Form No. PDS FE4A.18.1

 

COMMUNICATING VARIABLE 
SPEED FAN COIL PURON® 
REFRIGERANT

 

MODEL FE4A

 

Sizes 002 thru 006

 

A02332

 

FE4A

PREMIUM ENVIRONMENTALLY SOUND

FAN COIL

 

The FE4A is the premium air handler combining the proven 
technology of Bryant fan coils with the environmentally sound 
refrigerant, Puron®. The FE4A achieves an operation 
advantage because the ECM (Electronically Commutated 
Motor) combined with a Quantum Plus heat pump with Puron is 
highly efficient at all possible operating speeds, and delivers the 
precise amount of airflow desired over a wide range of duct 
static pressure conditions.

The FE4A comes with state of the art smart diagnostics 
capability. This enables faster troubleshooting providing ease of 
service and repair. The FE4A also provides a 4-wire hook up 
with matching outdoor unit and the Evolution Control. This 
makes installation simpler and a lot quicker than with 
conventional fan coils. The FE4A’s advanced technology allows 
the fan coil to self-configure with a matching outdoor unit and 
the Evolution Control, cutting down on installation time.

Other features homeowners appreciate are quiet operation of 
the FE4A, including the soft ramp up at the beginning of a 
heating or cooling cycle, and its soft ramp down when the duty 
cycle is complete. Annoying sounds from sudden changes in 
airflow are reduced for worry free comfort. When used in 
continuous fan mode, the FE4A can operate quietly at very low 
levels of airflow for gentle reduction of temperature differences 
between areas of the home and within each individual room 
from floor to ceiling. In addition, when used in conjunction with 
Bryant air cleaners, the FE4A provides continual cleansing of 
the air while quietly operating in continuous fan duty, for the best 
in indoor air quality.

The FE4A is loaded with other popular features. The 
Thermostatic Expansion Valve (TXV) reliably meters refrigerant 
at all operating conditions during cooling mode providing 
excellent compressor protection. Grooved copper tubing,  
louvered aluminum fins, and the large face areas of the FE4A 
refrigerant coils provide superior efficiency, for high SEER and 
HSPF performance. Robust, corrosion resistant and highly 
draining condensate pans provide for excellent condensate 
control. All components are protected within a rugged, 
prepainted metal cabinet lined with super thick, high density 
insulation and vapor barrier. The unit exterior features sweat 
refrigerant connections for simple leak free performance, 
multiple electrical entry for both high and low voltage service to 
simplify installation. Field-installed heaters are also available, 
ranging from 5-kw to 30-kw.

For the best in efficiency and Environmentally Sound operation, 
comfort, ease of installation and reliable performance, the FE4A 
can’t be beat.

Содержание FE4A

Страница 1: ...unds from sudden changes in airflow are reduced for worry free comfort When used in continuous fan mode the FE4A can operate quietly at very low levels of airflow for gentle reduction of temperature differences between areas of the home and within each individual room from floor to ceiling In addition when used in conjunction with Bryant air cleaners the FE4A provides continual cleansing of the ai...

Страница 2: ...igorous than Air Conditioning and Refrigeration Institute requirements Super thick insulation with vapor barrier Galvanized pre painted cabinet Installation flexible multipoise units Horizontal hanging provisions on cabinet Factory supplied cleanable and reusable filter Newly improved filter rack filter insulation added for an improved air seal No tools required to service filter 5 through 30 kw a...

Страница 3: ...NT Puron R 410A Refr Metering Device TXV Size 2 Ton 3 Ton 4 Ton 4 Ton COIL Type A Slope A A Rows Fins In 3 14 5 Face Area sq ft 3 46 3 46 5 93 7 42 MATCHES OUTDOOR UNIT SIZES Nominal Cooling Tons 1 5 2 2 5 3 2 2 5 3 3 5 2 5 3 3 5 4 3 3 5 4 5 FAN Upflow Downflow Horizontal Air Discharge CFM TON Nominal 350 MOTOR HP ECM 1 2 1 2 1 2 3 4 FILTER 21 1 2 x 16 3 8 21 1 2 x 18 7 8 21 1 2 x 18 7 8 21 1 2 x ...

Страница 4: ...H J In In In In In In In FE4A 002 42 11 16 17 5 8 15 3 4 15 5 8 10 3 4 003 53 7 16 21 1 8 19 1 4 19 1 8 19 3 16 19 005 53 7 16 21 1 8 19 1 4 19 1 8 19 1 2 006 59 3 16 24 11 16 22 3 4 22 11 16 25 1 4 34 1 16 A02321 DIMENSIONS ...

Страница 5: ...2322 DIMENSIONS Continued UNIT SIZE F G COIL CONFIGURATION SHIPPING WEIGHT In In SLOPE A Lb FE4A 002 18 9 16 18 1 4 Yes 135 003 26 15 16 27 1 2 Yes 150 005 27 1 4 26 15 16 Yes 172 006 32 15 16 32 5 8 Yes 207 ...

Страница 6: ...rflow at a rate that is requested by the Integrated System User Interface during Air Conditioning or Heat Pump Heating without electric heat modes The nominal airflow for both heating and cooling modes is 350 cfm ton nominal refrigeration size of the outdoor unit installed The airflow actually requested by the User Interface is modified by its internal algorithms for zoning comfort or efficiency c...

Страница 7: ... 018 024 030 036 625 650 675 850 1000 650 650 775 950 1050 825 900 1050 1125 1025 1125 1225 003 Heater Only 024 030 036 042 675 675 850 1025 1150 725 875 950 1075 1200 850 1100 1150 1300 1100 1150 1275 1400 005 Heater Only 030 036 042 048 675 850 1025 1150 1325 725 950 1075 1200 1325 850 1100 1150 1300 1400 1100 1150 1275 1400 1500 1400 1600 006 Heater Only 036 042 048 060 1050 1150 1150 1325 1650...

Страница 8: ...IC PRESSURE IN W C TOO HIGH RETURN STATIC PRESSURE DIFFICULT TO MAKE TRAP ACCEPTABLE RANGE A96052 Acceptable Duct Conditions For satisfactory operation specifically making dry secondary trap subject fan coils must be installed with duct systems which fall within the Acceptable Range illustrated above ...

Страница 9: ...0 36 29 40 25 23 0 25 35 39 42 32 36 38 29 32 33 26 28 29 22 23 23 1400 80 67 54 73 59 46 64 49 38 54 39 32 43 28 27 0 27 38 43 47 35 39 43 32 36 37 28 32 32 24 26 27 005 750 61 49 39 55 43 33 48 37 27 41 29 20 33 21 17 0 04 27 27 28 24 25 25 21 22 22 18 18 18 15 15 15 950 74 60 48 67 53 40 59 45 33 50 35 25 39 24 21 0 06 32 34 35 29 30 31 25 26 27 22 23 23 18 18 19 1150 89 72 57 79 63 48 69 52 38...

Страница 10: ...IONS OCTAVE BAND CENTER FREQUENCY CFM ESP 63 125 250 500 1000 2000 4000 FE4 002 400 0 25 63 0 59 0 55 0 52 0 50 0 48 0 44 0 600 0 25 64 7 60 7 56 7 53 7 51 7 49 7 45 7 800 0 25 66 0 62 0 58 0 55 0 53 0 51 0 47 0 1000 0 25 67 0 63 0 59 0 56 0 54 0 52 0 48 0 1200 0 25 67 8 63 8 59 8 56 8 54 8 52 8 48 8 1400 0 25 68 4 64 4 60 4 57 4 55 4 53 4 49 4 FE4 003 1400 0 25 63 0 59 0 55 0 52 0 50 0 48 0 44 0 ...

Страница 11: ...en that component or condition is used The remaining external static pressure will be available for the duct system HEATER KW ELEMENTS STATIC PRESSURE CORRECTION in wc Sizes 002 005 Size 006 0 0 02 03 5 1 01 02 8 10 2 0 0 9 15 3 02 03 20 4 04 06 18 24 30 6 06 10 MODEL FE4A CFM 400 600 800 1000 1200 1400 1600 1800 2000 002 0 020 0 044 0 048 0 072 0 100 003 0 020 0 035 0 051 0 070 0 092 005 0 035 0 ...

Страница 12: ... Cleaner The airflow sensor kit ensures the FE4 fan coil and electronic air cleaner work as a system REQUIRED USE This kit is required whenever an electronic air cleaner is used with an FE4 fan coil 7 Fan Coil Filter Kit shipped from factory with 12 fan coil framed filters These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the ...

Страница 13: ...8 230 1 4 3 5 4 14 15 003 208 230 1 4 3 5 4 14 15 005 208 230 1 4 3 5 4 14 15 006 208 230 1 6 8 8 5 14 15 HEATER PART NO KW 240V VOLTS PHASE STAGES KW OPERATING INTERNAL CIRCUIT PROTECTION FAN COIL SIZE USED WITH HEATING CAP 230V INTELLIGENT HEAT CAPABLE KW OPERATING KFCEH0501N05 5 230 1 5 None All 15 700 KFCEH0901N10 10 230 1 10 None All 31 400 KFCEH3001F15 15 230 1 5 15 Fuses All 47 100 5 10 15 ...

Страница 14: ... 53 5 8 6 10 10 50 60 54 87 9 6 8 3 None 18 8 20 8 32 0 34 5 8 8 10 10 35 35 83 85 KFCEH0901N10 10 7 5 1 None 36 2 40 0 53 8 58 5 6 6 10 10 60 60 78 80 KFCEH2601C10 10 7 5 1 Ckt Bkr 36 2 40 0 53 8 58 5 6 6 10 10 60 60 78 80 KFCEH3001F15 15 11 3 1 Fuse 54 2 59 9 36 2 40 0 18 1 20 0 76 3 83 4 53 8 58 5 22 7 25 0 4 4 6 6 10 10 8 8 10 10 10 10 80 90 60 60 25 25 88 89 78 80 75 76 KFCEH3101C15 15 11 3 1...

Страница 15: ... 15 ...

Страница 16: ...NSTALLATION INSTRUCTIONS Cancels New Form PDS FE4A 18 1 2003 Bryant Heating Cooling Systems 7310 W Morris St Indpls IN 46231 PRINTED IN U S A Catalog No 12FE 4A0 12 03 MATCHED SYSTEM ELECTRONIC AIR CLEANER VENTILATOR PLUS ZONE PERFECT PLUS EQUIPMENT CONTROLLER HEAT PUMP HUMIDIFIER FAN COIL A02295 ...

Отзывы: