53
•
It is strictly prohibited to supply gas to the circuit with pressure higher than 60mbar. Such pressures could cause the valve to break.
If pressure are higher than 60mbar, a pressure reducer must be installed at least 10 m away and no pressure stabiliser must be
fitted between the pressure reducer and the heater, but leaving the gas filter.
Condensate drain
WARNING: Do not forget to connect the condensate drain (No need to add a siphon). The condensates must
absolutely be drained at least 5 meters from the unit into an appropriate place/evacuation. The condensates
are corrosive and could damage the unit (or other parts of the installation) if they are not drained properly.
Supply sensor with PCH vertical: After installation of duct,
place the sensor in “running” position by pushing the metallic
support.
GAS BURNER
GAS BURNER