Lennox Scandium-LP Скачать руководство пользователя страница 16

16

9.0 REPLACEMENT PARTS - SCANDIUM™

1

2

7

5

6

8

9a

Replacement Parts

Item #

Cat.No.

Description

1

H6057

Glass door assembly

2

H6060

Catalyst

3

H6061

Pilot assembly, Natural Gas

4

H6999

Pilot assembly, Propane Gas

5

H6058

Burner Assembly, Natural Gas

6

H7012

Burner Assembly, Propane Gas

7

H6062

Catalyst Gasket

8

H7037

3 Pc. Frame Assembly

9a

H7002

Ball Knob

9b

H7041

Knob Spindle

10

H7006

Hardware Kit 

u

11

H6068

Decorative Glass Facia

12

H7321

Fitting Template

Optional Parts

13

93L32

FFGC   Flex Gas Line Kit

9b

11

12

Hardware kits consists of the following:

 

6 ea. No.8 x 5/16 Screw Pozi Pan Head

 

6 ea. M6 x 12 Screw Pozi Pan Head BZP

 

6 ea. M4 x 12 Screw Pozi Pan Head Black

 

1 ea. Rubber Grommet

 

4 ea. Wall Plug

 

4 ea. Wall Fixing Screws

 

2 ea. Ceramic bracket

 

2 ea. Clevis Pin

See ordering instructions on Page 20

WARNING

CLEARANCES FROM COMBUSTIBLE MATERIALS

F860041/A

The following clearances must be maintained at all times.
Failure to do so may result in the risk of a fire.
For full information refer to the instruction manual 
provided with the heater.

Note : Zero clearance from bottom of heater frame 
required for hard combustible floors. Minimum 4” 
clearance required to rugs or any fabric floor 
coverings. REFER TO INSTRUCTION MANUAL

IMPORTANT : Fabrics, curtains and drapes are not 
permited above the heater at any distance and within 
20” of the heater sides. No combustible shelves of any 
size are permitted above the heater.

Clearance to 
combustible 
sidewalls 4” 
(both sides)

Clearance to combustible ceiling 
32” measured from top of appliance 
glass panel

Clearance in 
front of 
heater 20”

F860041/A

Deben mantenerse en todo momento los siguientes espacios 
libres. El no hacerlo puede causar un riesgo de incendio. 
Consulte el manual de instrucciones suministrado con este 
aparato para obtener información completa.

Nota: No se requiere espacio libre desde el borde inferior del 
marco del calentador en caso de pisos combustibles duros. 
Se requiere un espacio mínimo de 4” entre el calentador y 
cualquier alfombra, moqueta o revestimiento de suelo de 
tela. CONSULTE EL MANUAL DE INSTRUCCIONES.

IMPORTANTE: No se permite la colocación de telas, cortinas y 

similares por encima del calentador a cualquier distancia, ni a 

una distancia de 20” de los laterales del calentador. No se 

permiten estantes combustibles de cualquier tamaño por 

encima del calentador.

Espacio hasta
paredeslaterales
combustibles
4” (ambos lados)

El espacio de 32” hasta un techo 
combustible se mide desde el borde 
superior del panel de vidrio del aparato

Espacio libre
delante del
calentador 20”

ADVERTENCIA

ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES

FIREBO

X OUTLINE

C

ONT

ORNO DE LA CAMARA DE C

OMBUSTION

POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL

COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED

PIERCE TEMPLATE TO MARK HOLE POSITION ON WALL X 4

CENTRE LINE

17-3/16”

 (437mm)

CONCEALED

GAS INLET

ENTRADA DE

GAS OCULTA

1/2”

(13mm)

16” (406mm)

FIXING POINTS

Scandium

FIXING POINTS

PUNTOS DE SUJECION

PERFORE LA PLANTILLA PARA MARCAR LA POSICION DE LOS 4 TALADROS EN LA PARED

PUNTOS DE SUJECION

LINEA DE CENTRO

WALL MOUNTED VENT FREE FITTING TEMPLATE

PLANTILLA PARA LA INSTALACION DE CHIMENEAS DE PARED SIN SALIDA DE HUMOS

IMPORTANT

THIS APPLIANCE IS TO BE WALL HUNG ONLY. 

DO NOT RECESS OR INSET ANY PART OF THE APPLIANCE.

THIS TEMPLATE IS FOR THE MARKING OF FIXING POINTS ONLY.

 DO NOT INSTALL THE APPLIANCE WITH THIS TEMPLATE IN PLACE.

IMPORTANTE

ESTE APARATO UNICAMENTE DEBE SER COLGADO EN UNA PARED.

NO EMPOTRE NINGUN ELEMENTO DE ESTE APARATO.

ESTA PLANTILLA SIRVE UNICAMENTE PARA MARCAR LOS PUNTOS DE FIJACION.

RETIRE LA PLANTILLA ANTES DE COLOCAR LE APARATO.

APPLIANCE OUTLINE 

 

C

ONT

ORNO DE LA AP

ARA

TO

DO 005855/0 - ISSUE A

FocalPointFires Single   24/04/08

DO 005855/0 

Lennox L40 Scandium fitting template

Ref. Paul West - Focal Point Fires. Any problems please call 01202 588629

Artwork Size: W1055 x H530

5

4

10

Hardware

4

3

13

Содержание Scandium-LP

Страница 1: ...for use with other gases Lennox vent free appliances are designed for use as a supplemental heater They are not intended for continuous use as a primary heat source P N 850 055M REV F 05 2009 In the...

Страница 2: ...at elevations above 4500 feet nuisance pilot outages may occur Ensure that the heater is clean when operating Excessive dust accumulation on the burner will increase the amount of carbon monoxide for...

Страница 3: ...21 0 Servicing 12 22 0 Servicing The Burner 12 23 0 Pilot Assembly 12 24 0 Catalysts 13 25 0 Testing For Firebox Leakage 13 26 0 Cleaning 13 27 0 Lighting Instructions Turning Off Appliance 14 28 0 Tr...

Страница 4: ...of 527 CMR 30 upon sale of the unit This Lennox Hearth Products Unvented Gas Room Heater is certified by OMNI Test Laboratories Inc to ANSI Z21 11 2 standard 5 0 UNPACKING THE APPLIANCE Remove the st...

Страница 5: ...grills between rooms Example 24 L x 16 W x 8 H 3072 ft3 2 Dividethevolumeofspaceby50ft3 todeterminethemaximumBTU Hr the space can support ______ volume of space ft3 50 ft3 Maximum BTU Hr the space ca...

Страница 6: ...appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to carry the weight of the appliance must be confirmed It is important i...

Страница 7: ...enter the appliance in the correct position when the appliance is hung on the wall Figure 2 Wall Fixing Template NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE WARNING CLEARANCES FROM COMBUSTIBLE MATER...

Страница 8: ...gas room heater to the gas supply Consult all local codes The installer must provide an ANSI approved manual shut off valve flex connector and 3 8 NPT fitting A flex gas line kit with shut off valve...

Страница 9: ...gure 7 for burner manifold and regulator inlet setting pressures The pressure should be checked with the gas heater burning and the control set to high flame The pressure test points are located on th...

Страница 10: ...The screws should be finger tightened until all side and top frame pieces are assembled and aligned At that point tighten the screws in 1 4 turn increments until frame pieces are firmly positioned an...

Страница 11: ...shown Insert the M6 retain ing screws in the sides of the firebox and ensure they are unscrewed approximately 1 8 so the keyhole shaped holes may engage and the sides can be hooked on Note Frontframe...

Страница 12: ...y change to this heater or its controls can be dangerous First remove the front Glass facia as described in Section 18 0 only in reverse remove the valve cover 4 screws and disconnect the gas con nect...

Страница 13: ...off and a smoke pellet or match introduced at the base of the fire underneath the burner tray Large quantities of smoke will emerge from the top of the appliance but none should emerge from the joint...

Страница 14: ...ide behind the burner Figure 20 7 Depress control knob in and turn counter clockwise to the SPARK position Figure 19 and hold there for a few seconds Note If you are running the heater for the first t...

Страница 15: ...m with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY...

Страница 16: ...arco del calentador en caso de pisos combustibles duros Se requiere un espacio m nimo de 4 entre el calentador y cualquier alfombra moqueta o revestimiento de suelo de tela CONSULTE EL MANUAL DE INSTR...

Страница 17: ...emoval Remove the four 4 screws indicated then lift door off 4 off burner installation positions Figure 21 WARNING Failure to position the parts in accordance with these diagrams orfailuretouseonlypar...

Страница 18: ...ECIFICATIONS 20 13 16 10 1 4 41 1 2 27 11 16 18 5 8 5 9 16 7 1 8 30 1 16 16 Product Reference Information Cat No Model Ship Wt Ship Volume H6065 Scandium NG 80 7 lb 12 9 cu ft H6071 Scandium LP 80 7 l...

Страница 19: ...are converted from millimeters and are rounded to the nearest 1 16 KEY D1 Distance from mounting surface to rear entry point D2 Distance from mounting surface to center of side entry point D3 Distanc...

Страница 20: ...r Normally all parts should be ordered through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following inform...

Отзывы: