Lennox Hearth Products MONTECITO ESTATE MONTEST Скачать руководство пользователя страница 3

TABLE OF CONTENTS

Safety Rules ......................................Page  2 
Introduction ......................................Page  3
Parts Required  .................................Page  3
Optional Equipment ...........................Page  3
Operating The Montecito Estate  .........Page 3
Fuel ...................................................Page  3
Combustion Control  .........................Page  4
Refueling For Best Performance .......Page  5
Smoking – Causes And 
  Troubleshooting ..............................Page  5
Important Cautions ...........................Page  6
Maintaining Your  
  Montecito Estate  ............................Page  6
Creosote ............................................Page  6
Chimney Maintenance .......................Page  6
Dealing With A Chimney Fire .............Page  6
Finish Door Casing Care ....................Page  6
Refractory Replacement ....................Page  6
Door Installation ...............................Page  7
Door Adjustment ...............................Page  7
Glass Care - Replacement .................Page  7
Glass Care - Cleaning ........................Page  7
Gasket Replacement  ........................Page  7
Fireplace Installation  ........................Page  8
Locating The Montecito Estate  ...........Page 8
Hearth Extension Requirements  .......Page  8
Framing, Facing And Mantel ..............Page  8
Hot Air Ducting Installation  ..............Page  10
Gravity Kit .........................................Page  10
Outside Air Kit  ..................................Page  12
Chimney System ...............................Page  13
Chimney Installation Notes ...............Page  13
Chimney Installation Instructions ......Page  14
Offset Chimney Installation ...............Page  15
Angled Wall Radiation Shield ............Page  18
Chimney Support Installation ............Page  18
Chimney Chase And 
  Multiple Terminations .....................Page  18
Masonry Application Instructions .....Page  19
Installation Accessories ....................Page  20
Chimney Components Lists ..............Page  20
Replacement Parts ............................Page  23
Specifi cations ....................................Page  23
Clearances ........................................Page  23
Warranty ...........................................Page  24

CONGRATULATIONS!

In selecting this LENNOX wood-burning appliance you have chosen one of the fi nest 
fi replaces available.  The Montecito Estate™ is a clean burning EPA certifi ed fi replace 
that is designed to provide you dependable service as well as warmth and enjoyment 
for many years to come.

Please carefully read and follow all of the instructions found in this manual.  Please pay 
special attention to the safety instructions provided in this manual.  This information 
will be useful to you now and in years to come, so keep the manual handy and refer to 
it as needed.

THE FIREPLACE

INTRODUCTION

The Montecito Estate wood-burning fi replace 
is an energy effi cient, heat circulating, closed 
combustion fi replace.  You will receive a lifetime 
of comfort and enjoyment from your fi replace 
provided it is installed, maintained and oper-
ated properly.

• 

Please read these instructions and retain 
this manual for future reference.

• 

Before beginning the fi replace installation, 
consult the local authorities to obtain your 
building permit and check your local building 
codes.  Install the fi replace only as described 
in these instructions and using only Lennox 
Hearth Products components.

• 

The Montecito Estate is not intended for use 
with a gas log set. Do not  use a fi replace 
insert or any other product with this fi replace 
unless it is specifi ed by Lennox for use 
with this appliance.  Failure to follow these 
instructions will void the certifi cation and the 
warranty of the fi replace and may result in 
an unsafe installation.

•  These appliances are designed to provide 

supplemental heat to the immediate area only. 
Therefore, it is advisable to have an alternate 
heat source when installed in a dwelling. 

•  These appliances are not approved for 

Manufactured Home installations.

PARTS REQUIRED

Fireplace model: MONTEST

  7” diameter chimney - 

Model  Secure Temp 

S-2100+, Nova Temp , Secure 
Temp

 

GX (U.S. only) or  ACBI manufactured 

by Security Chimneys International only, 
including:

- Chimney lengths
- Elbows (where necessary)
- Associated components as per these 

installation instructions

 ..

Decorative Doors 

- Required 

....

(Order Separately - See

 Page 20

)

  Front Facade kit - Required

...

(Order Separately - See

 Page 20

)

 UZY5 Blower

 (included in the fi replace).

  VRUW Blower Speed Control 

(included)

  Outside air kit (Included w/Fireplace)

OPTIONAL EQUIPMENT

  - AC Chimney Adaptor 
     (required if using AC Chimney) 
  - AC Chimney Outside Air Kit
  -  Gravity Venting System
 - 

Rigid 

Firescreen

OPTIONAL EQUIPMENT

Additional Equipment (optional)

  -  Gravity Venting System

 - TUBINOX chimney (or PROJET SS), 7” 

diameter with adaptor for installation in a 
masonry chimney.

OPERATING THE MONTECITO ESTATE

 

Fuel - USE SOLID NATURAL WOOD FUEL 
ONLY. 

The Montecito Estate is designed to 

work best when fueled with dry seasoned 
natural wood only.  Hardwoods are preferred 
to softwoods since the energy content of 
wood is relative to its density.  Hardwoods will 
result in a longer burning fi re and less frequent 
refueling.  A moisture content of 15% to 20% 
(seasoned) is recommended.  Wood that has 
been cut and split and let to dry under a cover 
for a period of one year will usually meet that 
criteria.   Excessively wet wood will be diffi cult 
to burn and will result in lower effi ciency, in-
creased creosoting and deposits on the glass 
and in the chimney.  Excessively dry wood will 
burn well but will also have higher emissions 
and shorter burning time.

Do not burn scrap or garbage, treated wood or 
wood such as driftwood from the ocean which 
has been exposed to salt or other chemicals.  
Salt or chemicals can corrode the fi rebox and 
chimney.  Do not burn large amounts of paper, 
cardboard, Christmas tree branches or build-
ing construction materials.  Intense fi ring with 
these materials may overheat the fi replace, 
causing damage to the unit, a fi re or even 
possibly igniting a chimney fi re if the chimney 
is creosoted.

First Fires
Before using the fi replace make sure to re-
move the plastic wrapping and EPA label on 
the door. Remove any glue residue left by the 
label using mild soap.

Make sure the doors are properly adjusted, 
thus avoiding color change to fi nish due to 
overheating.

The fi rst fi ve or six fi res should be small fi res 
of short duration (about 30 to 60 minutes).  
This will help cure the refractory bricks. The 
fi rst fi res may produce slight smoking due 
to curing of the paint and steel and the burn-
ing of any dust accumulated on the fi replace 
which will burn off at this time.  It may set off 
a smoke alarm located in the same room.  For 
this reason the room should be well ventilated 
for the fi rst few fi res.

HEAT OUTPUT

The Montecito Estate is the largest member of 
the “Dave Lennox Signature Collection” of high 
effi ciency fi replaces. The heat generated from its 
fi re is more effi ciently captured and distributed. 
In spite of the large amount of heat that the 
Montecito Estate can deliver, it should not replace 
the main source of heat in your home.  This 
fi replace will bring extra warmth and ambiance 
to your home by distributing its heat as describe 
further in the manual. 

3

Содержание MONTECITO ESTATE MONTEST

Страница 1: ...e la demande Num ro de la pi ce 850 038CF INSTALLATION AND OPERATING INSTRUCTIONS RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Listed to standards ULC S610 UL 127 Report No 304 7213 EPA Cert No 609...

Страница 2: ...e left partly opened smoke may be drawn into the room Use optional firescreen when doors are fully opened WARNING Usecarewhenselectingwindow treatments for windows located near the fireplace Avoid usi...

Страница 3: ...PARTS REQUIRED Fireplace model MONTEST 7 diameterchimney Model SecureTemp S 2100 Nova Temp HT6000 Secure TempGX U S only or ACBI manufactured by Security Chimneys International only including Chimney...

Страница 4: ...burnveryintenselyus ing this method and may damage the firebox Medium Combustion This is the recommended mode of operating the Montecito Estate and should be the one normally used since it will deposi...

Страница 5: ...e will be between 6 8 hours and at this combustion rate the level of BTU s is at its lowest Building a Fire A To start a fire place several crumpled up ballsofnewspaperinthefirebox Placesmall dry piec...

