507428-01
18
Basic Dew Point Control
adjustment mode will change
the humidification setpoint based on the outdoor
temperature and a user-defined dew point adjustment
setting.
Precision Dew Point Control
adjustment mode will
operate when these conditions are met:
humidification mode has been enabled, and
the unit is in HEAT mode, and
humidification demand exists (24V present at H).
HUMIDIFICATION SETTINGS — FEATURE
SCREEN
SYSTEM SETTINGS
current indoor humidity is 50%
humidifier
is ON
de-
humidifier
MEDIUM
40
%
set to
50
%
set to
ALL CHANGES MADE ON
THIS SCREEN ARE IN
STANTLY SAVED.
9:39 am Aug 15, 2012
?
Wi-Fi
OFF
MEDIUM
HIGH
humidifier
display
is ON
humidification
settings
dehumidification
settings
Figure 14. Humidification Controls
1.
From the
Main Screen
, touch the
right arrow
icon
to go the the
Features
screen.
2.
From the
Features
screen, select
system
settings.
3.
Touch the button of the humidification settings you
want to adjust; if it says humidifier OFF, one touch
will display a selection for ON.
4.
When you touch the
set-to
button, the arrows
appear, allowing you to change to the desired
humidity percentage setting.
DEHUMIDIFICATION SETTINGS — SYSTEM
DEVICES SCREEN
Pre-adjustment REQUIREMENTS
First
the device has been
installed
Second
, from the “Add or Remove
Non-communicating equipment?”, touch
next
.
Third
, in the “Adjust a setting...” screen, configure
the device as follows:
1.
In the “system devices” list, use the arrows to
highlight
System
. Touch
edit
.
2.
Use arrows to highlight
Min Dehumidification
Setpoint
; touch
edit
. Note the current value (e.g.
45).
3.
Use arrows to make changes; touch
(After saving,
check that the current value now shows the new
selection).
4.
Touch the
back
button to return to “Adjust a
setting...” screen.
DEHUMIDIFICATION SETTINGS — FEATURE
SCREEN
1.
From the
Main Screen
, touch the
right arrow
icon
to go the the
Features
screen.