DirecDoor Installation Guide

Содержание DirecDoor

Страница 1: ...7 4 DirecDoor Installation Guide...

Страница 2: ...D Technologies Inc ALL RIGHTS RESERVED Active Directory Microsoft SQL Server Windows and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and...

Страница 3: ...ROL INCLUDING BUT NOT LIMITED TO INTERNET CELLULAR AND LANDLINE CONNECTIVITY MOBILE DEVICE AND RELATED OPERATING SYSTEM COMPATABILITY OR PROPER INSTALLATION CONFIGURATION AND MAINTENANCE OF AUTHORIZED...

Страница 4: ......

Страница 5: ...Prevention Procedures 17 Signal Transmission 17 Cable Routing 17 Cable Length 17 Mounting 17 Mounting and Handling Guidelines 17 Mounting Instructions 18 Determining Power Requirements 20 CHAPTER 3 P...

Страница 6: ...ng the DIP Switches 37 Setting the Jumpers 39 Wiring the Readers 39 Wiring the Digital Inputs DIs 43 Wiring the Door Strikes 44 Wiring the Fire Alarm Control Panel 46 CHAPTER 6 DDIO Interface 47 Direc...

Страница 7: ...ler Parameters Menu Other Parameters Form 71 Disable Enable the Integrated Configuration Tool ICT 72 Upgrading the Controller Firmware 72 Configuration Checklist for the Integrated Configuration Tool...

Страница 8: ...Table of Contents 8 DirecDoor Installation Guide...

Страница 9: ...buted processing for the interface of access control readers keypads alarm inputs and outputs back to a host system computer This distributed processing allows each DirecDoor controller to operate ind...

Страница 10: ...fications For UL compliant installations refer to UL Compliance on page 80 Enclosure Specifications Physical dimensions 10 15 inches high x 9 15 inches wide x 3 04 inches deep 258 mm high x 232 mm wid...

Страница 11: ...y and alarm cable commercial applications shielded plenum rated Controller to DIs or DOs Use any cable with the desired number of individually shielded pairs Devices Readers Number supported maximum o...

Страница 12: ...90 Model T720 reader 12 75 0 90 Model T725 reader 12 110 1 32 Securitron M62 Magnalock strikea 12 240 2 88 Securitron M62 Magnalock strikea a When using magnetic strikes with auto voltage select addit...

Страница 13: ...a Type 3 SIMMb Operating system uClinux 2 6 uClinux 2 6 Processor Xilinx MicroBlaze Xilinx MicroBlaze RAM 32 MB 64 MB Flash memory 32 MB 32 MB Host Application and Capacities All currently supported v...

Страница 14: ...Introduction 14 DirecDoor Installation Guide...

Страница 15: ...ply power to any component until the installation is complete Damage to components may occur if power is incorrectly applied 1 Determine the cable clamps needed and obtain them before starting the ins...

Страница 16: ...be produced when walking across a carpet and touching a board for example Before handling any board make sure you dissipate your body s charge by touching ground This discharges any static electricit...

Страница 17: ...ve machinery such as air conditioners elevators escalators large blowers and machine tools Electromagnetic equipment such as degaussers magnetic chucks etc Control equipment relays for machinery and o...

Страница 18: ...direct sunlight To avoid mechanical damage do not drop or stack boards Do not subject printed circuit boards to electrostatic discharge Mounting Instructions Mount the controller cabinet using the fol...

Страница 19: ...DirecDoor Installation Guide 19 Mounting DirecDoor Mounting Template...

Страница 20: ...Guide DirecDoor Controller and Components in Standard Enclosure Determining Power Requirements Use the DirecDoor Wattage Calculator worksheet below to help plan your installation An Excel XLS version...

Страница 21: ...If this is a UL Listed installation refer to Regulatory Information on page 77 Note The DDSDC does not support the optional dial up modem or DirecDoor I O expansion board as shown below in the wattag...

Страница 22: ...Installation Planning and Mounting 22 DirecDoor Installation Guide...

Страница 23: ...ng power Network Connector J10 as Power over Ethernet PoE Auxiliary Power Connector J8 with 24 VDC supply and battery backup J8 Power Input Port Connector J8 Pin Signal Name 1 24 VDC Auxiliary Power I...

Страница 24: ...upplied ferrite to the network cable as shown in figure Installing Ferrite on page 78 3 Connect the network cable to J10 on the DirecDoor board Note By Ethernet standards the maximum cable length is l...

Страница 25: ...WARNING Do not ground both cable ends Note If the polarity is reversed the fuse blows to prevent damage If the fuse blows it automatically resets within approximately 5 seconds 3 Install the cabinet g...

Страница 26: ...n has not been evaluated by UL at this time Connect AC power fail input from a battery backup unit to connector J8 between pin 2 Gnd or pin 4 Gnd and pin 3 AC fail The battery backup unit must supply...

Страница 27: ...ng network protocols DHCP and UDP Provides nonvolatile storage referred to as persistent mode of operation This means a faster reset recovery and allows for host less operation Utilizes a 32 bit platf...

Страница 28: ...ecDoor Board 28 DirecDoor Installation Guide DirecDoor Board Layout Note The DDSDC does not have the following hardware components as shown in the figure above Connectors J4 J5 J7 and J11 and Switch S...

Страница 29: ...o five 5 seconds for D19 to turn ON Once D19 is ON release SW4 D19 turns OFF once the Integrated Configuration Tool has been manually enabled SW5 Hardware Reset Reboots the DirecDoor board The switch...

Страница 30: ...O Notes The DDSDC does not have Connector J5 and does not support the DDIO Not evaluated by UL at this time J6 Connector J6 is a pluggable screw terminal block For connector J6 pinouts refer to table...

Страница 31: ...or J10 is an RJ45 Standard Cat 5 jack which controls the RJ45 network connection J11 Not Used Connector J11 is an RJ11 standard telephone jack Note The DDSDC does not have Connector J11 J9 Console Por...

Страница 32: ...oller decoded a badge read and determined that it was a valid badge Waiting for database D17 Flashes the controller is waiting to receive database from host Restore defaults requested D17 and D21 On i...

Страница 33: ...mode Controller offline ON Address received ON Badge read ON Waiting for panel configuration Flashesa a For OnGuard systems D17 blinks twice followed by a one second delay before repeating Restore def...

Страница 34: ...lash write Flashes Manual ICT Enable ON Watch dog failure mode ON OFF Input LEDs on the DirecDoor Board LED Number Name Description D24 FACP Fire Alarm Connection Point ON Open OFF Closed D25 Door Con...

Страница 35: ...sts for approximately 40 to 45 seconds after which the system will auto restart D27 Door Contact 2 Indicates physical input state ON Closed OFF Open Flashing Fault D28 Door REX 2 Indicates physical in...

Страница 36: ...following products use this port Integrated Configuration Tool DirecDoor M5PXNplus M2000PXNplus M3000PXNplus Configuring Upstream Communications with the Host 1 Verify that you have a working network...

Страница 37: ...o only one type of reader technology Wiegand F 2F or Supervised F 2F The reader interface has built in pull up resistors to accommodate cable lengths over 500 feet 152 40 m External pull up resistors...

Страница 38: ...vised F 2F default ON ON Magstripe Strobed ON ON Magstripe F 2F ON ON ON Wiegand format a ON a Use the OnGuard application to configure the specific Wiegand card formats OFF Supervised DI REX SW1 7 Su...

Страница 39: ...e to the grounding nuts provided outside the controller enclosure Refer to figure Wiring to Wiegand Readers Door Contacts and Exit Request on page 42 4 Place the appropriate wires to the appropriate s...

Страница 40: ...t DI on Connector J2 Refer to figure Wiring to Wiegand Readers Door Contacts and Exit Request on page 42 J1 J3 Connecting T 5xx Series Reader J1 J3 Pin Signal Name Reader Pigtail Colors 1 12 VDC Red 2...

Страница 41: ...lay Power on page 45 and figure Wiring Door Strikes External Relay Power on page 45 Dressing the Reader DO DI Wiring Inside the DirecDoor Enclosure 7 Door Strike Relay Common Com Brown 8 Door Strike R...

Страница 42: ...ader Interface 42 DirecDoor Installation Guide Wiring to Wiegand Readers Door Contacts and Exit Request Note The DDSDC only supports one door strike DO relay one alarm DI and one exit DI on Connector...

Страница 43: ...ital Inputs DIs Note The DDSDC only supports one alarm DI and one exit DI on Connector J2 Each reader DI port J2 J4 has two digital inputs which are used for door status devices door contacts and exit...

Страница 44: ...ation of the resistors Refer to table Supervised DI REX on page 38 for the appropriate switch settings 6 Wire the supervised door DI between pin 1 Door DI and pin 2 Door DI Return 7 Wire the supervise...

Страница 45: ...recDoor Installation Guide 45 Wiring the Door Strikes Note Protection diode or MOV required at all electronic door locks Wiring Door Strikes Internal Relay Power Wiring Door Strikes External Relay Pow...

Страница 46: ...llation Guide Wiring the Fire Alarm Control Panel If a Fire Alarm Control Panel FACP is not used the jumper on J6 FACP Input must remain in place for correct operation J6 FACP Input Normally Closed Pi...

Страница 47: ...C each Wiring cable size 22 AWG 0 33 mm2 Use 22 AWG shielded cable Recommended Alpha Xtra Guard1 foil shield cable non plenum rated and Belden series security and alarm cable commercial applications s...

Страница 48: ...I O Expansion Board the DirecDoor RS485 communications must be enabled and the DIP switches set as described in the tables below Note The bus address is always 4 DDIO RS485 SW2 DIP Switch Settings Mod...

Страница 49: ...OFF OFF RS485 2 wire N A N A ON ON DDIO Input Termination Resistors and Supervised Configuration SW5 DIP Switch Settings Mode SW 5 1 SW 5 2 SW 5 3 SW 5 4 0 5K alarm 1K safe 2K alarm OFF OFF OFF ON 1K...

Страница 50: ...nting the DDIO Board in the DirecDoor Enclosure on page 51 2 Mount the DirecDoor I O Expansion Board to the DirecDoor enclosure using fasteners as shown in Figure Mounting the DDIO Board in the DirecD...

Страница 51: ...or controller 1 Install the four standoffs into the back of the DirecDoor I O Expansion Board s shown in Figure Mounting the DDIO Board in the DirecDoor Enclosure on page 51 2 Mount the DirecDoor I O...

Страница 52: ...ing To wire power and RS485 communication to the DirecDoor I O Expansion Board refer to Figure Power and RS485 Wiring on page 52 Power and RS485 Wiring Input and Output Device Wiring For input device...

Страница 53: ...ance values The purpose of this feature is to provide an additional level of flexibility to the end user and depart from the conventional 1k 1k termination The tables in this section illustrate the ex...

Страница 54: ...stor and X is left unchanged Circuit 2 Resistor Table 2 Note The resistance values used to build the tables above do not account for the additional resistance of the cable connected to the DDIO board...

Страница 55: ...hin the Normal low range represent an Alarm Restored event An Alarm Active condition is reported when the input resistance falls in the Normal high range Notice that both the Alarm Restored and Alarm...

Страница 56: ...DDIO Interface 56 DirecDoor Installation Guide Resistances Detected by PXNplus...

Страница 57: ...shielded stranded wire is recommended for the DO interface Wiring Digital Outputs DOs Digital DOs are obtained by using unassigned reader outputs When used as DOs these outputs require pull up resisto...

Страница 58: ...DO Interface 58 DirecDoor Installation Guide Wiring Output Device to DO Interface...

Страница 59: ...of OnGuard that are licensed for ACU feature support The DirecDoor controllers must have a compatible firmware version R020 or later The DirecDoor CPU uses a Type 3 SIMM flashed with R020 or later fi...

Страница 60: ...cDoor Dual NIC DirecDoor Dual NIC Primary and Secondary Network Cable Connections Configuration To configure the DirecDoor Dual NIC using the ICT refer to Controller Parameters Menu Secondary Network...

Страница 61: ...ge should be 24 VDC nominal d Use a voltmeter to measure the input voltage across J8 at pin 1 and pin 2 Verify proper polarity and voltage Pin 1 Power pin 2 or pin 4 Ground Reverse the wiring if neces...

Страница 62: ...DirecDoor Installation Guide Result A measurement of 100 ohms indicates a short circuit Correct this condition before powering up 4 Reconnect all disconnected plugs DirecDoor powers up and begins its...

Страница 63: ...tion reports Software and Hardware Requirements A supported Internet browser Refer to the OnGuard Release Notes for supported browsers and versions One of the following setups Cat 5 cable with network...

Страница 64: ...he computer you are using to access the Integrated Configuration Tool If yes disable the firewall in order to use the Integrated Configuration Tool Is your network using a proxy If yes disable the pro...

Страница 65: ...r You will need to reset your computer back to these numbers once the controller configuration is complete 6 Enter the IP address 192 168 6 5 or a similar valid IP address 192 168 6 x where x is any n...

Страница 66: ...before switching to another form This action saves your latest changes to a temporary file After completing all the forms click Reset Controller for the changes to take effect Changes will be saved to...

Страница 67: ...orts which are provided for checking and monitoring the controller These reports are used by technical support staff to troubleshoot controller issues Information Form Selection Items 1 Click the Cont...

Страница 68: ...dware related information such as boot and board version FPGA version SIMM type available hardware devices physical memory size SDRAM BRAM FLASH and FLASH memory type OS Info Displays information rela...

Страница 69: ...menu and select the Primary Network form 2 Make sure the Enable IPV4 check box is selected 3 In the Controller Information section set the controller IP addressing Static or dynamic DHCP Refer to the...

Страница 70: ...in the MAC address field Note Give the MAC address to your Network Administrator so that it can be added to the DNS database 3 Click Save 4 If this completes your controller configuration click Reset...

Страница 71: ...set the static IP address or select DHCP refer to the instructions for the Controller Parameters Menu Primary Network Form on page 68 5 Click Save 6 If this completes your controller configuration cli...

Страница 72: ...ontroller Parameters menu select Other Parameters 3 Check the Disable Integrated Configuration Tool box and click OK 4 To permanently disable the ICT click Save The ICT web page closes and the ICT is...

Страница 73: ...roller in the hardware view and select Download Firmware Alarm Monitoring System Status Window 3 When the following message appears click Yes to confirm the download Firmware Download Confirmation 4 W...

Страница 74: ...lect the following information Configuring the Host Application Configuring the DirecDoor Controller in the Host Application Set up this controller as you would any other NGP controller by using the N...

Страница 75: ...NIC in the Host Application 1 In the OnGuard System Administration application Access Panels folder use the NGP CASI Form to configure your controller 2 On the Primary Connection tab select LAN enter...

Страница 76: ...Controller Firmware Tools 76 DirecDoor Installation Guide...

Страница 77: ...nected to the DirecDoor must be shielded with shield terminated as shown in figure Typical Installation Using Shielded Cable Drain Wire on page 78 Use 8 32 SEMS screws provided The DirecDoor enclosure...

Страница 78: ...Regulatory Information 78 DirecDoor Installation Guide Typical Installation Using Shielded Cable Drain Wire Installing Ferrite...

Страница 79: ...DirecDoor Installation Guide 79 CE Regulatory Notice CE Regulatory Notice...

Страница 80: ...be protected with a Secondary Protector for Communication Circuits Listed under UL 497A The monitoring equipment must be installed in a temperature controlled environment with 24 hours of standby pow...

Страница 81: ...tional Electrical Code The DirecDoor must be used with listed card readers The exit request input circuit and initiating device must be contained within the secured area The exit device circuit must b...

Страница 82: ...ustrial supervision A clearly marked redundant system with the same configuration as the primary machine should be available as a backup In order for this product to be UL compliant the firmware level...

Страница 83: ...on page 26 If the LED is not on do the following 1 Use a voltmeter to check the power supply output It should read 24 VDC nominal If there is no output make sure the power supply is not on a switched...

Страница 84: ...but the door strike does not operate Resolution 1 Check the wiring from the door strike to the reader interface In the chapter of the appropriate reader interface refer to the section that covers wir...

Страница 85: ...nect Resolution 1 Verify your network settings host IP address OnGuard systems controller IP address and controller address OnGuard systems network mask gateway IP DHCP 2 Check the connectivity using...

Страница 86: ...on procedures Refer to Electrostatic Discharge ESD Precaution on page 16 2 Locate the clips on the right and left sides of the UCSIMMPlus board Press both clips out 3 Pull out the UCSIMMPlus board 4 T...

Страница 87: ...iew 47 resistance combinations 53 specifications 47 wiring input device 52 output device 52 power 52 RS485 52 DDSDC hardware limitations 9 21 24 27 28 29 30 31 33 37 40 42 43 44 47 59 61 66 70 80 Devi...

Страница 88: ...Parameters form 71 P Parameters form 66 Power input port 23 Power LED 23 Power over Ethernet 24 Power problems 83 Power requirements 20 Primary Network form 68 R Radio interference 16 Reader interfac...

Страница 89: ...DirecDoor Installation Guide 89 Index...

Страница 90: ...UTC Fire Security Americas Corporation Inc 1212 Pittsford Victor Road Pittsford New York 14534 USA Tel 866 788 5095 Fax 585 248 9185 www lenel com docfeedback lenel com...