background image

Chimney

Elbow

Offset & 

Height

Two Lengths Between Elbows

8”

12”

18”

24”

36”

8” & 36”

12” & 36”

18” & 36”

24” & 36”

36” & 36”

GX

S2100+

7”

15º

A

3”

(76 mm)

4-1/4”

(108 mm)

5-3/4”

(146 mm)

7-1/4”

(184 mm)

10-1/4”

(260 mm)

12-1/4”

(311 mm)

13-1/4”

(337 mm)

14-3/4”

(375 mm)

16-1/4”

(413 mm)

19-1/2”

(495 mm)

B

20-3/4”

(527 mm)

24-1/4”

(616 mm)

29-1/2”

(749 mm)

34-3/4”

(883 mm)

45”

(1143 mm)

51-1/4”

(1302 mm)

54-3/4”

(1391 mm)

60”

(1524 mm)

65-1/4”

(1657 mm)

75-1/2”

(1918 mm)

30º

A

7-1/2”

(191 mm)

9-1/2”

(241 mm)

12-1/2”

(318 mm)

15-1/2”

(394 mm)

21-1/2”

(546 mm)

25”

(635 mm)

27”

(686 mm)

30”

(762 mm)

33”

(838 mm)

39”

(991 mm)

B

16-1/2”

(419 mm)

20-1/4”

(514 mm)

26-1/4”

(667 mm)

32”

(813 mm)

43-1/2”

(1105 mm)

50-1/2”

(1383 mm)

54-1/4”

(1378 mm)

60”

(1524 mm)

65-3/4”

(1670 mm)

77-1/2”

(1969 mm)

45º

Canada 

Only

A

10”

(254 mm)

12-3/4”

(324 mm)

17”

(432 mm)

21-1/4”

(540 mm)

29-3/4”

(755 mm)

34-11/32”
(872 mm)

37-5/32”

(949 mm)

41-13/32”

(1052 mm)

45-21/32”

(1160 mm)

54-1/8”

(1375 mm)

B

17-9/16”

(446 mm)

20-7/16”

(519 mm)

24-5/8”

(625 mm)

28-7/8”

(733mm)

37-3/8”

(949 mm)

42”

(1067 mm)

44-3/4”

(1137 mm)

49”

(1245 mm)

59-9/32”

(1353 mm)

61-3/4”

(1568 mm)

Chimney

  

Elbow

Offset & 

Height

One Length Between Elbows

Two Lengths Between Elbows

---

12” 18”

36”

48”

---

12” & 48”

18” & 48”

36” & 48”

48” & 48”

ACBI

7”

15º

A

----
----

5-1/2”

(140 mm)

7”

(178 mm)

11-1/2”

(292 mm)

14-3/4”

(375 mm)

----
----

17-1/2”

(445 mm)

19”

(483 mm)

23-5/8”

(600 mm)

26-3/4”

(679 mm)

B

----
----

32-1/4”

(819 mm)

38”

(965 mm)

55-1/2”

(1410 mm)

67”

(1702 mm)

----
----

77-1/8”

(1959 mm)

82-7/8”

(2105 mm)

100-1/4”

(2318 mm)

111-1/8”

(2823 mm)

30º

A

----
----

10-1/2”

(267 mm)

13-1/2”

(343 mm)

22-1/2”

(543 mm)

28-1/2”

(724 mm)

----
----

33-3/4”

(857 mm)

36-3/4”

(933 mm)

45-3/4”

(1162 mm)

51-3/4”

(1314 mm)

B

----
----

30-1/8”

(765 mm)

35-3/8”

(899 mm)

51”

(1295 mm)

61-3/8”

(1559 mm)

----
----

70-1/2”

(1791 mm)

75-5/8”

(1921 mm)

91-1/4”

(2318 mm)

101-5/8”

(2581 mm)

Note: With the ACBI chimney, a starting length of 6” high must be used on top of the fi replace before installing.

Figure 27

Horizontal Offset

Total Height

Offset Dimensions

A

B

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

16

Содержание MONTECITO ESTATE MONTEST

Страница 1: ...e la demande Num ro de la pi ce 850 038CF INSTALLATION AND OPERATING INSTRUCTIONS RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Listed to standards ULC S610 UL 127 Report No 304 7213 EPA Cert No 609...

Страница 2: ...e left partly opened smoke may be drawn into the room Use optional firescreen when doors are fully opened WARNING Usecarewhenselectingwindow treatments for windows located near the fireplace Avoid usi...

Страница 3: ...PARTS REQUIRED Fireplace model MONTEST 7 diameterchimney Model SecureTemp S 2100 Nova Temp HT6000 Secure TempGX U S only or ACBI manufactured by Security Chimneys International only including Chimney...

Страница 4: ...burnveryintenselyus ing this method and may damage the firebox Medium Combustion This is the recommended mode of operating the Montecito Estate and should be the one normally used since it will deposi...

Страница 5: ...e will be between 6 8 hours and at this combustion rate the level of BTU s is at its lowest Building a Fire A To start a fire place several crumpled up ballsofnewspaperinthefirebox Placesmall dry piec...

Страница 6: ...e chimney WARNING When cleaning the fireplace the ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible floor or on t...

Страница 7: ...1 400 F If the glass breaks or cracks it must be replaced with an identical ceramic glass Tempered glass or ordinary glass will not withstand the high temperatures of the Montecito Estate Replacement...

Страница 8: ...A Frame the fireplace using 2 x 3 or heavier lumber B WARNING Combustible materials cannot be used in the space directly above the fireplace except for the studs above the fa cade that support the fa...

Страница 9: ...8 1686 mm Notes Due to Lennox ongoing commitment to quality all specifications ratings and dimensions are subject to change without notice All framing dimensions calculated for 1 2 dry wall at the fi...

Страница 10: ...It is located in the bottom of the fireplace towards the back It uses 120V and must be connected to the main electrical circuit byaqualifiedelectrician Forconnection usethe electrical box supplied wit...

Страница 11: ...eat A furnace duct is only single wall and not double wall as is required for the Montecito Estate hot air exhaust 7 Use only Security Chimneys International grills and components as described in this...

Страница 12: ...above or below floor level Makea4 1 4 110mm holeintheoutsidewallofthehouseatthechosen location From outside place the outside air register in the hole open side down and fasten the register to the wal...

Страница 13: ...are located on lower floors in the house such as in a basement in combination with an outside chimney are especially prone to flow reversal 2 The fireplace model MONTEST may be installed only with Se...

Страница 14: ...rsal support AC10SU 4 Put the roof flashing in place and seal the joint between the roof and the flashing with roofing pitch see Figures 25 26 For sloping roofs place the flashing under the upper shin...

Страница 15: ...ns on Page 14 5 From below install a firestop See Figure 23a 6 A support XST or XSO must be used on the first 15 section 5 m 7 Continue with the regular installation ACBI Chimney 1 Install the first e...

Страница 16: ...mm 45 21 32 1160 mm 54 1 8 1375 mm B 17 9 16 446 mm 20 7 16 519 mm 24 5 8 625 mm 28 7 8 733mm 37 3 8 949 mm 42 1067 mm 44 3 4 1137 mm 49 1245 mm 59 9 32 1353 mm 61 3 4 1568 mm Chimney Elbow Offset Hei...

Страница 17: ...diation Shield Framing 2 x 3 Figure 29 Roof Support Note In cold areas it is recommended to protect the chimney in a insulated chase Straps Chimney ACBI ACBI Starter Section Straps Outside Wall OFFSET...

Страница 18: ...t of supported chimney NOTE For the ACBI chimney a support section ACBI7SL must be used every 30 feet 9m or an universal support every 20 feet 6m instead of the universal roof support ST CHIMNEY MAXIM...

Страница 19: ...will enter the masonry chimney 2 In the middle of the oval drill a hole in the masonry chimney at 30 3 Increase the size of the hole until a 30 TUBINOX liner elbow can be easily slipped through 4 Slid...

Страница 20: ...ECMC H4855 Outside Air Kit included with fireplace Outside Air Coupler To Connect Outside Air UZI To Fireplace UZIAD UZIAD Outside Air Ducting includes 4 insulated flex x 10 long UZI UZI Gravity Kit G...

Страница 21: ...ashing Adjustable 30 45 includes spacer collar ACBI7FBR H3277 Misc Firestop ACBI7BF H3268 Radiation Shield ACBI7RS H3269 Attic Radiation Shield ACBI7RSA H3270 Telescopic Attic Radiation Shield ACBI7RS...

Страница 22: ...PR SR2417 Right Side Refractory Bricks Front PR SR2419 Left Side Refractory Bricks Back PR SR2416 Left Side Refractory Bricks Front PR SR2418 Bottom Refractory Brick PR SR2422 Wooden Door Handle PR SR...

Страница 23: ...NOTES 23...

Страница 24: ...ction which were not manufactured or supplied by LHP or for the labor necessary to install repair or remove such materials parts or construction All replacement or repair components will be shipped F...