Lennox Hearth Products EBVPFNE-B Скачать руководство пользователя страница 7

7

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

These appliances comply with National 

Safety Standards and are tested and listed 

by OMNI-Test Laboratories, Inc. (Report No. 

116-F-07A-5) to ANSI Z21.50 (in Canada, 

CSA-2.22), and CAN/CGA-2.17-M91 in both 

USA and Canada, as vented gas fireplaces.

The Installation must conform to local codes 

or, in the absence of local codes, with the 

National Fuel Gas Code, ANSI Z223.1/NFPA 

54-latest edition, or the Natural Gas and Propane 

Installation Code, CAN/CGA B149.1-latest edi-

tion.  The appliance, when installed, must be 

electrically grounded in accordance with local 

codes or, in the absence of local codes, the 

latest edition of the National Electrical Code, 

ANSI/NFPA 70, or the Canadian Electrical Code, 

CSA C22.1 - latest editions.

BTU Input

Millivolt Models - 

The millivolt appliances are 

manually controlled and feature a spark igniter 

(piezo) that allows the appliance's pilot gas to 

be lit without the use of matches or batteries.  

This system provides continued service in the 

event of a power outage.

Millivolt models come standard with a manu-

ally-modulated gas valve; flame appearance and 

heat output can be controlled at the gas valve. 

The BTU Input for these appliances is shown 

in 

Table 1.

Electronic Models - 

Electronic models have a 

fixed rate gas valve.  Input of electronic models 

is shown in 

Table 1

.

In Canada - CAN/CGA-2.17-M91 (R2009)(high 

altitude): THE CONVERSION SHALL BE CAR-

RIED OUT BY A MANUFACTURER’S AUTHO-

RIZED REPRESENTATIVE, IN ACCORDANCE 

WITH THE REQUIREMENTS OF THE MANU-

FACTURER, PROVINCIAL OR TERRITORIAL 

AUTHORITIES HAVING JURISDICTION AND 

IN ACCORDANCE WITH THE REQUIREMENTS 

OF THE CAN/CGA-B149.1 OR CAN/CGA-B149.2 

INSTALLATION CODES.

Burn-in Period

During the first few fires of this appliance there 

will be some odor due to the curing of the 

paint and burning off of lubricants used in the 

manufacturing process.  Depending on your 

use, the burn-in period may take a few hours 

or a few days.  

KEEP YOUR HOUSE WELL VENTILATED 

DURING THE CURING PROCESS.  THE ODOR 

AND HAZE EMITTED DURING THE CURING 

PROCESS CAN BE QUITE NOTICEABLE AND 

MAY SET OFF A SMOKE DETECTOR.

A white film may develop on the glass front 

during the first few fires as part of the curing 

process.  The glass should be kept clean during 

the first two weeks of use to prevent the film from 

baking on (making it very difficult to remove).  

See Cleaning Glass on 

Page 11

.

Test gauge connections are provided on the 

front of the millivolt and electronic gas control 

valve (identified IN for the inlet and OUT for the 

manifold side).  The control valves have a 3/8" 

(10mm) NPT thread inlet and outlet side of the 

valve (refer to 

Figures 2 and 3

).

Propane tanks are at pressures that will cause 

damage to valve components.  Verify that the 

tanks have step down regulators to reduce the 

pressure to safe levels.

Orifice Sizes -  Sea Level to High Altitude

(All Models)

These appliances are tested and approved for 

installation at elevations of 0-4500 feet (0-1372 

meters) above sea level using the standard burner 

orifice sizes (marked with an "*" in 

Table 4

).  For 

elevations above 4500 feet, contact your gas 

supplier or qualified service technician. 

Manifold Gas Supply Pressure

(all models)

Fuel #

Low

High

Natural 

Gas

(Lo) 2.2" WC

(0.55 kPa)

(Hi) 3.5" WC

(0.87 kPa)

Propane (Lo) 6.3" WC

(1.57 kPa)

(Hi) 10.0" WC

(2.49 kPa)

Table 3

The appliance and its appliance main gas 

valve must be disconnected from the gas 

supply piping system during any pressure 

testing of that system at test pressures 

in 

excess of

 1/2 psi (3.5 kPa).

The appliance must be isolated from the gas 

supply piping system by closing its equipment 

shutoff valve during any pressure testing of 

the gas supply piping system at test pres-

sures

 equal to or less than

 1/2 psi (3.5 kPa).

Inlet Gas Supply Pressure 

(all models)

Fuel #

Minimum

Maximum

Natural Gas

4.5" WC

(1.12 kPa)

10.5" WC

(2.62 kPa)

Propane

11.0" WC

(2.74 kPa)

13.0" WC

(3.24 kPa)

Table 2

Gas Pressure - All Models

Tables 2 and 3

 

show the appliances' inlet and 

manifold gas pressure requirements:

Deration -

 At higher elevations, the amount 

of BTU fuel value delivered must be reduced 

by either using gas that has been derated by 

the gas company or by changing the burner 

orifice to a smaller size as regulated by the 

local authorities having jurisdiction and by the 

(USA) National Fuel Gas Code NFPA 54/ANSI 

Z223.1 - latest edition or, in Canada, the CAN/

CGA-B149.1 codes - latest edition.

Install the appliance according to the regulations 

of the local authorities having jurisdiction and, 

in the USA, the National Fuel Gas Code NFPA 

54 / ANSI Z223.1 - latest edition or, in Canada, 

the CAN/CGA-B149.1 - latest edition.

Flame breadth, height and width will diminish 

4% for every 1,000 feet of altitude.

 Input (BTU) Gas Valves (all models)

All Models

Fuel 

Type

Input Rate

(BTU / HR)

Millivolt

Natural

37,500 high

30,000 low

Millivolt

Propane 34,000 high

27,000 low

Electronic

Natural

37,500

Electronic

Propane

34,000

Table 1

Burner Orifice Sizes (all models)

Elevation

Feet (meters)

Natural

Gas

drill size (inches)

Propane

Gas

drill size (inches)

0-4500

(0-1372)

#32 (0.116") 

*

37L82 •

#50 (0.070")

*

H4873 •

Table 4           

* Standard size installed at factory

                                        •  Part /Cat. Number

Содержание EBVPFNE-B

Страница 1: ...structions is not followed exactly a fire or explosion may result causing property damage personal injury or death WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLE...

Страница 2: ...le Flame Adjustment 9 Maintenance 11 Front Glass Enclosure Panel Removal and Installation 12 Install Vermiculite Embers and Logs 13 Burner Flame Appearance Sooting 16 Burner Flame Adjustments 17 Milli...

Страница 3: ...a s curit page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el contacto directo con el vidrio y prevenir las...

Страница 4: ...tact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit...

Страница 5: ...a placa del interruptor de pared para quitar el polvo y aceite Pegue la etiqueta en la superficie de la placa del interruptor que controla la chimenea Figura A Seleccione el idioma que m s se habla en...

Страница 6: ...ances This appliance is only for use with the type of gas indicated on rating plate This appliance is not convertible for use with other gases unless a certified kit is used These appliances are desig...

Страница 7: ...electronic gas control valve identified IN for the inlet and OUT for the manifold side The control valves have a 3 8 10mm NPT thread inlet and outlet side of the valve refer to Figures 2 and 3 Propan...

Страница 8: ...position until they stay there then close the door Figure 1 Control Compartment Access Millivolt Control Valve Shown Piezo Igniter Gas Valve Modesty Panel Control Compartment Access panel ON OFF Swit...

Страница 9: ...ssure Port Manifold Pressure Port OFF IN PSI ON CONTROL IGNITER Outside Combustion Air Controls Manyappliancesareequipped wheninstalled with an outside make up air vent system that is designed to prov...

Страница 10: ...be due to the opera tion of this safety limit switch First allow the appliance to cool then reset the safety switch by pushing the red reset button on it A To access the blocked flue safety switch wh...

Страница 11: ...re initial use and at least annually by a qualified service technician inspectionshouldincludeensuringthatventing system is unobstructed and vent components are properly assembled and not damaged Home...

Страница 12: ...t to gain access to the components within the firebox Removing Glass Enclosure Panels see Figure 6 Remove the top louver assembly or radiant panel To access the glass door securing latch first open th...

Страница 13: ...be used See Figure 8 DO NOT PLACE ANY VERMICULITE ON THE BURNER NOTE This appliance is provided with enough Glowing Embers for several applications do not use all that is in a new bag at one time For...

Страница 14: ...og Support Bracket Position The Groove At The Bottom Of Log 1 Over The Grate And Slide It Forward Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate He...

Страница 15: ...ont Left 55M20 4 Log Rear Right 55M21 5 Log Front Center 55M22 6 Log Center Top 55M23 2 6 5 4 1 3 Figure 10 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The R...

Страница 16: ...two extremes Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame will be orange Air shutter gap should be increased If ai...

Страница 17: ...satisfied that the burner flame appear ance is normal re install the lower control compartment door MILLIVOLT Thermocouple Hood Igniter Rod 3 8 Min 9 mm Thermopile Pilot Nozzels Millivolt Appliance Ch...

Страница 18: ...Switch Integral with Gas Valve Honeywell Electronic Gas Valve 120 VAC Primary Secondary Ju Pilot Burner Assembly BL BL Field Wired Factory Wired BK BLACK BL BLUE R RED W WHITE G GREEN BK BK BK BK BL R...

Страница 19: ...On Off Or Timer Mode Cat No Model No Description H8860 RC S 1 Remote Control G Fire Remote Simple On Off Cat No ModelNo Description H8840 KIT RC G FIRE Remote Control Cost Effective Solution Simple O...

Страница 20: ...een Kits These barrier screen kits create a barrier to prevent direct contact with the hot glass The screen panel affixes directly to the glass enclosure panel Outside Air Kits Models FOAK 4 and FOAK...

Страница 21: ...anels as shown here The panels have brick like features in relief Accessory Components CONTINUED H0779 Top Vent EBVST H0778 Top Vent EBVPF H0779 Rear Vent EBVST H0778 Rear Vent EBVPF Brickaded Panel L...

Страница 22: ...unrise Upper Grille Kit Satin Pewter SUGK40SP H3577 SLGK40C 40 Sunrise Lower Grille Kit Black H3579 40 Sunrise Lower Grille Kit Satin Pewter SLGK40SP Style View Doors Style View doors come in three st...

Страница 23: ...terior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the...

Страница 24: ...en released stop and immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control...

Страница 25: ...leuse devrait rester allum e Si elle s teint r p tez les tapes 5 8 inclusivement Si la manette ne se soul ve pas d elle m me lorsqu on la rel che arr ter et appeler imm diatement un technicien qualifi...

Страница 26: ...rce OPERATING INSTRUCTIONS 1 If applicable Set the thermostat to lowest setting Turn wall on off switch unit mounted on off switch or remote control switch OFF 2 Turn OFF all electric power to the app...

Страница 27: ...S il n y a pas d odeur de gaz passez l tape suivante INSTRUCTIONS DE MISE EN MARCHE 1 Si applicable R glez le thermostat la temp rature la plus basse Tournez l interrupteur murale l interrupteur sur...

Страница 28: ...ote switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch or timer or remote c...

Страница 29: ...4Vhotand 24V common leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identifyproperlead thischeckmust be done with the valve control con nected and igniter powered...

Страница 30: ...sembly Black 40 H6342 2 2 7 Nameplate Brand 12L15 2 2 8 Log Set 55M04 1 1 9a Bag of Vermiculite H6319 1 1 9b Bag of Embers Rockwool 88L53 1 1 9c Bag of Decorative Volcanic Stone 80L42 1 1 10 Magnet Ra...

Страница 31: ...rts 2b 4b 5b 6b 1b 3b 42 7 10 11 15 31 37 43 41 45 32 33 12 50 14 44 13 35 36 9b 8 34 1a 2a 3a 4a 5a 6a 10 Cabinet Corner Post Location 17 9a 16 Inside Location 40 30 NOTE EBVPF Shown see the tables o...

Страница 32: ...ials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LENNOX the LENNOX design DAVE LENNOX the image of DAVE LENNO...

Отзывы: