ACCESSORY LIST
ACCESSORY KITS DESCRIPTION
SUGGESTED AND REQUIRED USE
1.
Disconnect Kit
The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely.
SUGGESTED USE: FE4 units with 3- through 10-kW electric resistance heaters and cooling controls.
2.
Downflow Conversion Kit
Fan coils are shipped from the factory for upflow or horizontal-left applications. Downflow conversion kits provide proper condensate water
drainage and support for the coil when used in downflow applications. Separate kits are available for slope coils and A-coils.
REQUIRED USE:
This kit must be used whenever FE4 fan coils are used in downflow applications.
3.
Downflow Base Kit
This kit is designed to provide a 1-in. minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides
a gap free seal with the floor.
REQUIRED USE:
This kit must be used whenever FE4 fan coils are used in downflow applications.
4.
Single-Point Wiring Kit
The single-point wiring kit acts as a jumper between L1 and L3 lugs, and between L2 and L4 lugs. This allows the installer to run 2 heavy-gage,
high-voltage wires into the fan coil rather than 4 light-gage, high-voltage wires.
SUGGESTED USE: FE4 fan coils with 15- and 20-kW fused heaters only.
5.
Air Cleaner 240-Volt Conversion Kit
The AIRA electronic air cleaner comes ready for 115-v operation.
REQUIRED USE:
This kit is required when running 240-volt circuit to air cleaner.
6.
Airflow Sensor Kit (Air Cleaner)
The airflow sensor kit ensures the FE4 fan coil and electronic air cleaner work as a system.
REQUIRED USE:
This kit is required whenever an electronic air cleaner is used with an FE4 fan coil.
7.
Fan Coil Filter
Kit shipped from factory with 12 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents
them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and in turn the efficiency of the system.
SUGGESTED USE: For replacing factory-supplied filters (same filters).
8.
Condensate Drain Trap Kit
This kit consists of 50 PVC condensate traps. Each trap is pre-formed and ready for field installation. This deep trap helps the system make and
hold proper condensate flow even during blower initiation.
SUGGESTED USE: FE4 fan coils.
9.
Downflow/Horizontal Conversion Gasket Kit
This kit provides the proper gasketing of units when applied in either a Downflow or Horizontal application.
REQUIRED USE:
F
E
4 fan coils.
ITEM
ACCESSORY PART NO.
FAN COIL SIZE USED WITH FE4A
Disconnect Kit
KFADK0201DSC
Cooling controls and heaters through 10-kW
Downflow Conversion Kit (Slope)
KFADC0201SLP
003
Downflow Conversion Kit (A-coil)
KFADC0401ACL
002, 005, 006
Downflow Base Kit
KFACB0201CFB
002
KFACB0301CFB
003, 005
KFACB0401CFB
006
Filter Kit (12 Pack)
KFAFK0212MED
002
KFAFK0312LRG
003, 005
KFAFK0412XXL
006
Single-Point Wiring Kit
KFASP0101SPK
Only with 15- and 20-kW Fused Heaters
Airflow Sensor Kit (Air Cleaner)
KEAAC0101AAA
All
Air Cleaner 240-Volt Conversion Kit
KEAVC0201240
All
PVC Condensate Drain Trap Kit (50 Pack)
KFAET0150ETK
All
Downflow/Horizontal Conversion Gasket Kit
KFAHD0101SLP
All