Lennox Hearth Products EBVPFNE-B Скачать руководство пользователя страница 17

17

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

     

WARNING

 

Air shutter adjustment should 

only be performed by a quali-

fied professional service tech-

nician.

 

Ensure glass enclosure panels 

are in place and sealed during 

adjustment.

     

CAUTION

 

Soot will be produced if the 

air shutter is closed too much.  

Any damage due to sooting, 

resulting from improperly 

setting the air shutter, is not 

covered under the warranty.

• 

 

The air shutter door and 

nearby appliance surfaces 

are hot.  Exercise caution to 

avoid injury while adjusting 

flame appearance.

1

. Refer to 

Figure 11 

 for proper flame ap-

pearance.  To adjust the flame, rotate the 

adjustment rod  toward the back or toward 

the front of the fireplace (rod located in the 

lower control area). Position the air shutter 

to the factory setting as shown in the table 

in 

Figure 12

2.

  Light appliance (follow lighting procedure on 

lighting label in control compartment or see 

lighting instructions on 

Pages 26 through 

29

).

3. 

Allow the burner to operate for at least 15 

minutes while observing the flame continu-

ously to ensure that the proper flame ap-

pearance has been achieved If the following 

conditions are present, adjust accordingly.  

  •   If flame appears weak or sooty, adjust 

the air shutter, incrementally, to a more 

open position until the proper flame 

appearance is achieved.

  •   If  flame  remains  blue,  adjust  the  air 

shutter, incrementally, to a more closed 

position until the proper flame appear-

ance is achieved.

4.

  Leave the control knob (off/pilot/on) in the 

ON position (millivolt appliances) and the 

burner OFF/ON switch OFF (and remote 

switches, if applicable). 

5. 

When satisfied that the burner flame appear-

ance is normal, re-install the lower control 

compartment door.  

MILLIVOLT
Thermocouple

Hood Igniter Rod

3/8" Min

(9 mm)

Thermopile

Pilot

Nozzels

Millivolt Appliance Checkout

The pilot flame should be steady, not lifting 

or floating. Flame should be blue in color with 

traces of orange at the outer edge.

The top 3/8" (10 mm) at the pilot generator 

(thermopile) and the top 1/8" minimum (tip) 

of the quick drop out thermocouple should be 

engulfed in the pilot flame. 

The flame should project 1" (25 mm) beyond 

the hood at all three ports  (see 

Figure 13

)

.  

 

Replace logs if removed for pilot inspection.

To light the burner; turn “ON” the control 

switch and rotate the gas valve control knob 

counterclockwise to the “ON” position (“ON” 

will be at the top side of the valve).

Electronic Appliance Checkout

To light the burner, turn ‘ON’ the unit mounted 

On/Off switch or the optional control switch.  

Ensure the igniter lights the pilot.  The pilot 

flame should engulf the flame rod as shown 

in 

Figure 14

.

Figure 13

ELECTRONIC

Proper Flame

Adjustment

Pilot

Nozzle

3/8” to 1/2”

(9 mm to 13 mm)

Ground

Electrode

Flame Rod

Hot Surface

Igniter

Figure 14

Burner Flame Adjustments 

Adjustment Rod Positions (when viewed from above)

Figure 12

Air Shutter

Adjusting

Rod

Orifice

Increase Shutter

 Opening In This

Direction

Decrease Shutter

Opening In This

Direction

Note - Burners are omitted in this view for clarity.

R

E

N

R

U

B

N

I

A

M

G

N

I

T

T

E

S

R

E

T

T

U

H

S

Y

R

O

T

C

A

F

G

N

I

T

T

E

S

R

E

T

T

U

H

S

Y

R

O

T

C

A

F

G

N

I

T

T

E

S

R

E

T

T

U

H

S

Y

R

O

T

C

A

F

G

N

I

T

T

E

S

R

E

T

T

U

H

S

Y

R

O

T

C

A

F

G

N

I

T

T

E

S

R

E

T

T

U

H

S

Y

R

O

T

C

A

F

s

l

e

d

o

M

s

a

G

l

a

r

u

t

a

N

s

e

h

c

n

i

)

m

m

(

e

n

a

p

o

r

P

s

a

G

s

e

h

c

n

i

)

m

m

(

T

S

V

B

E

F

P

V

B

E

6

1

/

1

)

5

.

1

(

1

1

(

6

1

/

7

)

Содержание EBVPFNE-B

Страница 1: ...structions is not followed exactly a fire or explosion may result causing property damage personal injury or death WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLE...

Страница 2: ...le Flame Adjustment 9 Maintenance 11 Front Glass Enclosure Panel Removal and Installation 12 Install Vermiculite Embers and Logs 13 Burner Flame Appearance Sooting 16 Burner Flame Adjustments 17 Milli...

Страница 3: ...a s curit page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el contacto directo con el vidrio y prevenir las...

Страница 4: ...tact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit...

Страница 5: ...a placa del interruptor de pared para quitar el polvo y aceite Pegue la etiqueta en la superficie de la placa del interruptor que controla la chimenea Figura A Seleccione el idioma que m s se habla en...

Страница 6: ...ances This appliance is only for use with the type of gas indicated on rating plate This appliance is not convertible for use with other gases unless a certified kit is used These appliances are desig...

Страница 7: ...electronic gas control valve identified IN for the inlet and OUT for the manifold side The control valves have a 3 8 10mm NPT thread inlet and outlet side of the valve refer to Figures 2 and 3 Propan...

Страница 8: ...position until they stay there then close the door Figure 1 Control Compartment Access Millivolt Control Valve Shown Piezo Igniter Gas Valve Modesty Panel Control Compartment Access panel ON OFF Swit...

Страница 9: ...ssure Port Manifold Pressure Port OFF IN PSI ON CONTROL IGNITER Outside Combustion Air Controls Manyappliancesareequipped wheninstalled with an outside make up air vent system that is designed to prov...

Страница 10: ...be due to the opera tion of this safety limit switch First allow the appliance to cool then reset the safety switch by pushing the red reset button on it A To access the blocked flue safety switch wh...

Страница 11: ...re initial use and at least annually by a qualified service technician inspectionshouldincludeensuringthatventing system is unobstructed and vent components are properly assembled and not damaged Home...

Страница 12: ...t to gain access to the components within the firebox Removing Glass Enclosure Panels see Figure 6 Remove the top louver assembly or radiant panel To access the glass door securing latch first open th...

Страница 13: ...be used See Figure 8 DO NOT PLACE ANY VERMICULITE ON THE BURNER NOTE This appliance is provided with enough Glowing Embers for several applications do not use all that is in a new bag at one time For...

Страница 14: ...og Support Bracket Position The Groove At The Bottom Of Log 1 Over The Grate And Slide It Forward Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate He...

Страница 15: ...ont Left 55M20 4 Log Rear Right 55M21 5 Log Front Center 55M22 6 Log Center Top 55M23 2 6 5 4 1 3 Figure 10 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The R...

Страница 16: ...two extremes Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame will be orange Air shutter gap should be increased If ai...

Страница 17: ...satisfied that the burner flame appear ance is normal re install the lower control compartment door MILLIVOLT Thermocouple Hood Igniter Rod 3 8 Min 9 mm Thermopile Pilot Nozzels Millivolt Appliance Ch...

Страница 18: ...Switch Integral with Gas Valve Honeywell Electronic Gas Valve 120 VAC Primary Secondary Ju Pilot Burner Assembly BL BL Field Wired Factory Wired BK BLACK BL BLUE R RED W WHITE G GREEN BK BK BK BK BL R...

Страница 19: ...On Off Or Timer Mode Cat No Model No Description H8860 RC S 1 Remote Control G Fire Remote Simple On Off Cat No ModelNo Description H8840 KIT RC G FIRE Remote Control Cost Effective Solution Simple O...

Страница 20: ...een Kits These barrier screen kits create a barrier to prevent direct contact with the hot glass The screen panel affixes directly to the glass enclosure panel Outside Air Kits Models FOAK 4 and FOAK...

Страница 21: ...anels as shown here The panels have brick like features in relief Accessory Components CONTINUED H0779 Top Vent EBVST H0778 Top Vent EBVPF H0779 Rear Vent EBVST H0778 Rear Vent EBVPF Brickaded Panel L...

Страница 22: ...unrise Upper Grille Kit Satin Pewter SUGK40SP H3577 SLGK40C 40 Sunrise Lower Grille Kit Black H3579 40 Sunrise Lower Grille Kit Satin Pewter SLGK40SP Style View Doors Style View doors come in three st...

Страница 23: ...terior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the...

Страница 24: ...en released stop and immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control...

Страница 25: ...leuse devrait rester allum e Si elle s teint r p tez les tapes 5 8 inclusivement Si la manette ne se soul ve pas d elle m me lorsqu on la rel che arr ter et appeler imm diatement un technicien qualifi...

Страница 26: ...rce OPERATING INSTRUCTIONS 1 If applicable Set the thermostat to lowest setting Turn wall on off switch unit mounted on off switch or remote control switch OFF 2 Turn OFF all electric power to the app...

Страница 27: ...S il n y a pas d odeur de gaz passez l tape suivante INSTRUCTIONS DE MISE EN MARCHE 1 Si applicable R glez le thermostat la temp rature la plus basse Tournez l interrupteur murale l interrupteur sur...

Страница 28: ...ote switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch or timer or remote c...

Страница 29: ...4Vhotand 24V common leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identifyproperlead thischeckmust be done with the valve control con nected and igniter powered...

Страница 30: ...sembly Black 40 H6342 2 2 7 Nameplate Brand 12L15 2 2 8 Log Set 55M04 1 1 9a Bag of Vermiculite H6319 1 1 9b Bag of Embers Rockwool 88L53 1 1 9c Bag of Decorative Volcanic Stone 80L42 1 1 10 Magnet Ra...

Страница 31: ...rts 2b 4b 5b 6b 1b 3b 42 7 10 11 15 31 37 43 41 45 32 33 12 50 14 44 13 35 36 9b 8 34 1a 2a 3a 4a 5a 6a 10 Cabinet Corner Post Location 17 9a 16 Inside Location 40 30 NOTE EBVPF Shown see the tables o...

Страница 32: ...ials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LENNOX the LENNOX design DAVE LENNOX the image of DAVE LENNO...

Отзывы: