![Lennox Hearth Products RAVELLE 30 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/lennox-hearth-products/ravelle-30/ravelle-30_installation-and-operation-manual_1878455005.webp)
5
PRE-INSTALLATION
Features
Installation Options
Residential
Vented vertical and horizontal
Manufactured (mobile) home
Natural gas (NG) or propane (LP)
Bedrooms
Optional wall-mounted or remote thermostat
Venting
This fireplace can be vented with Security™ Secure Vent™ pipe*. Coaxial
pipe diameters are 6-5/8” outer and 4” inner. The combustion air for this
fireplace is drawn from outside the house through the outer DV (direct
vent) pipe. Room air is not required for combustion.
When planning your installation, select the correct length of vent pipe
for your particular requirements. Determine the minimum clearance to
combustibles from the rear of the unit to the wall. It is also important to
note the thickness of the wall. Before cutting the vent hole through the
wall make sure that ALL vent and termination clearances (see
Pages 15
- 18)
will be met.
Electrical
The standard fan motor requires 120 Volts AC for operation. The fireplace
is not dependent on the fan or an outside electrical supply to operate.
Millivolt Valve
This fireplace is operated with a millivolt valve and therefore burns even
during a power outage.
Fuel
This fireplace comes from the factory equipped to burn natural gas at a
specified elevation. The fireplace can be converted to burn LP gas (liquid
propane) by changing the cassette (valve and pilot assembly) or installing a
conversion kit. Only Lennox Hearth Products conversion kits can be used to
convert from NG to LP or LP to NG. Contact your Lennox Hearth Products
dealer for details.
Specifications
Fireplace weight: 200 lbs
Pipe:Type - direct-vent
Recommended manufacturer*
Security Secure Vent*
Diameter - 6-5/8”x 4” for all installations
Packaging List
The Ravelle™ 30 gas fireplace comes with the following parts:
1 Fireplace Body with Burner Cassette
1 Log Set
1 Set of Refractory Brick Panels (3 pieces)
1 Bag of Ember Material
1 Installation and Operation Manual
Decorative Faces - One Required
Arch Inset
Classic Inset
Screen
Foundry™
Cast Pillar
Brick Liners - One Required
Standard Tan Brick
Red Brick
Note: See Pages 32 and 33 for ordering information.
* Other approved chimney brand is Simpson Dura-Vent DV-GS.
RATINGS
Ravelle 30 (RAVL30)
NATURAL GAS
LP GAS
Max/Min Input BTUh 0-,000 Feet (0-610 M)
u
30,000 / 0,000
8,500 / 0,000
Manifold Pressure (IN. WC)
3.5 / 1.7
11 / 5.4
Min. Inlet Pressure (IN. WC)
5
11
Maximum heat output BTUs/hour-steady state
4,600
3,370
P4 Efficiency
w
56.88%
67.04%
Orifice (DMS) 0-,000 Feet (0-610 M)
u
#37
#51
u
Unit factory equipped for 0-000 FT/0-610 M, In Canada 0-4500 FT/0-1370 M
v
The Steady State Efficiency numbers based on maximum vent configuration.
w
Tested to CSA P.4.1-0 “Testing Method for Measuring Annual Fireplace Efficiency.
Electrical Rating: 10 VAC, 60 HZ, Less Than Amps
Ductability (optional)
Whole Home Comfort
System