NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing 

property damage, personal injury or loss of life. 

A. This appliance has a pilot which must be lighted by a piezo 

igniter.  When lighting the pilot, follow these instructions 

exactly.

B. BEFORE LIGHTING smell all around the appliance area for 

gas. Be sure to smell next to the floor because some gas is 

heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:
•  Do not try to light any appliance.

•  Do not touch any electric switch; do not use any phone in your 

building.

1.  STOP! Read the safety information above on this label.
2.  (If applicable) Set the thermostat to lowest setting. Turn wall on/off 

switch, unit mounted on/off switch or remote control switch "OFF."

3.  Turn OFF all electric power to the appliance.
4.  Access the control compartment.
5.  Push in gas control knob slightly and turn clockwise              to "OFF."  
   NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is 

pushed in slightly.  Do Not force.

6.  Wait five (5) minutes to clear out any gas.  Then smell for gas, 

including near the floor.  If you smell gas, STOP! Follow "B" in the 

safety information above on this label.  If you don't smell gas, go to the 

next step.

7.  Find pilot - located in firebox on the same plane as the top of the burner.
8.  Turn knob on gas control counterclockwise               to "PILOT."
9.  Push in control knob all the way and hold in.  Immediately light the pilot 

by triggering the piezo igniter (pushing the button) until pilot lights.  

Continue to hold the control knob in for about 1-1/2 minutes after the 

pilot is lit.  Release knob and it will pop back up.  Pilot should remain 

lit.  If it goes out, repeat steps 5 through 9.

•   If knob does not pop up when released, stop and immediately call 

your service technician or gas supplier.

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE

•   If the pilot will not stay lit after several tries, turn the gas control 

knob to "OFF" and call your service technician or gas supplier.

10. Turn gas control knob counterclockwise             to "ON."
11. Close control compartment.
12. (If applicable) Turn on all electrical power to the appliance.
13. (If applicable) Set thermostat to desired setting. Turn wall on/off switch, 

unit mounted on/off switch or remote control switch "ON."

WARNING

HOT GLASS WILL  CAUSE BURNS.

DO NOT TOUCH GLASS  UNTIL COOLED.

NEVER ALLOW CHILDREN TO TOUCH GLASS.

•  Immediately call your gas supplier from a neighbor’s phone. 

Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. 

Never use tools. If the knob will not push in or turn by hand, 

don’t try to repair it, call a qualified service technician. Force 

or attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 

appliance and to replace any part of the control system and 

any gas control which has been under water.

4. 

Push in gas control knob slightly and turn clockwise              to "OFF."  Do 

not force.

5. Close the main line gas shut-off valve.

6. Close control compartment.

Pilot Assemblies

H I

LO

W

TPTH

TP

TH

PIL

OT

PI

LO

T

ON

it

OFF

OUT

IN

LO

HI

IN

OUT

OFF

PILO

T

ON

PILOT

ON

OFF

PI

LO

T

L

O

HI

HI

L O W

HT

PT

HT

PT

PILO

T

PIL

OT

ON

ti

OFF

OUT

IN

Gas Control Valves

SIT

Robertshaw

Gas Control Knobs

Honeywell

P/N 62L2901_5

1. (If applicable) Set the thermostat to lowest setting. Turn wall on/off 

switch, unit mounted on/off switch or remote control switch "OFF." 

2. 

 Turn OFF all electric power to the appliance, if service is to be 

performed.

3. 

Access the control compartment.

LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE

Содержание EBVPFNE-B

Страница 1: ...structions is not followed exactly a fire or explosion may result causing property damage personal injury or death WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLE...

Страница 2: ...le Flame Adjustment 9 Maintenance 11 Front Glass Enclosure Panel Removal and Installation 12 Install Vermiculite Embers and Logs 13 Burner Flame Appearance Sooting 16 Burner Flame Adjustments 17 Milli...

Страница 3: ...a s curit page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el contacto directo con el vidrio y prevenir las...

Страница 4: ...tact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit...

Страница 5: ...a placa del interruptor de pared para quitar el polvo y aceite Pegue la etiqueta en la superficie de la placa del interruptor que controla la chimenea Figura A Seleccione el idioma que m s se habla en...

Страница 6: ...ances This appliance is only for use with the type of gas indicated on rating plate This appliance is not convertible for use with other gases unless a certified kit is used These appliances are desig...

Страница 7: ...electronic gas control valve identified IN for the inlet and OUT for the manifold side The control valves have a 3 8 10mm NPT thread inlet and outlet side of the valve refer to Figures 2 and 3 Propan...

Страница 8: ...position until they stay there then close the door Figure 1 Control Compartment Access Millivolt Control Valve Shown Piezo Igniter Gas Valve Modesty Panel Control Compartment Access panel ON OFF Swit...

Страница 9: ...ssure Port Manifold Pressure Port OFF IN PSI ON CONTROL IGNITER Outside Combustion Air Controls Manyappliancesareequipped wheninstalled with an outside make up air vent system that is designed to prov...

Страница 10: ...be due to the opera tion of this safety limit switch First allow the appliance to cool then reset the safety switch by pushing the red reset button on it A To access the blocked flue safety switch wh...

Страница 11: ...re initial use and at least annually by a qualified service technician inspectionshouldincludeensuringthatventing system is unobstructed and vent components are properly assembled and not damaged Home...

Страница 12: ...t to gain access to the components within the firebox Removing Glass Enclosure Panels see Figure 6 Remove the top louver assembly or radiant panel To access the glass door securing latch first open th...

Страница 13: ...be used See Figure 8 DO NOT PLACE ANY VERMICULITE ON THE BURNER NOTE This appliance is provided with enough Glowing Embers for several applications do not use all that is in a new bag at one time For...

Страница 14: ...og Support Bracket Position The Groove At The Bottom Of Log 1 Over The Grate And Slide It Forward Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate He...

Страница 15: ...ont Left 55M20 4 Log Rear Right 55M21 5 Log Front Center 55M22 6 Log Center Top 55M23 2 6 5 4 1 3 Figure 10 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The R...

Страница 16: ...two extremes Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame will be orange Air shutter gap should be increased If ai...

Страница 17: ...satisfied that the burner flame appear ance is normal re install the lower control compartment door MILLIVOLT Thermocouple Hood Igniter Rod 3 8 Min 9 mm Thermopile Pilot Nozzels Millivolt Appliance Ch...

Страница 18: ...Switch Integral with Gas Valve Honeywell Electronic Gas Valve 120 VAC Primary Secondary Ju Pilot Burner Assembly BL BL Field Wired Factory Wired BK BLACK BL BLUE R RED W WHITE G GREEN BK BK BK BK BL R...

Страница 19: ...On Off Or Timer Mode Cat No Model No Description H8860 RC S 1 Remote Control G Fire Remote Simple On Off Cat No ModelNo Description H8840 KIT RC G FIRE Remote Control Cost Effective Solution Simple O...

Страница 20: ...een Kits These barrier screen kits create a barrier to prevent direct contact with the hot glass The screen panel affixes directly to the glass enclosure panel Outside Air Kits Models FOAK 4 and FOAK...

Страница 21: ...anels as shown here The panels have brick like features in relief Accessory Components CONTINUED H0779 Top Vent EBVST H0778 Top Vent EBVPF H0779 Rear Vent EBVST H0778 Rear Vent EBVPF Brickaded Panel L...

Страница 22: ...unrise Upper Grille Kit Satin Pewter SUGK40SP H3577 SLGK40C 40 Sunrise Lower Grille Kit Black H3579 40 Sunrise Lower Grille Kit Satin Pewter SLGK40SP Style View Doors Style View doors come in three st...

Страница 23: ...terior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the...

Страница 24: ...en released stop and immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control...

Страница 25: ...leuse devrait rester allum e Si elle s teint r p tez les tapes 5 8 inclusivement Si la manette ne se soul ve pas d elle m me lorsqu on la rel che arr ter et appeler imm diatement un technicien qualifi...

Страница 26: ...rce OPERATING INSTRUCTIONS 1 If applicable Set the thermostat to lowest setting Turn wall on off switch unit mounted on off switch or remote control switch OFF 2 Turn OFF all electric power to the app...

Страница 27: ...S il n y a pas d odeur de gaz passez l tape suivante INSTRUCTIONS DE MISE EN MARCHE 1 Si applicable R glez le thermostat la temp rature la plus basse Tournez l interrupteur murale l interrupteur sur...

Страница 28: ...ote switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch or timer or remote c...

Страница 29: ...4Vhotand 24V common leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identifyproperlead thischeckmust be done with the valve control con nected and igniter powered...

Страница 30: ...sembly Black 40 H6342 2 2 7 Nameplate Brand 12L15 2 2 8 Log Set 55M04 1 1 9a Bag of Vermiculite H6319 1 1 9b Bag of Embers Rockwool 88L53 1 1 9c Bag of Decorative Volcanic Stone 80L42 1 1 10 Magnet Ra...

Страница 31: ...rts 2b 4b 5b 6b 1b 3b 42 7 10 11 15 31 37 43 41 45 32 33 12 50 14 44 13 35 36 9b 8 34 1a 2a 3a 4a 5a 6a 10 Cabinet Corner Post Location 17 9a 16 Inside Location 40 30 NOTE EBVPF Shown see the tables o...

Страница 32: ...ials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LENNOX the LENNOX design DAVE LENNOX the image of DAVE LENNO...

Отзывы: