF13 chimney.

FTF13 Chimney

FTF10 Flashing

Flashing Spacers

Do Not Seal

Содержание Signature CollectionEST-48-H ESTATE SERIES

Страница 1: ...its components under any circumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chimney components and accessories may void the warranty listi...

Страница 2: ...damage as a result of handling or transporta tion These items should be inspected by your distributor or qualified factory representative to ensure safe condition When in doubt con sult your distribu...

Страница 3: ...obile homes These fireplace systems are designed for in stallation in accordance with the National Fire Protection Standard for chimneys fireplaces and solid fuel burning appliances NFPA 211 and in ac...

Страница 4: ...amper is controlled through the use of a control lever located within the firebox opening at the top center just behind the firebox lintel Figure 3 The control lever snaps into place at the ex treme r...

Страница 5: ...e Zone 45 12 Door Opening 1 12 The safety strips should extend from front of the fireplace at least 2 and should extend to be at least flush with the sides In the event a wooden support is used to ele...

Страница 6: ...to be attached to the rear wall then the framed depth must be measured from the drywall surface It is important that this dimension be exact If the appliance is to be elevated above floor level a sol...

Страница 7: ...igure 14 A B Ceiling Framing C D Roof Framing Corner Installation K D A E F Back Wall of Chase Enclosure Including Finising Materials if any Rough Framing Face Unfinished Shown FOAK Combustion Air Kit...

Страница 8: ...chimney use 30 firestop spacer Model F10FS30 2 Use one nail on opposite sides to hold firestop spacer in position Nail permanently using at least two 2 more 8d nails after chimney sections have been a...

Страница 9: ...ding flue pipe and locking outer stabi lizer section into place over the outer chimney pipe Position for proper clearance through framedopeningandnailstrapssecurely under tension in shear into place o...

Страница 10: ...ng tabs are firmly engaged 4 PullupslightlyonCTDtoensurelockingjoint has firmly engaged Using a FTF13 CT1 Chase Termination Refer to specific installation instructions in cluded with FTF13 CT1 chase t...

Страница 11: ...is 15 6 higher with offsets The maximum height for the system is 80 To determine the number of chimney sections andchimneycomponentsrequired followthese steps 1 Determine the total vertical height of...

Страница 12: ...hes Feet Inches 12 18 36 MM M 461 38 5 0 1 13 11722 11 72 465 38 9 2 0 13 11824 11 82 471 39 3 1 1 13 11976 11 98 479 39 11 0 0 14 12179 12 18 489 40 9 1 0 14 12433 12 43 495 41 3 0 1 14 12586 12 59 4...

Страница 13: ...2178 45 87 1 0 0 3 1 1149 2223 46 89 1 0 0 1 2 1175 2261 48 91 1 0 2 0 2 1226 2324 49 94 1 0 1 5 0 1257 2400 51 97 1 0 1 1 2 1302 2483 54 103 1 0 0 2 2 1378 2616 55 104 1 0 0 0 3 1403 2654 56 106 1 0...

Страница 14: ...E OUTSIDE AIR IS 50 FEET ABOVE THE HEARTH PROVING THE AIR INLET IS TERMI NATED A MINIMUM OF THREE 3 FEET BE LOW THE CHIMNEY CAP LEVEL Note Combustion air inlet ducts must not terminate in attic space...

Страница 15: ...surface of the indentation The refrac torymaterialisverythininthisareaandiseasily removed Once a small hole has been made continue tapping until you have reached suffi cientdiameterforthegaslinetofit...

Страница 16: ...ick must this material be Using the k formula Desired k value of desired Min Thickness Required material per inch x of listed Thickness k value of listed material material per inch TM inches kM x T1 8...

Страница 17: ...0 2 Offset Return Package 30 63L24 FTF13 ES30 INSTALLATION COMPONENTS The following items are available for use in the installation of this appliance The sum of all R values is 70 10 068 5825 1 4505 T...

Страница 18: ...9 FTF13 12 63L20 FTF13 18 Chimney Section 63L21 FTF13 36 63L40 F10F6 Flashing 63L41 F10F12 Round Termination 63L44 FTF13 CTD Firestop Spacer Flat 63L36 F10FS 2 INSTALLATION COMPONENTS Storm Collar 63L...

Страница 19: ...NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 19...

Страница 20: ...ges at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S...

Отзывы: