Lennox Scandium-LP Скачать руководство пользователя страница 3

.0 GENERAL INFORMATION

This appliance is a high efficiency, unvented, flame effect gas heater.  It 

provides radiant and convected warmth both efficiently and safely utilizing 

the latest type catalytic convertor burner technology. The appliance does 

not require a flue system of any type as the catalytic converter cleans 

the flue products to provide a complete combustion system, which is 

intrinsically safe.

3.0 PACKAGING LIST

Quantity       Description

     1 

     Firebox And Burner Assembly

     1  

     Installation And Operation Instructions

     1 

     Glass Facia Panel Assembly

   1 

     Fitting Template

   1 

     Screw And Wall Plug Pack

   1 

     Rubber Grommet 

4.0 APPLIANCE SPECIFICATIONS

CONGRATULATIONS!

When you purchased your new gas fireplace, you joined the 
ranks of thousands of individuals whose answer to their home 
heating needs reflects their concern for aesthetics, efficiency 
and our environment. We extend our continued support to help 
you achieve the maximum benefit and enjoyment available from 
your new gas fireplace.

Thank you for selecting a Lennox Hearth Products gas fireplace 
as the answer to your home heating needs.

TABLE OF CONTENTS

Section  Contents       

                        Page No.

  1.0 

Safety And Warning Information . . . . . . . . . . . . .  2

  2.0 

General Information . . . . . . . . . . . . . . . . . . . . . . .  3

  3.0 

Packaging List . . . . . . . . . . . . . . . . . . . . . . . . . . .  3

  4.0 

Appliance Specifications . . . . . . . . . . . . . . . . . . .  3

  5.0 

Unpacking the Appliance . . . . . . . . . . . . . . . . . . .  4

  6.0 

Burn-in Period . . . . . . . . . . . . . . . . . . . . . . . . . . .  4

  7.0 

Codes, Massachusetts and New York . . . . . . . . .  4

  8.0 

Combustion And Ventilation Air. . . . . . . . . . . . . .  5

  9.0 

Site Requirements . . . . . . . . . . . . . . . . . . . . . . . .  6

  10.0  Preparing The Appliance . . . . . . . . . . . . . . . . . . .  6

  11.0  Mounting The Appliance . . . . . . . . . . . . . . . . . . .  7 

  12.0  Checking The Burner . . . . . . . . . . . . . . . . . . . . . .  8

  13.0  Connecting A Gas Line  . . . . . . . . . . . . . . . . . . . .  8

  14.0  Checking The Gas Connections . . . . . . . . . . . . . .  9

  15.0  Gas Pressure Check . . . . . . . . . . . . . . . . . . . . . . .  9 

  16.0  Spark Gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10

  17.0  Assembly of the Glass Facia  . . . . . . . . . . . . . . . .  10 

  18.0  Fitting the Glass Facia . . . . . . . . . . . . . . . . . . . . .  11 

  19.0  Fitting the side panels . . . . . . . . . . . . . . . . . . . . .  11

  20.0  Briefing The Customer. . . . . . . . . . . . . . . . . . . . .  12

  21.0  Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12

  22.0  Servicing The Burner. . . . . . . . . . . . . . . . . . . . . .  12

  23.0  Pilot Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . .  12

  24.0  Catalysts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13

  25.0  Testing For Firebox Leakage  . . . . . . . . . . . . . . . .  13

  26.0  Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13

  27.0  Lighting Instructions & Turning Off Appliance . . .  14

  28.0  Troubleshooting Guide. . . . . . . . . . . . . . . . . . . . .  15

  29.0  Replacement Parts List . . . . . . . . . . . . . . . . . . . .  16 

  30.0  Positioning Of Field Assembled Parts . . . . . . . . .  17

  31.0  Specifications / Gas Entry Point Dimensions. . . .  18

  32.0  Product Reference Information . . . . . . . . . . . . . .  20

These heaters are fitted with a specially designed pilot utilizing an oxygen 

depletion sensor (ODS) which responds to the amount of oxygen avail-

able in the room and shuts the heater off before the oxygen level drops 

below 18%. It must not be adjusted or put out of operation. If replaced 

then manufacturers original parts must be used. The pilot can be relit 

only when fresh air is available. Refer to the Combustion and Ventilation 

Air section.

The appliance is designed to fit various types of situations as listed in 

the installation requirements.  

This appliance is factory set for operation on the gas type, and at the 

pressure stated on the appliance rating plate.

Read all these instructions before commencing installation. All instructions 

must be left in the possession of the user for safekeeping.

Gas Type

Natural Gas

Propane Gas

Gas inlet pressure

 

Max.

 

Min.

10.5” w.c.

6” w.c.

13” w.c.

11” w.c.

Regulator Pressure Setting

5” w.c.

10” w.c.

