Rectifying faults
132
14.2
A - Warning/fault/note
These differ depending on the device version.
Code Group
Description
Possible cause
Corrective measure
A01 Warning
Different indication of the length
section width relative to the
working width
Incorrect entry
Correct entry
A02 Fault
Deviation between the target
value and actual value applica-
tion quantity l/ha with closing
rotary control valve
Rotary
control
valve
does not move
Speed too low
Control valve visual inspec-
tion
Increase
speed
Observe
control
thresholds
A03 Fault
Both sensors of the pendulum
lock are switched
Fault in the cable
Fault in the sensor
Wrong
circuit
dis-
tance of the sensors
Cabling visual inspection
Sensors visual inspection
Check sensor circuit distance
A04
Informa-
tion
Maximum filling quantity reached
Overfilling
Incorrect
entry
for electric filling level
display, possible in-
correct sensor value
Correct entry
A05
Informa-
tion
Minimum filling quantity reached
Remaining
quantity
reached
Incorrect
entry
for electric filling level
display, possible in-
correct sensor value
Top
up
Correct
entry
Check
sensor
A06
Informa-
tion
Maximum spraying pressure set
reached
Incorrect
entry
Possible
erroneous
sensor
Fault during spraying
Correct
entry
Reduce spraying pressure
A07
Informa-
tion
Minimum spraying pressure set
reached
Incorrect
entry
Possible
erroneous
sensor
Fault during spraying
Correct
entry
Increase sprayer pressure
A08 Fault
Deviation between the target
value and actual value applica-
tion quantity l/ha with opening
rotary control valve
Rotary
control
valve
does not move
Speed too high
Control valve visual inspec-
tion
Reduce
speed
Observe
control
thresholds
A09 Fault
Pressure sensor signal errone-
ous
Fault in the cable
Fault in the sensor
Check
cabling
Check
sensor
A10 Fault
Filling level sensor signal erro-
neous
Fault in the cable
Fault in the sensor
Check
cabling
Check
sensor
Содержание Ecospray
Страница 2: ......
Страница 141: ...List of keywords 139 LIST OF KEYWORDS DISPOSAL 138 Operating voltage 15 SYMBOLS 10...