9.Troubleshooting
9.1 Display board
Thi s indicator illuminates whe n the air conditioner i s in AUTO operation.
AU TO indicator
DE FROST indicator (F or Cooling & H eating mo dels only)
Thi s indicator illuminates whe n the air conditioner starts defrostin g automati cally or
when the warm air control fea ture is activated in he ating oper ation.
1
22
3
4
5
1
22
3
4
Displays the te mperature settings when the air condition er is operational.
This indicator fl ashe s after power is on and illuminate s when the unit is in operation.
This indicator il luminates when TIMER is set ON/OFF.
OPERATION in dicator
TIMER indicator
TEMPERATUR E indicator
5
Signal receptor
9.2 For all heat pump model
r
Extinguish
☆
Flash at 5Hz
Failure phenomenon
Operation lamp
Timer lamp
Indoor fan speed has been out of control for over 1 minute
☆
X
Indoor room temp. or evaporator sensor is open circuit or short circuit
☆
On
Over current protection of the compressor occurs 4 times
X
☆
EEROM error
On
☆
No over-zero signal
☆
☆
Содержание GCM07N
Страница 3: ...2 1 Features 1 1Compact design 1 2High efficiency and quiet operation 1 3A class energy level ...
Страница 6: ...5 3 Dimensions 3 1 Indoor unit GCM 07N GHM07N GCM09N GHM09N 3 2 Indoor unit GCM 12N GHM12N ...
Страница 7: ...6 3 2 Indoor unit GCM 18N GHM18N ...
Страница 8: ...7 3 4 Outdoor unit GCM 07N GHM07N 3 5 Outdoor unit GCM 09N1 GHM09N GCM12N GHM12N ...
Страница 9: ...8 GCM 18N GHM18N 12 5 ...
Страница 10: ...9 4 Refrigeration cycle diagram ...
Страница 24: ...23 7 2 2 Heating cooling 7 2 2 1 GHM07N GHM09N GHM12N I NDO OR UNI T O UTD OO R UNI T ...
Страница 30: ...29 T 0 High ...