Lennox Hearth Products MONTECITO ESTATE MONTEST Скачать руководство пользователя страница 7

DOOR INSTALLATION

The doors must be put in place only when the installation of the Montecito 
Estate™ is completed.  All you have to do is fi t the male part of the hinge, 
already on the door, to the female part, which is on the fi replace. To remove 
the doors, simply pull them up from the hinges. The door adjustment 
has been set at the factory.  If the fi t is still not perfect, you can adjust 
the door using the hinge screws (See 

Figure 7-1

)

Figure 6 - 

Door Installation

DOOR ADJUSTMENT 

The doors may need to be adjusted to be completely airtight. The gaskets’ 
air-tightness can be adjusted using the adjustment screw located on the 
right side of the fi replace facade (An Allen key #1/8 – not supplied - will 
be necessary for this adjustment) (see 

Figure 7-2

).

Checking Door Seal

A one-inch strip of paper may be used to perform a test of the integrity 
of the door seal. Close the door on the paper in at least eight points.  It 
is normal to feel only a slight amount of friction. The door gasket does 
not need to be “tight” in all areas, since a small amount of leakage is not 
hazardous or detrimental to the performance of your fi replace.

  WARNINGS

 

Use only a Lennox Hearth Products glass doors, 
specifi cally designed for the Montecito Estate 
fi replace.

 

The fi replace cannot be operated without a door.  
Consult your dealer to select the correct door 
model.

 

Important! To assure proper alignment of glass 
doors:  Install this fi replace in a square and 
plumb condition, using shims as necessary at 
sides and/or bottom.

2

Figure 7

GLASS CARE

Glass Replacement

The glass used for the Montecito Estate is a high temperature ceramic 
glass (1,400° F).  If the glass breaks or cracks, it must be replaced with 
an identical ceramic glass.  Tempered glass or ordinary glass will not 
withstand the high temperatures of the Montecito Estate .  Replacement 
glass should be purchased from a Security Chimneys International dealer 
(see 

“Replacement Parts”

 on 

Page 22

)

Do not operate the unit with cracked or broken glass.

Glass Cleaning

The Montecito Estate is designed to keep the glass clean under normal 
operating conditions. If the Montecito Estate is operated continuously 
with the combustion air controls closed, the glass will tend to get dirty 
unless the fuel, fi rebox and glass are maintained at hot temperatures (see 
section 

Refueling For Best Performance)

.  To clean the glass, there are a 

number of specially designed cleaners to remove creosote.  Your authorized 
Lennox Dealer can recommend a suitable cleaner.  Regular household 
glass cleaners will not clean creosote.  Do not use abrasives such as steel 
pads, steel wool or oven cleaner as they will scratch the glass.

Gasket Replacement

Remove the doors from the unit (see section 

Door Installation)

 and lay 

them on a clean nonabrasive surface. To replace the gasket, fi rst remove 
all of the old gasket and gasket cement.  Make sure that the surface is 
totally clean before applying new cement (a high temperature silicone 
caulking rated at 500° F (260° C), is suitable) or adhesion problems may 
result.  Apply gasket cement to the gasket channel and install the new 
gasket.  This replacement part is available from your Lennox Dealer in 
the following dimensions:

Gasket

Part #

Length

Qty

Dimensions

Around the glass

PR-SR-1685C

61-3/4”

2

1” width 

x 3/16” thick

On the door frame

PR-SR-1825I

48-3/8”

2

3/4” diameter

Between the 
doors

PR-SR-1823J

17-5/8”

2

5/8” diameter

Table 1

1

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

7

Содержание MONTECITO ESTATE MONTEST

Страница 1: ...e la demande Num ro de la pi ce 850 038CF INSTALLATION AND OPERATING INSTRUCTIONS RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Listed to standards ULC S610 UL 127 Report No 304 7213 EPA Cert No 609...

Страница 2: ...e left partly opened smoke may be drawn into the room Use optional firescreen when doors are fully opened WARNING Usecarewhenselectingwindow treatments for windows located near the fireplace Avoid usi...

Страница 3: ...PARTS REQUIRED Fireplace model MONTEST 7 diameterchimney Model SecureTemp S 2100 Nova Temp HT6000 Secure TempGX U S only or ACBI manufactured by Security Chimneys International only including Chimney...

Страница 4: ...burnveryintenselyus ing this method and may damage the firebox Medium Combustion This is the recommended mode of operating the Montecito Estate and should be the one normally used since it will deposi...

Страница 5: ...e will be between 6 8 hours and at this combustion rate the level of BTU s is at its lowest Building a Fire A To start a fire place several crumpled up ballsofnewspaperinthefirebox Placesmall dry piec...

Страница 6: ...e chimney WARNING When cleaning the fireplace the ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible floor or on t...

Страница 7: ...1 400 F If the glass breaks or cracks it must be replaced with an identical ceramic glass Tempered glass or ordinary glass will not withstand the high temperatures of the Montecito Estate Replacement...

Страница 8: ...A Frame the fireplace using 2 x 3 or heavier lumber B WARNING Combustible materials cannot be used in the space directly above the fireplace except for the studs above the fa cade that support the fa...

Страница 9: ...8 1686 mm Notes Due to Lennox ongoing commitment to quality all specifications ratings and dimensions are subject to change without notice All framing dimensions calculated for 1 2 dry wall at the fi...

Страница 10: ...It is located in the bottom of the fireplace towards the back It uses 120V and must be connected to the main electrical circuit byaqualifiedelectrician Forconnection usethe electrical box supplied wit...

Страница 11: ...eat A furnace duct is only single wall and not double wall as is required for the Montecito Estate hot air exhaust 7 Use only Security Chimneys International grills and components as described in this...

Страница 12: ...above or below floor level Makea4 1 4 110mm holeintheoutsidewallofthehouseatthechosen location From outside place the outside air register in the hole open side down and fasten the register to the wal...

Страница 13: ...are located on lower floors in the house such as in a basement in combination with an outside chimney are especially prone to flow reversal 2 The fireplace model MONTEST may be installed only with Se...

Страница 14: ...rsal support AC10SU 4 Put the roof flashing in place and seal the joint between the roof and the flashing with roofing pitch see Figures 25 26 For sloping roofs place the flashing under the upper shin...

Страница 15: ...ns on Page 14 5 From below install a firestop See Figure 23a 6 A support XST or XSO must be used on the first 15 section 5 m 7 Continue with the regular installation ACBI Chimney 1 Install the first e...

Страница 16: ...mm 45 21 32 1160 mm 54 1 8 1375 mm B 17 9 16 446 mm 20 7 16 519 mm 24 5 8 625 mm 28 7 8 733mm 37 3 8 949 mm 42 1067 mm 44 3 4 1137 mm 49 1245 mm 59 9 32 1353 mm 61 3 4 1568 mm Chimney Elbow Offset Hei...

Страница 17: ...diation Shield Framing 2 x 3 Figure 29 Roof Support Note In cold areas it is recommended to protect the chimney in a insulated chase Straps Chimney ACBI ACBI Starter Section Straps Outside Wall OFFSET...

Страница 18: ...t of supported chimney NOTE For the ACBI chimney a support section ACBI7SL must be used every 30 feet 9m or an universal support every 20 feet 6m instead of the universal roof support ST CHIMNEY MAXIM...

Страница 19: ...will enter the masonry chimney 2 In the middle of the oval drill a hole in the masonry chimney at 30 3 Increase the size of the hole until a 30 TUBINOX liner elbow can be easily slipped through 4 Slid...

Страница 20: ...ECMC H4855 Outside Air Kit included with fireplace Outside Air Coupler To Connect Outside Air UZI To Fireplace UZIAD UZIAD Outside Air Ducting includes 4 insulated flex x 10 long UZI UZI Gravity Kit G...

Страница 21: ...ashing Adjustable 30 45 includes spacer collar ACBI7FBR H3277 Misc Firestop ACBI7BF H3268 Radiation Shield ACBI7RS H3269 Attic Radiation Shield ACBI7RSA H3270 Telescopic Attic Radiation Shield ACBI7RS...

Страница 22: ...PR SR2417 Right Side Refractory Bricks Front PR SR2419 Left Side Refractory Bricks Back PR SR2416 Left Side Refractory Bricks Front PR SR2418 Bottom Refractory Brick PR SR2422 Wooden Door Handle PR SR...

Страница 23: ...NOTES 23...

Страница 24: ...ction which were not manufactured or supplied by LHP or for the labor necessary to install repair or remove such materials parts or construction All replacement or repair components will be shipped F...

Отзывы: