The unit will burn best with 2-3 pieces of cord 
wood spaced 1 to 2 inches apart and allowing 
air to get under the fuel.  Criss-crossing or ar-
ranging the fuel so that air can get underneath 
will help the fi re to get started easily. The unit 
should be operated with the air control fully 
open long enough to get the cord wood well 
ignited.

REFUELING FOR BEST PERFORMANCE

To reload the Montecito Estate at the end of a 
combustion cycle, when no fl ame is visible and 
there are only ashes left:

A) Completely open the air control level and 

the T.D.A.B. (Time Delay Air Boost) level.  
See 

Figure 1

.

B) Open the doors about 1” and wait 5 seconds 

until the air fl ow has stabilized.  Then open 
the doors completely, put the logs in and 
close the doors. 

C) Set the air control to the desired burn level. 

The T.D.A.B will close by itself progres-
sively.

To reload the Montecito Estate when the fi replace 
is still hot with a few visible fl ames:

A) Open the air control completely. The T.D.A.B 

can be set to a lower setting in order to 
facilitate lighting.

B) Open the doors about 1” and wait 5 seconds 

until the air fl ow has stabilized.  Then open 
the doors completely, put the logs in and 
close the doors.

C) Set the air control to the desired burn 

level.

Notes: 

•  For spectacular fi re and optimization of  the 

fi replace effi ciency, we recommend that the 
wood load be placed as far back as pos-
sible.

•  It may be necessary to turn off any blower(s) 

in operation during the refueling process in 
order to minimise smoking in the room.  It 
is recommended to wait 15 to 30 minutes 
before turning the blower(s) back on to 
ensure successful rekindling.

SMOKING – 
CAUSES AND TROUBLESHOOTING

To reduce the likelihood of smoke coming 
into the room when opening the door, set the 
combustion air controls to the left (“Acceler-
ated Combustion”) before opening the door.  
Your fi replace has been designed and tested 
to provide smoke free operation.

Slow Combustion

When the air combustion control is completely 
closed, the fi replace is in a slow combustion 
phase. If the hearth is hot enough, slow com-
bustion will not extinguish the fi re, but there 
will be a noticeable change in the fl ame pattern. 
The fl ames will be slow and may appear dirty 
if the wood is too wet (moisture content of 
20% and more).

Do not allow the wood to burn without fl ame, 
since this will produce excessive creosote in 
the unit. Creosote may accumulate on the glass 
door. This method of burning should be used 
only after operating the Montecito Estate™ with 
the air control opened to produce a hot fi re for 
about an hour or at medium pace for at least 
three (3) hours. Slow combustion can be used 
at night in order to reduce the heat output and 
to prolong the burn. The loading time will be 
between 6-8 hours and at this combustion rate, 
the level of BTU’s is at its lowest.

Building a Fire

A) To start a fi re, place several crumpled up 

balls of newspaper in the fi rebox.  Place small 
dry pieces of kindling on top of the paper, 
criss-crossing the kindling so that there are 
air spaces in between. The kindling should 
be placed at the center of the fi rebox so as 
to allow for suffi cient air circulation. 

B) Adjust the primary air control and start the 

time delayed air-boost system by pushing 
the register towards the right. Light the 
newspaper. Leave the doors partially opened 
to facilitate the start-up.

C) Once kindling fi re is well established, cord 

wood can be added. You may set the primary 
air control to the desire level (see 

Primary 

Air Combustion Control

 and 

Air Boost Con-

trols

 section for proper operation of the air 

controls).

D) Set the primary control to the desired burn 

level. The fi replace will automatically go to 
that level after the fi re is fully established 
and the air boost is closed.

As the fi re burns, air goes up the chimney.  This 
air must be replaced through the outside air duct.  
When operating the Montecito Estate, open a 
nearby window temporarily to check if there is 
adequate air supply replacement.  Occasionally, 
there may be a small amount of smoking upon 
lighting the fi re, until the chimney heats up but 
this should not last.  If the fi replace continues 
to smoke it is probably for one of the follow-
ing reasons:

A. The doors are partially opened

  When you open the doors, open them com-

pletely.

B. Negative pressure in the house
C. Fans operating (e.g.: range hood)

  These fans draw air out of the house and 

may actually cause a negative pressure in the 
house.  Turn off all fans and open a nearby 
window to determine if this is the cause of 
the problem.

D. Wet wood 

 

Wet or tarred wood will smoulder and smoke 
instead of burn properly.

E. Dirty or blocked chimney

 

Check to make sure the chimney is clear and 
clean.

F.  Chimney not long enough

  The minimum chimney height is 12 feet not 

including the fi replace height.  The chimney 
must extend at least three (3) feet (915 mm) 
above its point of contact with the roof and 
at least two (2) feet (610 mm) higher than 
any roof or wall within ten (10) feet (3 m) 
of it.  When installed with offsets, the mini-
mum chimney height is 15 feet.  Additional 
height will increase draft and will decrease 
the tendency to smoke.

G. Poor chimney draft

  With no fi re, there should be suffi cient draft 

to exhaust cigarette smoke introduced under 
the baffl e.  Chimneys installed against an 
outside wall without protection may gener-
ate back draft problems which will cause 
start-up problems.  To prevent this, open 
a nearby window; roll up a piece of paper, 
light it and hold it in the upper part of the 
fi rebox to warm up the chimney.  Wait until 
the draft is suffi cient, then start the fi re.

Figure 4 - 

Slow Combustion

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

5

Содержание MONTECITO ESTATE MONTEST

Страница 1: ...e la demande Num ro de la pi ce 850 038CF INSTALLATION AND OPERATING INSTRUCTIONS RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Listed to standards ULC S610 UL 127 Report No 304 7213 EPA Cert No 609...

Страница 2: ...e left partly opened smoke may be drawn into the room Use optional firescreen when doors are fully opened WARNING Usecarewhenselectingwindow treatments for windows located near the fireplace Avoid usi...

Страница 3: ...PARTS REQUIRED Fireplace model MONTEST 7 diameterchimney Model SecureTemp S 2100 Nova Temp HT6000 Secure TempGX U S only or ACBI manufactured by Security Chimneys International only including Chimney...

Страница 4: ...burnveryintenselyus ing this method and may damage the firebox Medium Combustion This is the recommended mode of operating the Montecito Estate and should be the one normally used since it will deposi...

Страница 5: ...e will be between 6 8 hours and at this combustion rate the level of BTU s is at its lowest Building a Fire A To start a fire place several crumpled up ballsofnewspaperinthefirebox Placesmall dry piec...

Страница 6: ...e chimney WARNING When cleaning the fireplace the ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible floor or on t...

Страница 7: ...1 400 F If the glass breaks or cracks it must be replaced with an identical ceramic glass Tempered glass or ordinary glass will not withstand the high temperatures of the Montecito Estate Replacement...

Страница 8: ...A Frame the fireplace using 2 x 3 or heavier lumber B WARNING Combustible materials cannot be used in the space directly above the fireplace except for the studs above the fa cade that support the fa...

Страница 9: ...8 1686 mm Notes Due to Lennox ongoing commitment to quality all specifications ratings and dimensions are subject to change without notice All framing dimensions calculated for 1 2 dry wall at the fi...

Страница 10: ...It is located in the bottom of the fireplace towards the back It uses 120V and must be connected to the main electrical circuit byaqualifiedelectrician Forconnection usethe electrical box supplied wit...

Страница 11: ...eat A furnace duct is only single wall and not double wall as is required for the Montecito Estate hot air exhaust 7 Use only Security Chimneys International grills and components as described in this...

Страница 12: ...above or below floor level Makea4 1 4 110mm holeintheoutsidewallofthehouseatthechosen location From outside place the outside air register in the hole open side down and fasten the register to the wal...

Страница 13: ...are located on lower floors in the house such as in a basement in combination with an outside chimney are especially prone to flow reversal 2 The fireplace model MONTEST may be installed only with Se...

Страница 14: ...rsal support AC10SU 4 Put the roof flashing in place and seal the joint between the roof and the flashing with roofing pitch see Figures 25 26 For sloping roofs place the flashing under the upper shin...

Страница 15: ...ns on Page 14 5 From below install a firestop See Figure 23a 6 A support XST or XSO must be used on the first 15 section 5 m 7 Continue with the regular installation ACBI Chimney 1 Install the first e...

Страница 16: ...mm 45 21 32 1160 mm 54 1 8 1375 mm B 17 9 16 446 mm 20 7 16 519 mm 24 5 8 625 mm 28 7 8 733mm 37 3 8 949 mm 42 1067 mm 44 3 4 1137 mm 49 1245 mm 59 9 32 1353 mm 61 3 4 1568 mm Chimney Elbow Offset Hei...

Страница 17: ...diation Shield Framing 2 x 3 Figure 29 Roof Support Note In cold areas it is recommended to protect the chimney in a insulated chase Straps Chimney ACBI ACBI Starter Section Straps Outside Wall OFFSET...

Страница 18: ...t of supported chimney NOTE For the ACBI chimney a support section ACBI7SL must be used every 30 feet 9m or an universal support every 20 feet 6m instead of the universal roof support ST CHIMNEY MAXIM...

Страница 19: ...will enter the masonry chimney 2 In the middle of the oval drill a hole in the masonry chimney at 30 3 Increase the size of the hole until a 30 TUBINOX liner elbow can be easily slipped through 4 Slid...

Страница 20: ...ECMC H4855 Outside Air Kit included with fireplace Outside Air Coupler To Connect Outside Air UZI To Fireplace UZIAD UZIAD Outside Air Ducting includes 4 insulated flex x 10 long UZI UZI Gravity Kit G...

Страница 21: ...ashing Adjustable 30 45 includes spacer collar ACBI7FBR H3277 Misc Firestop ACBI7BF H3268 Radiation Shield ACBI7RS H3269 Attic Radiation Shield ACBI7RSA H3270 Telescopic Attic Radiation Shield ACBI7RS...

Страница 22: ...PR SR2417 Right Side Refractory Bricks Front PR SR2419 Left Side Refractory Bricks Back PR SR2416 Left Side Refractory Bricks Front PR SR2418 Bottom Refractory Brick PR SR2422 Wooden Door Handle PR SR...

Страница 23: ...NOTES 23...

Страница 24: ...ction which were not manufactured or supplied by LHP or for the labor necessary to install repair or remove such materials parts or construction All replacement or repair components will be shipped F...

Отзывы: