background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

13

Figure 36

A

1

C

1

B

1

B

2

C

2

A

2

A

1

C

1

B

1

B

2

C

2

A

2

Figure 37

Chimney

Section

Joints

No. 8 x 1/2" SMS

Screws Required At

Ever

y Joint Past 6'

No Screws Required In

Joints For First 6' of Offset

4'

6'

FTF13 OFFSET ELEVATION CHART

A

B

FTF13-ES30

Number of FTF13

A

B

Offset

Height

Offset/Return

FTF13-S4

Chimney Sections

Offset

Height

(Inches)

(Inches)

Elbow Set

Stabilizer

12"

18"

36"

(mm)

(mm)

4

15

³⁄₄

1

0

0

0

0

102

400

9

24

¹⁄₂

1

0

1

0

0

229

622

12

29

³⁄₄

1

0

0

1

0

305

756

14

¹⁄₄

33

¹⁄₂

1

0

2

0

0

362

851

17

¹⁄₄

38

¹⁄₂

1

0

1

1

0

438

978

20

¹⁄₄

43

³⁄₄

1

0

0

2

0

514

1111

21

45

¹⁄₄

1

0

0

0

1

533

1149

22

¹⁄₄

47

¹⁄₂

1

0

2

1

0

565

1207

25

¹⁄₄

52

¹⁄₂

1

0

1

2

0

641

1334

26

¹⁄₄

54

¹⁄₄

1

0

1

0

1

667

1378

28

¹⁄₄

57

³⁄₄

1

0

0

3

0

718

1467

29

¹⁄₄

59

¹⁄₄

1

0

0

1

1

743

1505

31

¹⁄₄

63

1

0

2

0

1

794

1600

32

¹⁄₂

65

1

0

4

1

0

826

1651

34

¹⁄₄

68

¹⁄₄

1

0

1

1

1

870

1734

36

¹⁄₄

71

³⁄₄

1

0

3

0

1

921

1822

37

¹⁄₄

73

¹⁄₄

1

0

0

2

1

946

1861

38

¹⁄₄

75

1

0

0

0

2

972

1905

39

¹⁄₄

77

1

0

2

1

1

997

1956

41

¹⁄₂

80

¹⁄₂

1

0

1

4

0

1054

2045

43

¹⁄₄

83

³⁄₄

1

0

1

0

2

1099

2127

44

¹⁄₂

85

³⁄₄

1

0

3

1

1

1130

2178

45

¹⁄₄

87

¹⁄₂

1

0

0

3

1

1149

2223

46

¹⁄₄

89

1

0

0

1

2

1175

2261

48

¹⁄₄

91

¹⁄₂

1

0

2

0

2

1226

2324

49

¹⁄₂

94

¹⁄₂

1

0

1

5

0

1257

2400

51

¹⁄₄

97

³⁄₄

1

0

1

1

2

1302

2483

54

¹⁄₄

103

1

0

0

2

2

1378

2616

55

¹⁄₄

104

¹⁄₂

1

0

0

0

3

1403

2654

56

¹⁄₂

106

¹⁄₂

1

0

2

1

2

1435

2705

59

¹⁄₂

111

³⁄₄

1

0

1

2

2

1511

2838

61

³⁄₄

116

1

1

1

0

3

1568

2946

64

³⁄₄

121

¹⁄₄

1

1

0

1

3

1645

3080

67

124

³⁄₄

1

1

2

0

3

1702

3169

69

127

³⁄₄

1

1

1

3

2

1753

3245

70

130

1

1

1

1

3

1778

3302

73

135

¹⁄₄

1

1

0

2

3

1854

3435

75

138

³⁄₄

1

1

2

1

3

1905

3524

79

145

¹⁄₂

1

1

1

0

4

2007

3696

80

¹⁄₄

147

¹⁄₂

1

1

3

1

3

2038

3747

82

150

³⁄₄

1

1

0

1

4

2083

3829

87

159

¹⁄₂

1

1

1

1

4

2210

4051

INSTALLING OFFSETS

First, review the Offset Elevation Chart and see
Figure 39  for reference.

Step 1. Determine the offset distance where
chimney is to pass through the first ceiling-
dimension “A.” To find this point on your ceil-
ing, first determine the center point for a verti-
cal chimney following the instructions for ver-
tical installation.

Measure height to the ceiling from the top of
fireplace-dimension  “B.” Use the appropriate
Offset Elevation Chart to find dimension “A.”
Mark point where you will drive your nail to
show the center point for your offset ceiling cut.

Step 2. Proceed by using the Straight Up Instal-
lation Instructions for cutting and framing ceil-
ing and roof openings.

Содержание Signature CollectionEST-48-H ESTATE SERIES

Страница 1: ...its components under any circumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chimney components and accessories may void the warranty listi...

Страница 2: ...damage as a result of handling or transporta tion These items should be inspected by your distributor or qualified factory representative to ensure safe condition When in doubt con sult your distribu...

Страница 3: ...obile homes These fireplace systems are designed for in stallation in accordance with the National Fire Protection Standard for chimneys fireplaces and solid fuel burning appliances NFPA 211 and in ac...

Страница 4: ...amper is controlled through the use of a control lever located within the firebox opening at the top center just behind the firebox lintel Figure 3 The control lever snaps into place at the ex treme r...

Страница 5: ...e Zone 45 12 Door Opening 1 12 The safety strips should extend from front of the fireplace at least 2 and should extend to be at least flush with the sides In the event a wooden support is used to ele...

Страница 6: ...to be attached to the rear wall then the framed depth must be measured from the drywall surface It is important that this dimension be exact If the appliance is to be elevated above floor level a sol...

Страница 7: ...igure 14 A B Ceiling Framing C D Roof Framing Corner Installation K D A E F Back Wall of Chase Enclosure Including Finising Materials if any Rough Framing Face Unfinished Shown FOAK Combustion Air Kit...

Страница 8: ...chimney use 30 firestop spacer Model F10FS30 2 Use one nail on opposite sides to hold firestop spacer in position Nail permanently using at least two 2 more 8d nails after chimney sections have been a...

Страница 9: ...ding flue pipe and locking outer stabi lizer section into place over the outer chimney pipe Position for proper clearance through framedopeningandnailstrapssecurely under tension in shear into place o...

Страница 10: ...ng tabs are firmly engaged 4 PullupslightlyonCTDtoensurelockingjoint has firmly engaged Using a FTF13 CT1 Chase Termination Refer to specific installation instructions in cluded with FTF13 CT1 chase t...

Страница 11: ...is 15 6 higher with offsets The maximum height for the system is 80 To determine the number of chimney sections andchimneycomponentsrequired followthese steps 1 Determine the total vertical height of...

Страница 12: ...hes Feet Inches 12 18 36 MM M 461 38 5 0 1 13 11722 11 72 465 38 9 2 0 13 11824 11 82 471 39 3 1 1 13 11976 11 98 479 39 11 0 0 14 12179 12 18 489 40 9 1 0 14 12433 12 43 495 41 3 0 1 14 12586 12 59 4...

Страница 13: ...2178 45 87 1 0 0 3 1 1149 2223 46 89 1 0 0 1 2 1175 2261 48 91 1 0 2 0 2 1226 2324 49 94 1 0 1 5 0 1257 2400 51 97 1 0 1 1 2 1302 2483 54 103 1 0 0 2 2 1378 2616 55 104 1 0 0 0 3 1403 2654 56 106 1 0...

Страница 14: ...E OUTSIDE AIR IS 50 FEET ABOVE THE HEARTH PROVING THE AIR INLET IS TERMI NATED A MINIMUM OF THREE 3 FEET BE LOW THE CHIMNEY CAP LEVEL Note Combustion air inlet ducts must not terminate in attic space...

Страница 15: ...surface of the indentation The refrac torymaterialisverythininthisareaandiseasily removed Once a small hole has been made continue tapping until you have reached suffi cientdiameterforthegaslinetofit...

Страница 16: ...ick must this material be Using the k formula Desired k value of desired Min Thickness Required material per inch x of listed Thickness k value of listed material material per inch TM inches kM x T1 8...

Страница 17: ...0 2 Offset Return Package 30 63L24 FTF13 ES30 INSTALLATION COMPONENTS The following items are available for use in the installation of this appliance The sum of all R values is 70 10 068 5825 1 4505 T...

Страница 18: ...9 FTF13 12 63L20 FTF13 18 Chimney Section 63L21 FTF13 36 63L40 F10F6 Flashing 63L41 F10F12 Round Termination 63L44 FTF13 CTD Firestop Spacer Flat 63L36 F10FS 2 INSTALLATION COMPONENTS Storm Collar 63L...

Страница 19: ...NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 19...

Страница 20: ...ges at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S...

Отзывы: