After having selected the final mounting position of the appliance, taking 

into account the site requirements as specified in Section 8 of these instruc-

tions, the integrity of the wall, and the feasibility of the proposed supply  

pipe routing, the firebox of appliance may be secured to the wall.

To ensure customer safety, be sure to design the installation so that the 

strength of both the wall and any wall fixings used are sufficient. Lennox 

Hearth Products assumes no responsibility for injuries and damages that 

may occur due to improper installation or handling.

The appliance should not be installed until all dry wall sanding and wall 

painting has been completed.

11.0 MOUNTING THE APPLIANCE

Non-concealed gas connections may be made using the entry points 

on the base of the firebox. A concealed gas connection may be made 

using the knockout hole in the center back of the firebox. Select the most 

appropriate entry point and knock out the relevant hole.

If a concealed gas connection is to be made, the supply pipe should always 

be sleeved through walls and floors using the shortest possible route. 

For concealed supply pipe routing, pipes must (where possible) be ver-

tical and providing there is sufficient wall thickness available, they should 

be placed in pipe chases. Horizontal pipe runs should be avoided where 

possible.  Prior to chasing a solid wall, an inspection should be made 

to note the proximity of any cables/sockets outlets which may already 

be buried. Pipes must be secured using suitable clips and protected 

against corrosion. Ideally factory finished protected pipe-work and fittings 

should be used. Joints should be kept to a minimum and compression 

fittings must not be used. The pipe-work installation must be tested for 

soundness before any protection is applied and/or the pipe-work and 

fittings are buried.

      WARNING 

The wall where the appliance is to be installed must 

be capable of long-term support of the total load of 

the appliance. Measures should also be taken to 

ensure sufficient strength to withstand the force of 

earthquakes, vibration and other external forces.

Incorrect installation can cause the appliance to fall from the wall and 

cause injury. Do not block the ventilation holes of the appliance. The 

wall onto which the appliance is installed must be flat. Install only on a 

vertical surface. Avoid sloped surfaces. 

Installation onto anything other 

than a vertical wall may result in fire, damage or injury.

A full size fitting template is supplied to assist with wall mounting. 

Mark the positions shown as “Fixing Points” on the wall.  If the appli-

ance is to be mounted on the inner leaf of a conventional cavity wall, 

or a solid wall, drill four holes using a 5/16" masonry bit, to a depth of 

1-11/16". Insert the wall plugs provided.

If the appliance is to be mounted on a dry lined wall or a timber framed 

construction wall then special cavity screw fixings will be required which 

are not supplied with this product. These should be constructed from 

metal and not plastic.

If a concealed gas connection is to be made ensure the gas supply pipe 

is in it’s final position and can enter the appliance in the correct position 

when the appliance is hung on the wall.

Figure 2 - Wall Fixing Template

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

WARNING

CLEARANCES FROM COMBUSTIBLE MATERIALS

F860041/A

The following clearances must be maintained at all times.
Failure to do so may result in the risk of a fire.
For full information refer to the instruction manual 
provided with the heater.

Note : Zero clearance from bottom of heater frame 
required for hard combustible floors. Minimum 4” 
clearance required to rugs or any fabric floor 
coverings. REFER TO INSTRUCTION MANUAL

IMPORTANT : Fabrics, curtains and drapes are not 
permited above the heater at any distance and within 
20” of the heater sides. No combustible shelves of any 
size are permitted above the heater.

Clearance to 
combustible 
sidewalls 4” 
(both sides)

Clearance to combustible ceiling 
32” measured from top of appliance 
glass panel

Clearance in 
front of 
heater 20”

F860041/A

Deben mantenerse en todo momento los siguientes espacios 
libres. El no hacerlo puede causar un riesgo de incendio. 
Consulte el manual de instrucciones suministrado con este 
aparato para obtener información completa.

Nota: No se requiere espacio libre desde el borde inferior del 
marco del calentador en caso de pisos combustibles duros. 
Se requiere un espacio mínimo de 4” entre el calentador y 
cualquier alfombra, moqueta o revestimiento de suelo de 
tela. CONSULTE EL MANUAL DE INSTRUCCIONES.

IMPORTANTE: No se permite la colocación de telas, cortinas y 

similares por encima del calentador a cualquier distancia, ni a 

una distancia de 20” de los laterales del calentador. No se 

permiten estantes combustibles de cualquier tamaño por 

encima del calentador.

Espacio hasta
paredeslaterales
combustibles
4” (ambos lados)

El espacio de 32” hasta un techo 
combustible se mide desde el borde 
superior del panel de vidrio del aparato

Espacio libre
delante del
calentador 20”

ADVERTENCIA

ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES

FIREBO

X OUTLINE

C

ONT

ORNO DE LA CAMARA DE C

OMBUSTION

POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL

COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED

PIERCE TEMPLATE TO MARK HOLE POSITION ON WALL X 4

CENTRE LINE

17-3/16”

 (437mm)

CONCEALED

GAS INLET

ENTRADA DE

GAS OCULTA

1/2”

(13mm)

16” (406mm)

FIXING POINTS

Scandium

FIXING POINTS

PUNTOS DE SUJECION

PERFORE LA PLANTILLA PARA MARCAR LA POSICION DE LOS 4 TALADROS EN LA PARED

PUNTOS DE SUJECION

LINEA DE CENTRO

WALL MOUNTED VENT FREE FITTING TEMPLATE

PLANTILLA PARA LA INSTALACION DE CHIMENEAS DE PARED SIN SALIDA DE HUMOS

IMPORTANT

THIS APPLIANCE IS TO BE WALL HUNG ONLY. 

DO NOT RECESS OR INSET ANY PART OF THE APPLIANCE.

THIS TEMPLATE IS FOR THE MARKING OF FIXING POINTS ONLY.

 DO NOT INSTALL THE APPLIANCE WITH THIS TEMPLATE IN PLACE.

IMPORTANTE

ESTE APARATO UNICAMENTE DEBE SER COLGADO EN UNA PARED.

NO EMPOTRE NINGUN ELEMENTO DE ESTE APARATO.

ESTA PLANTILLA SIRVE UNICAMENTE PARA MARCAR LOS PUNTOS DE FIJACION.

RETIRE LA PLANTILLA ANTES DE COLOCAR LE APARATO.

APPLIANCE OUTLINE 

 

C

ONT

ORNO DE LA AP

ARA

TO

DO 005855/0 - ISSUE A

FocalPointFires Single   24/04/08

DO 005855/0 

Lennox L40 Scandium fitting template

Ref. Paul West - Focal Point Fires. Any problems please call 01202 588629

Artwork Size: W1055 x H530

Содержание Scandium-LP

Страница 1: ...for use with other gases Lennox vent free appliances are designed for use as a supplemental heater They are not intended for continuous use as a primary heat source P N 850 055M REV F 05 2009 In the...

Страница 2: ...at elevations above 4500 feet nuisance pilot outages may occur Ensure that the heater is clean when operating Excessive dust accumulation on the burner will increase the amount of carbon monoxide for...

Страница 3: ...21 0 Servicing 12 22 0 Servicing The Burner 12 23 0 Pilot Assembly 12 24 0 Catalysts 13 25 0 Testing For Firebox Leakage 13 26 0 Cleaning 13 27 0 Lighting Instructions Turning Off Appliance 14 28 0 Tr...

Страница 4: ...of 527 CMR 30 upon sale of the unit This Lennox Hearth Products Unvented Gas Room Heater is certified by OMNI Test Laboratories Inc to ANSI Z21 11 2 standard 5 0 UNPACKING THE APPLIANCE Remove the st...

Страница 5: ...grills between rooms Example 24 L x 16 W x 8 H 3072 ft3 2 Dividethevolumeofspaceby50ft3 todeterminethemaximumBTU Hr the space can support ______ volume of space ft3 50 ft3 Maximum BTU Hr the space ca...

Страница 6: ...appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to carry the weight of the appliance must be confirmed It is important i...

Страница 7: ...enter the appliance in the correct position when the appliance is hung on the wall Figure 2 Wall Fixing Template NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE WARNING CLEARANCES FROM COMBUSTIBLE MATER...

Страница 8: ...gas room heater to the gas supply Consult all local codes The installer must provide an ANSI approved manual shut off valve flex connector and 3 8 NPT fitting A flex gas line kit with shut off valve...

Страница 9: ...gure 7 for burner manifold and regulator inlet setting pressures The pressure should be checked with the gas heater burning and the control set to high flame The pressure test points are located on th...

Страница 10: ...The screws should be finger tightened until all side and top frame pieces are assembled and aligned At that point tighten the screws in 1 4 turn increments until frame pieces are firmly positioned an...

Страница 11: ...shown Insert the M6 retain ing screws in the sides of the firebox and ensure they are unscrewed approximately 1 8 so the keyhole shaped holes may engage and the sides can be hooked on Note Frontframe...

Страница 12: ...y change to this heater or its controls can be dangerous First remove the front Glass facia as described in Section 18 0 only in reverse remove the valve cover 4 screws and disconnect the gas con nect...

Страница 13: ...off and a smoke pellet or match introduced at the base of the fire underneath the burner tray Large quantities of smoke will emerge from the top of the appliance but none should emerge from the joint...

Страница 14: ...ide behind the burner Figure 20 7 Depress control knob in and turn counter clockwise to the SPARK position Figure 19 and hold there for a few seconds Note If you are running the heater for the first t...

Страница 15: ...m with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY...

Страница 16: ...arco del calentador en caso de pisos combustibles duros Se requiere un espacio m nimo de 4 entre el calentador y cualquier alfombra moqueta o revestimiento de suelo de tela CONSULTE EL MANUAL DE INSTR...

Страница 17: ...emoval Remove the four 4 screws indicated then lift door off 4 off burner installation positions Figure 21 WARNING Failure to position the parts in accordance with these diagrams orfailuretouseonlypar...