Lennox Hearth Products EBVPFNE-B Скачать руководство пользователя страница 28

28

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

TROUBLESHOOTING GUIDE - MILLIVOLT GAS CONTROL SYSTEM

NOTE: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, iff applicable), 

is in the “ON” position.
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.

SYMPTOM

POSSIBLE CAUSES

CORRECTIVE ACTION

1.

  Spark igniter will not light pilot after 

repeated triggering of igniter button.

  WARNING: if the pilot will not light 

after 1 minute of attempting, wait 

for at least 5 minutes for gas to 

clear before attempting again.

A.

  Defective igniter

  (no spark at electrode).

Check for spark at electrode and pilot; if no spark and 

electrode wire is properly connected, replace igniter.

B.

  Defective or misaligned electrode at pilot 

(spark at electrode).

Using a match, light pilot. If pilot lights, turn off pilot 

and trigger the igniter button again. If pilot lights, an 

improper gas mixture caused the bad lighting and a 

longer purge period is recommended. If pilot will not 

light – check gap at electrode and pilot – should be 1/8" 

to have a strong spark. If gap measures 1/8", replace 

pilot (see 

Figures 13 or 14 

on 

Page 12)

.

C.

  Gas supply pressure errant.

Check inlet gas pressure. It should be within the limits 

as marked on the rating plate.

D.

  Pilot orifice plugged.

Clean or replace pilot orifice.

2.

  Pilot will not stay lit after  

carefully following the lighting 

instructions.

A.

  Defective pilot generator 

(thermocouple).

Check pilot flame, it must impinge on thermocouple  

(see 

Figures 13 or 14 

on 

Page 12

).  Clean and/or 

adjust pilot for maximum flame impingement on 

thermocouple. Ensure that the connection between 

the valve and thermocouple are tight and secure.

3.

  Pilot burning, no gas to burner, Valve 

knob “ON,” and the (standard) burner 

OFF/ON switch is “ON."  Read impor-

tant note below.

 

IMPORTANT NOTE: If an optional 

*remote switch is used for burner 

operation, if the standard burner 

OFF/ON switch is still installed on 

appliance it must be in the "OFF" 

position.

 *

Optional remote switch kits - wall 

switch or timer, or remote control.

A.

  Wall switch or wires defective.

Check wall switch and wires for proper connections. 

Jumper wire across terminals at wall switch, if burner 

comes on, replace defective wall switch. If okay, jumper 

wires across wall switch wires at valve, if burner comes 

on, wires are faulty or connections are bad.

B.

  Thermopile may not be generating suf-

ficient millivolts.

Check thermopile with millivolt meter. Take reading 

at thermopile terminals of gas valve. Should read 

325 millivolts minimum with optional wall switch 

“OFF.” Replace faulty thermopile if reading is below 

specified minimum.

C.

  Plugged burner orifice.

Check burner orifice for blockage and remove.

D.

  OFF/ON Switch & *Remote Switch are in 

the "ON" position resulting in excessive 

resistance.

When turning on the burner using a *remote switch, 

ensure that the standard OFF/ON switch is in the "OFF" 

position.  If both switches are in the ON position, it 

may result in excessive resistance (& millivolt drain-

age) and the burner may not come on.

4.

  Frequent pilot/burner outage prob-

lem.

A.

  Pilot flame may be too low or blowing (high) 

causing the pilot/valve safety to drop out.

Clean and/or adjust pilot flame for maximum flame 

impingement on thermocouple  (see 

Figures 13 or 

14 

on 

Page 12

).

SYMPTOM

POSSIBLE CAUSES

CORRECTIVE ACTION

1.

  Burner will not light.

A.

  Faulty Valve System.

See 

Page 29

.

B.

  “OFF/ON” or wall switch defective.

Disconnect the two black wires from the wire nuts. 

Test switch(s) for continuity with a multimeter. If 

continuity is not indicated, switch(s) is defective and 

must be replaced.

Note: 

Before replacing “OFF/ON” switch, Ensure to 

check wiring for loose connections or broken wires 

and repair as needed.

2.

  Burners come “ON,” then turns “OFF.”

A.

  Burner orifice plugged.

Check main burner orifice(s) for blockage. Clean 

or replace.

B.

  Obstructed vent system.

Check vent system for obstructions.  

TROUBLESHOOTING

TROUBLESHOOTING GUIDE - ELECTRONIC IGNITION SYSTEM

Содержание EBVPFNE-B

Страница 1: ...structions is not followed exactly a fire or explosion may result causing property damage personal injury or death WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLE...

Страница 2: ...le Flame Adjustment 9 Maintenance 11 Front Glass Enclosure Panel Removal and Installation 12 Install Vermiculite Embers and Logs 13 Burner Flame Appearance Sooting 16 Burner Flame Adjustments 17 Milli...

Страница 3: ...a s curit page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el contacto directo con el vidrio y prevenir las...

Страница 4: ...tact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit...

Страница 5: ...a placa del interruptor de pared para quitar el polvo y aceite Pegue la etiqueta en la superficie de la placa del interruptor que controla la chimenea Figura A Seleccione el idioma que m s se habla en...

Страница 6: ...ances This appliance is only for use with the type of gas indicated on rating plate This appliance is not convertible for use with other gases unless a certified kit is used These appliances are desig...

Страница 7: ...electronic gas control valve identified IN for the inlet and OUT for the manifold side The control valves have a 3 8 10mm NPT thread inlet and outlet side of the valve refer to Figures 2 and 3 Propan...

Страница 8: ...position until they stay there then close the door Figure 1 Control Compartment Access Millivolt Control Valve Shown Piezo Igniter Gas Valve Modesty Panel Control Compartment Access panel ON OFF Swit...

Страница 9: ...ssure Port Manifold Pressure Port OFF IN PSI ON CONTROL IGNITER Outside Combustion Air Controls Manyappliancesareequipped wheninstalled with an outside make up air vent system that is designed to prov...

Страница 10: ...be due to the opera tion of this safety limit switch First allow the appliance to cool then reset the safety switch by pushing the red reset button on it A To access the blocked flue safety switch wh...

Страница 11: ...re initial use and at least annually by a qualified service technician inspectionshouldincludeensuringthatventing system is unobstructed and vent components are properly assembled and not damaged Home...

Страница 12: ...t to gain access to the components within the firebox Removing Glass Enclosure Panels see Figure 6 Remove the top louver assembly or radiant panel To access the glass door securing latch first open th...

Страница 13: ...be used See Figure 8 DO NOT PLACE ANY VERMICULITE ON THE BURNER NOTE This appliance is provided with enough Glowing Embers for several applications do not use all that is in a new bag at one time For...

Страница 14: ...og Support Bracket Position The Groove At The Bottom Of Log 1 Over The Grate And Slide It Forward Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate He...

Страница 15: ...ont Left 55M20 4 Log Rear Right 55M21 5 Log Front Center 55M22 6 Log Center Top 55M23 2 6 5 4 1 3 Figure 10 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The R...

Страница 16: ...two extremes Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame will be orange Air shutter gap should be increased If ai...

Страница 17: ...satisfied that the burner flame appear ance is normal re install the lower control compartment door MILLIVOLT Thermocouple Hood Igniter Rod 3 8 Min 9 mm Thermopile Pilot Nozzels Millivolt Appliance Ch...

Страница 18: ...Switch Integral with Gas Valve Honeywell Electronic Gas Valve 120 VAC Primary Secondary Ju Pilot Burner Assembly BL BL Field Wired Factory Wired BK BLACK BL BLUE R RED W WHITE G GREEN BK BK BK BK BL R...

Страница 19: ...On Off Or Timer Mode Cat No Model No Description H8860 RC S 1 Remote Control G Fire Remote Simple On Off Cat No ModelNo Description H8840 KIT RC G FIRE Remote Control Cost Effective Solution Simple O...

Страница 20: ...een Kits These barrier screen kits create a barrier to prevent direct contact with the hot glass The screen panel affixes directly to the glass enclosure panel Outside Air Kits Models FOAK 4 and FOAK...

Страница 21: ...anels as shown here The panels have brick like features in relief Accessory Components CONTINUED H0779 Top Vent EBVST H0778 Top Vent EBVPF H0779 Rear Vent EBVST H0778 Rear Vent EBVPF Brickaded Panel L...

Страница 22: ...unrise Upper Grille Kit Satin Pewter SUGK40SP H3577 SLGK40C 40 Sunrise Lower Grille Kit Black H3579 40 Sunrise Lower Grille Kit Satin Pewter SLGK40SP Style View Doors Style View doors come in three st...

Страница 23: ...terior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the...

Страница 24: ...en released stop and immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control...

Страница 25: ...leuse devrait rester allum e Si elle s teint r p tez les tapes 5 8 inclusivement Si la manette ne se soul ve pas d elle m me lorsqu on la rel che arr ter et appeler imm diatement un technicien qualifi...

Страница 26: ...rce OPERATING INSTRUCTIONS 1 If applicable Set the thermostat to lowest setting Turn wall on off switch unit mounted on off switch or remote control switch OFF 2 Turn OFF all electric power to the app...

Страница 27: ...S il n y a pas d odeur de gaz passez l tape suivante INSTRUCTIONS DE MISE EN MARCHE 1 Si applicable R glez le thermostat la temp rature la plus basse Tournez l interrupteur murale l interrupteur sur...

Страница 28: ...ote switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch or timer or remote c...

Страница 29: ...4Vhotand 24V common leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identifyproperlead thischeckmust be done with the valve control con nected and igniter powered...

Страница 30: ...sembly Black 40 H6342 2 2 7 Nameplate Brand 12L15 2 2 8 Log Set 55M04 1 1 9a Bag of Vermiculite H6319 1 1 9b Bag of Embers Rockwool 88L53 1 1 9c Bag of Decorative Volcanic Stone 80L42 1 1 10 Magnet Ra...

Страница 31: ...rts 2b 4b 5b 6b 1b 3b 42 7 10 11 15 31 37 43 41 45 32 33 12 50 14 44 13 35 36 9b 8 34 1a 2a 3a 4a 5a 6a 10 Cabinet Corner Post Location 17 9a 16 Inside Location 40 30 NOTE EBVPF Shown see the tables o...

Страница 32: ...ials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LENNOX the LENNOX design DAVE LENNOX the image of DAVE LENNO...

Отзывы: