TABLE 15
G61MPVT−60C−090 BLOWER MOTOR PERFORMANCE (LESS FILTER)
0.0" to 0.8" w.g. (0 through 200 Pa) External Static Pressure Range
Factory Settings: Heating Speed − 2; Cooling Speed − 4; Speed Adjust − NORM.
Return Air Options: Bottom; both sides; or bottom and one side.
ADJUST"
Switch
Positions
Speed Switch Positions
Second Stage HEAT" Speed
Second Stage COOL" Speed
1
2
3
4
1
2
3
4
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
+
1500
710
1675
790
1880
885
2090
985
1605
760
1710
805
1925
910
2165 1020
NORM
1355
640
1545
730
1720
810
1900
895
1440
680
1560
735
1755
825
1960
925
1194
565
1365
645
1540
730
1695
800
1275
600
1380
650
1590
750
1755
830
ADJUST"
Switch
Positions
First Stage HEAT" Speed
First Stage COOL" Speed
1
2
3
4
1
2
3
4
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
+
1360
640
1560
735
1730
815
1910
900
1105
520
1185
560
1355
640
1545
730
NORM
1220
575
1405
665
1585
750
1740
820
995
470
1080
510
1205
570
1345
635
1105
520
1235
585
1410
665
1570
740
890
420
960
455
1090
515
1215
575
NOTES − The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately
91%
of the same second stage HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately 70
%
of the same second stage COOL speed position.
Continuous Fan Only speed is approximately
38%
of the same second stage COOL speed position − minimum 500 cfm (235 L/s).
TABLE 16
G61MPVT−60C−090 BLOWER MOTOR PERFORMANCE (LESS FILTER)
0.0" to 0.8" w.g. (0 through 200 Pa) External Static Pressure Range
Factory Settings: Heating Speed − 2; Cooling Speed − 4; Speed Adjust − NORM.
Return Air Options: Single side return air − Bold volumes require field−fabricated transition to accommodate
20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable air filter in order to maintain proper air velocity across the filter.
ADJUST"
Switch
Positions
Speed Switch Positions
Second Stage HEAT" Speed
Second Stage COOL" Speed
1
2
3
4
1
2
3
4
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
+
1450
685
1640
775
1820
860
2055
970
1575
745
1690
795
1895
895
2135 1005
NORM
1320
625
1510
710
1700
800
1870
880
1405
665
1530
720
1735
820
1935
910
1165
550
1320
625
1500
705
1665
785
1250
590
1355
640
1560
735
1735
820
ADJUST"
Switch
Positions
First Stage HEAT" Speed
First Stage COOL" Speed
1
2
3
4
1
2
3
4
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
+
1315
620
1510
715
1695
800
1875
885
1080
510
1160
545
1315
620
1490
705
NORM
1190
560
1365
645
1545
730
1715
810
985
465
1060
500
1185
560
1330
625
1075
510
1205
570
1370
645
1520
715
865
410
930
440
1065
500
1185
560
NOTES − The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately
91%
of the same second stage HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately 70
%
of the same second stage COOL speed position.
Continuous Fan Only speed is approximately
38%
of the same second stage COOL speed position − minimum 500 cfm (235 L/s).