Страница 6: ...e chimney WARNING When cleaning the fireplace the ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible floor or on t...

Страница 7: ...1 400 F If the glass breaks or cracks it must be replaced with an identical ceramic glass Tempered glass or ordinary glass will not withstand the high temperatures of the Montecito Estate Replacement...

Страница 8: ...A Frame the fireplace using 2 x 3 or heavier lumber B WARNING Combustible materials cannot be used in the space directly above the fireplace except for the studs above the fa cade that support the fa...

Страница 9: ...8 1686 mm Notes Due to Lennox ongoing commitment to quality all specifications ratings and dimensions are subject to change without notice All framing dimensions calculated for 1 2 dry wall at the fi...

Страница 10: ...It is located in the bottom of the fireplace towards the back It uses 120V and must be connected to the main electrical circuit byaqualifiedelectrician Forconnection usethe electrical box supplied wit...

Страница 11: ...eat A furnace duct is only single wall and not double wall as is required for the Montecito Estate hot air exhaust 7 Use only Security Chimneys International grills and components as described in this...

Страница 12: ...above or below floor level Makea4 1 4 110mm holeintheoutsidewallofthehouseatthechosen location From outside place the outside air register in the hole open side down and fasten the register to the wal...

Страница 13: ...are located on lower floors in the house such as in a basement in combination with an outside chimney are especially prone to flow reversal 2 The fireplace model MONTEST may be installed only with Se...

Страница 14: ...rsal support AC10SU 4 Put the roof flashing in place and seal the joint between the roof and the flashing with roofing pitch see Figures 25 26 For sloping roofs place the flashing under the upper shin...

Страница 15: ...ns on Page 14 5 From below install a firestop See Figure 23a 6 A support XST or XSO must be used on the first 15 section 5 m 7 Continue with the regular installation ACBI Chimney 1 Install the first e...

Страница 16: ...mm 45 21 32 1160 mm 54 1 8 1375 mm B 17 9 16 446 mm 20 7 16 519 mm 24 5 8 625 mm 28 7 8 733mm 37 3 8 949 mm 42 1067 mm 44 3 4 1137 mm 49 1245 mm 59 9 32 1353 mm 61 3 4 1568 mm Chimney Elbow Offset Hei...

Страница 17: ...diation Shield Framing 2 x 3 Figure 29 Roof Support Note In cold areas it is recommended to protect the chimney in a insulated chase Straps Chimney ACBI ACBI Starter Section Straps Outside Wall OFFSET...

Страница 18: ...t of supported chimney NOTE For the ACBI chimney a support section ACBI7SL must be used every 30 feet 9m or an universal support every 20 feet 6m instead of the universal roof support ST CHIMNEY MAXIM...

Страница 19: ...will enter the masonry chimney 2 In the middle of the oval drill a hole in the masonry chimney at 30 3 Increase the size of the hole until a 30 TUBINOX liner elbow can be easily slipped through 4 Slid...

Страница 20: ...ECMC H4855 Outside Air Kit included with fireplace Outside Air Coupler To Connect Outside Air UZI To Fireplace UZIAD UZIAD Outside Air Ducting includes 4 insulated flex x 10 long UZI UZI Gravity Kit G...

Страница 21: ...ashing Adjustable 30 45 includes spacer collar ACBI7FBR H3277 Misc Firestop ACBI7BF H3268 Radiation Shield ACBI7RS H3269 Attic Radiation Shield ACBI7RSA H3270 Telescopic Attic Radiation Shield ACBI7RS...

Страница 22: ...PR SR2417 Right Side Refractory Bricks Front PR SR2419 Left Side Refractory Bricks Back PR SR2416 Left Side Refractory Bricks Front PR SR2418 Bottom Refractory Brick PR SR2422 Wooden Door Handle PR SR...

Страница 23: ...NOTES 23...

Страница 24: ...ction which were not manufactured or supplied by LHP or for the labor necessary to install repair or remove such materials parts or construction All replacement or repair components will be shipped F...