Lennox 3PC036 Скачать руководство пользователя страница 21

21

Manual Control Button

Manual control 

button

Figure 29. Manual Control Button

Dry Mode Operation (Dehumidification)

Procedure

1. 

Using the provided wireless remote control, press the 

MODE

 button and select 

DRY

 mode.

2.   Press  the 

UP/ DOWN

 button to select the desired 

temperature. The temperature setting range is from 

62°F (17°C) to 86°F (30°C) in one degree increments.

NOTE: 

The blower is preset at a low speed and cannot be 

changed therefore it will get cold and most likely 

will surpass the temperature setting by 6-10

°

F (3-

5

°

C) depending on the room size or other various 

factors. Also the 

Follow Me

 

mode does not 

operate in this mode. 

NOTE: 

In addition, the indoor units do not have a humidistat 

installed therefore they are unable to determine 

humidity levels. This product is not recommend as 

a main source for dehumidification.

Sequence of Operation

When in dry mode operation the unit is actually in cooling 

mode with a low speed blower operation. Set remote temp 

to a lower room temp to begin the dry mode operation. 

The compressor will stop when the room temperature is 

4°F (2°C) lower than the temperature setting.  
However there is a temperature compensation for cooling 

mode that is two degrees Celsius. So the unit will stop 

when the temperature is 8°F (4°C) lower than the room 

temperature settings.

Содержание 3PC036

Страница 1: ...7784 01 Table of Contents General 1 Included Parts 2 Model Number Identification 3 Indoor Outdoor Unit Match Ups 4 Typical System Components 4 System Dimensions 5 Outdoor Units 5 Indoor Units 6 System...

Страница 2: ...er guide 1 ea Wireless control holder with 2 mounting screws 1 Mounting plate with mounting screws and anchors FROM EDGE TO HOLE CENTER 50mm FROM EDGE TO HOLE CENTER 100mm 150 100 100 100 50 50 50 2 2...

Страница 3: ...ominal Cooling Capacity 036 3 tons Refrigerant Type 4 HFC 410A Minor Design Sequence 1 1st Revision 3 P C 036 S 4 S 1 P Series Type 3 3 ton outdoor unit for 3PC 3WMC Wall Mount system OUTDOOR SINGLE Z...

Страница 4: ...Panel Outdoor Unit Power Cable 1 2 3 4 5 6 7 8 9 10 1 2 3 4 6 7 8 9 10 5 Humidity Boost IMPORTANT The refrigerant metering device for this system is located in the outdoor unit This makes it necessary...

Страница 5: ...SIDE VIEW 37 1 4 946 26 1 2 673 40 1 2 1029 GAS VALVE LIQUID VALVE 2 3 8 60 4 1 4 108 3 5 8 92 18 1 8 460 18 457 15 7 8 403 DRAIN HOLE Bottom of Unit 31 7 8 810 15 1 4 387 16 1 8 410 2 7 8 73 1 25 Fi...

Страница 6: ...O HOLE CENTER 70mm BUBBLE LEVEL 150 100 50 2 4 6 RECOMMAND mm inch 100 100 50 50 2 2 4 4 LIQUID GAS mm inch Indoor unit outline Right rear side refrigerant pipe inlet 2 1 2 64 diameter Left rear side...

Страница 7: ...th no obstructions on the other three sides Figure 5 Outdoor Unit Clearances Inches mm Indoor Unit FRONT VIEW Wall Vertical Clearance Clearance to Floor 72 inches 1829 mm Minimum 96 inches 2438 mm Rec...

Страница 8: ...local codes Allow sufficient space around unit for proper operation and maintenance Install unit a minimum of 3 feet 1m away from any antenna power cord line radio telephone security system or interc...

Страница 9: ...sed to these construction materials Installation of Indoor Unit on Wall Mounting Plate 1 A length of field provided flexible condensate piping should be connected to the drain prior to securing the un...

Страница 10: ...tall the unit as far as possible from the prop erty line When possible do not install the unit directly outside a window Glass has a very high level of sound trans mission Install unit level Ground Le...

Страница 11: ...et Figure 14 Outdoor Unit on Brackets above Snow Line Air Outlet Air Inlet 12 in 305 mm 79 in 2007 mm Figure 15 Outdoor Unit Air Flow Obstructed by Snow Figure 16 Avoid Defrost Water Ice Hazard Prevai...

Страница 12: ...low drainage to occur If the heat pump unit is installed on wall mounting bracket insert the provided drain connector into one of the 1 inch 25 mm drain holes and attached a field provided insulated d...

Страница 13: ...using Table 3 Refrigerant Piping and Indoor Unit Connection Sizes on page 14 2 Confirm that you are using the correct diameter piping 3 Determine the necessary piping length required for the applicat...

Страница 14: ...Refrigerant Piping and Indoor Unit Connection Sizes Size Btuh Liquid Line in Suction Line in 36000 3 8 5 8 A B CANT ON THE OUTSIDE OF THE FLARE MALE FLARE CONNECTION Figure 25 Making Connections Male...

Страница 15: ...tested and evacuated to remove any non condensables and moisture from the system Leak Test Use the following procedure to test for system leaks 1 Connect the manifold gauge set and dry nitrogen gas c...

Страница 16: ...e to reattach all electrical box covers after con nections are complete Indoor Unit Indoor unit is powered by the outdoor unit Communication Wiring Use one stranded 3 conduc tor wire to provide power...

Страница 17: ...17 T5 T5 NOTE Recommend to use two core shielded wire Figure 27 3PC036 Outdoor Unit Wiring Diagram...

Страница 18: ...ed 24 hours before unit start up to prevent compressor damage as a result of slugging 1 Inspect all factory and field installed wiring for loose connections 2 Verify that the manifold gauge set is con...

Страница 19: ...e detection PC 00 Error Inverter module IPM error PC 01 Error High or Low voltage protection PC 02 Error High temperature sensed at compressor top PC 03 Error Low or High pressure protection PC 04 Err...

Страница 20: ...he mode button to scroll through the following functions one at a time COOL Select lowest possible temperature HEAT Select highest possible temperature 4 Let each function run for 5 minutes and perfor...

Страница 21: ...e or other various factors Also the Follow Me mode does not operate in this mode NOTE In addition the indoor units do not have a humidistat installed therefore they are unable to determine humidity le...

Страница 22: ...ture Figure 30 Self Clean User Information Indoor Unit Display Remote Control Remote Control Holder Louver Front Panel Air Filter pull up Display window ECO intelligent eye Humidity Boost Figure 31 In...

Страница 23: ...ow out After cleaning the internal blower then keeps operating with hot air to blow dry the evaporator thus preventing the growth of mold and keeping the inside clean When this function is turned on t...

Страница 24: ...r operation use the remote control to activate the unit Unit must be turned off before manual operation To operate your unit manually 1 Locate the MANUAL CONTROL button on the right hand side panel of...

Отзывы: