Commissioning
20
8 COMMISSIONING
8.1
Calibration 100 m
After connecting the terminal, a calibration over 100 m must be carried out.
The 100 m calibration must be carried out
on the spray surface intended, inasmuch possible,
with active four-wheel drive [if available]
- Press the key to switch on the terminal.
- Press the key to enter the setting menu.
- Press the key to enter the calibration menu.
The Calibration menu now appears.
- Press the key to enter the 100 m calibration menu.
The current pulse number now appears.
- Press the key to enter the start display for the 100 m calibration.
The Start display 100 m calibration menu now appears.
- Press the key to enter the 100 m calibration.
The Display 100 m calibration menu now appears.
- Drive a distance of 100 m.
After 100 m:
- Press the key to stop the 100 m calibration.
- Press the key to confirm the 100 m calibration.