Max Energy Input

11,950 BTU/hour

10,35 BTU/hour

Min Energy Input

6,80 BTU/hour

6,80 BTU/hour

Pilot Energy Input

560 BTU/hour

560 BTU/hour

Burner Pressure

 

High

(Manifold)

 

Low

.4” w.c. 

0.8” w.c. 

5.5” w.c.

.4” w.c.

Main burner flow restrictor

(burner orifice)

.0 mm (0.079”)

1.45mm (0.057”)

Oxypilot

SIT/Bray 908

SIT/Bray 984

Gas Inlet Connection

3/8” NPT at regulator

3/8” NPT at regulator

Ignition

Piezo spark

Piezo spark

Spark Gap

1/8” - 3/16”

1/8” - 3/16”

Please see Data Plate affixed to appliance for current data. This appliance is for use 

only with the gas type, and at the pressure stated on the appliance Data Plate.

Table 1

3

Содержание Scandium-LP

Страница 1: ...for use with other gases Lennox vent free appliances are designed for use as a supplemental heater They are not intended for continuous use as a primary heat source P N 850 055M REV F 05 2009 In the...

Страница 2: ...at elevations above 4500 feet nuisance pilot outages may occur Ensure that the heater is clean when operating Excessive dust accumulation on the burner will increase the amount of carbon monoxide for...

Страница 3: ...21 0 Servicing 12 22 0 Servicing The Burner 12 23 0 Pilot Assembly 12 24 0 Catalysts 13 25 0 Testing For Firebox Leakage 13 26 0 Cleaning 13 27 0 Lighting Instructions Turning Off Appliance 14 28 0 Tr...

Страница 4: ...of 527 CMR 30 upon sale of the unit This Lennox Hearth Products Unvented Gas Room Heater is certified by OMNI Test Laboratories Inc to ANSI Z21 11 2 standard 5 0 UNPACKING THE APPLIANCE Remove the st...

Страница 5: ...grills between rooms Example 24 L x 16 W x 8 H 3072 ft3 2 Dividethevolumeofspaceby50ft3 todeterminethemaximumBTU Hr the space can support ______ volume of space ft3 50 ft3 Maximum BTU Hr the space ca...

Страница 6: ...appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to carry the weight of the appliance must be confirmed It is important i...

Страница 7: ...enter the appliance in the correct position when the appliance is hung on the wall Figure 2 Wall Fixing Template NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE WARNING CLEARANCES FROM COMBUSTIBLE MATER...

Страница 8: ...gas room heater to the gas supply Consult all local codes The installer must provide an ANSI approved manual shut off valve flex connector and 3 8 NPT fitting A flex gas line kit with shut off valve...

Страница 9: ...gure 7 for burner manifold and regulator inlet setting pressures The pressure should be checked with the gas heater burning and the control set to high flame The pressure test points are located on th...

Страница 10: ...The screws should be finger tightened until all side and top frame pieces are assembled and aligned At that point tighten the screws in 1 4 turn increments until frame pieces are firmly positioned an...

Страница 11: ...shown Insert the M6 retain ing screws in the sides of the firebox and ensure they are unscrewed approximately 1 8 so the keyhole shaped holes may engage and the sides can be hooked on Note Frontframe...

Страница 12: ...y change to this heater or its controls can be dangerous First remove the front Glass facia as described in Section 18 0 only in reverse remove the valve cover 4 screws and disconnect the gas con nect...

Страница 13: ...off and a smoke pellet or match introduced at the base of the fire underneath the burner tray Large quantities of smoke will emerge from the top of the appliance but none should emerge from the joint...

Страница 14: ...ide behind the burner Figure 20 7 Depress control knob in and turn counter clockwise to the SPARK position Figure 19 and hold there for a few seconds Note If you are running the heater for the first t...

Страница 15: ...m with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY...

Страница 16: ...arco del calentador en caso de pisos combustibles duros Se requiere un espacio m nimo de 4 entre el calentador y cualquier alfombra moqueta o revestimiento de suelo de tela CONSULTE EL MANUAL DE INSTR...

Страница 17: ...emoval Remove the four 4 screws indicated then lift door off 4 off burner installation positions Figure 21 WARNING Failure to position the parts in accordance with these diagrams orfailuretouseonlypar...

Страница 18: ...ECIFICATIONS 20 13 16 10 1 4 41 1 2 27 11 16 18 5 8 5 9 16 7 1 8 30 1 16 16 Product Reference Information Cat No Model Ship Wt Ship Volume H6065 Scandium NG 80 7 lb 12 9 cu ft H6071 Scandium LP 80 7 l...

Страница 19: ...are converted from millimeters and are rounded to the nearest 1 16 KEY D1 Distance from mounting surface to rear entry point D2 Distance from mounting surface to center of side entry point D3 Distanc...

Страница 20: ...r Normally all parts should be ordered through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following inform...