Indicating Light

Most heat pump thermostats have an amber light 

which indicates when the heat pump is operating in the 

emergency heat mode.

Temperature Indicator

The temperature indicator displays the actual room 

temperature.

Important System Information

•  Your system should never be operated without a clean 

air filter properly installed.

•  Return air and supply air registers should be free from 

restrictions or obstructions to allow full flow of air.

IF YOUR SYSTEM DOES NOT WORK, BEFORE 

REQUESTING A SERVICE CALL:

1.  Ensure thermostat is set below (cooling) or above 

(heating) room temperature and that the system lever 

is in the “COOL”, “HEAT” or “AUTO” position.

2. 

Inspect your return air filter: If it is dirty, your heat pump 

may not function properly.

3.  Check indoor and outdoor disconnect switches. 

Confirm circuit breakers are ON or that fuses have not 

blown. Reset breakers/replace fuses as necessary.

4.  Inspect the outdoor unit for clogged condenser coils, 

(grass cuttings, leaves, dirt, dust or lint). Ensure that 

branches, twigs or other debris are not obstructing the 

condenser fan.

IF YOUR SYSTEM STILL DOES NOT OPERATE, 

CONTACT YOUR SERVICING DEALER.

Be sure to describe the problem, and have the model and 

serial numbers of the equipment available.
If warranty replacement parts are required, the warranty 

must be processed through a qualified distribution location.

•  During the defrost cycle, you may notice steam rising 

from the outdoor unit. This is a normal occurrence. 

The thermostat may engage auxiliary heat during the 

defrost cycle to satisfy a heating demand; however, 

the unit will run to normal operation at the conclusion 

of the defrost cycle.

In case of extended power outage...

If the outdoor temperature is below 50°F and power to your 

outdoor unit has been interrupted for one hour or longer, 

observe the following when restoring power to your heat 

pump system.
•  Set the room thermostat selector to the “Emergency 

Heat” setting to obtain temporary heat for a minimum 

of 6 hours. This will allow system refrigerant pressures 

and temperatures enough time to return to a stabilized 

condition.

•  In Emergency Heat mode, all heating demand is 

satisfied  by  auxiliary  heat;  heat  pump  operation  is 

locked out. After a 6 hour “warm-up” period, the 

thermostat can then be switched to the “Heat” setting 

and normal heat pump operation may resume.

Thermostat Operation

The wall-mounted thermostat controls your heat pump. 

The thermostat is available in various configurations from 

different manufacturers. The information below is typical for 

most thermostats. Ask your dealer for specific information 

regarding the model of thermostat installed.

Fan Switch

In AUTO or INT (intermittent) mode, the blower operates 

only when the thermostat calls for heating or cooling. This 

mode is generally preferred when humidity control is a 

priority. 

The ON or CONT mode provides continuous indoor 

blower operation, regardless of whether the compressor or 

auxiliary heat are operating. This mode is required when 

constant air circulation or filtering is desired.

On models without a fan selection switch, the fan will cycle 

with the outdoor unit.

System Switch

Set the system switch for heating, cooling or auto 

operation. The auto mode allows the heat pump to 

automatically switch from heating mode to cooling mode to 

maintain predetermined comfort settings. Many heat pump 

thermostats are also equipped with an emergency heat 

mode which locks out heat pump operation and provides 

temporary heat supplied by the auxiliary heat.

Содержание 4HP14

Страница 1: ...alified personnel and do not supersede any national or local codes in any way The installation must comply with all provincial state and local codes as well as the National Electrical Code U S or Cana...

Страница 2: ...nstalled on a solid foundation This foundation should extend a minimum of 2 inches beyond the sides of the outdoor section To reduce the possibility of noise transmission the foundation slab should NO...

Страница 3: ...l or other barrier Table 2 Clearances 30 around Control Box 24 6 NOTE See Table 2 for specific minimum clearance guidelines Figure 2 DO LOCATE THE UNIT With proper clearances on sides and top of unit...

Страница 4: ...8 042 3 8 3 8 7 8 7 8 048 3 8 3 8 7 8 7 8 060 3 8 3 8 7 8 1 1 8 Field supplied 7 8 x 1 1 8 connector required on both ends of vapor tubing Table 3 Recommended Liquid Vapor Tube Diameters in Be extra c...

Страница 5: ...UNIT VAPOR LINE SERVICE VALVE VAPOR LIQUID 1 A B C D A Cylinder with clean R 410A positioned to deliver liquid refrigerant to the vapor service valve B Refrigerant gauge set low side to the liquid lin...

Страница 6: ...il Shown Sensing bulb insulation is required if mounted external to the coil casing sensing bulb installation for bulb positioning STUB END TEFLON RING LIQUID LINE ASSEMBLY WITH BRASS NUT DISTRIBUTOR...

Страница 7: ...ound Do not crimp end of the line Remove service cap and core from both the vapor and liquid line service ports 1 2 LIQUID LINE SERVICE VALVE SERVICE PORT CORE SERVICE PORT CAP SERVICE PORT CORE SERVI...

Страница 8: ...ES POINT FLAME AWAY FROM SERVICE VALVE PREPARATION FOR NEXT STEP 7 WRAP SERVICE VALVES To help protect service valve seals during brazing wrap water saturated cloths around service valve bodies and co...

Страница 9: ...of the manifold gauge set in order to pressurize the line set and the indoor unit E After a few minutes open one of the service valve ports and verify that the refrigerant added to the system earlier...

Страница 10: ...id refrigerant Open the manifold gauge valve 1 to 2 psig in order to release the vacuum in the line set and indoor unit G Perform the following Close manifold gauge valves Shut off HFC 410A cylinder R...

Страница 11: ...nch with a hex head extension to back the stem out counterclockwise as far as it will go Use a 3 16 hex head extension for liquid line service valves and a 5 16 extension for suction line service valv...

Страница 12: ...the low voltage field wiring 2 Ground unit at unit disconnect switch or to an earth ground To facilitate conduit a hole is in the bottom of the control box Connect conduit to the control box using a...

Страница 13: ...or varying lengths of line set refer to Table 4 for refrigerant charge adjustment A blank space is provided on the unit rating plate to list the actual field charge Table 4 Refrigerant Charge Adjustme...

Страница 14: ...for 90 seconds following the start up of the compressor during test mode High Pressure Switch HI PS When the high pressure switch trips the defrost board will cycle off the compressor and the strike c...

Страница 15: ...ition at power up the control will ignore the test pins When the jumper is placed across the TEST pins for 2 seconds the control will enter the defrost mode If the jumper is removed before an addition...

Страница 16: ...ent fins may affect unit operation SHARP OBJECT HAZARD Condenser coils have sharp edges Wear adequate body protection on body extremities e g gloves FAILURE TO FOLLOW THIS WARNING COULD RESULT IN BODI...

Страница 17: ...he defrost cycle In case of extended power outage If the outdoor temperature is below 50 F and power to your outdoor unit has been interrupted for one hour or longer observe the following when restori...

Страница 18: ...506318 03 Page 18 of 18 Issue 1946 Figure 8 14 15 SEER Wiring Diagram...

Отзывы: