Rectifying faults
133
14.3
B - Line breaks
These differ depending on the device version.
Code
Output
Description
Possible cause
Corrective measure
B01
SA1
Y2 boom 4 left
Cable connection defi-
cient
Visual
inspection
Replace cable, whe-
re necessary
B02
SA2
Y4 valve boom 3 left
Cable connection defi-
cient
Visual
inspection
Replace cable, whe-
re necessary
B03
SA3
Y6 valve boom 2 left
Cable connection defi-
cient
Visual
inspection
Replace cable, whe-
re necessary
B04
SA4
Y8 valve boom 1 left
Cable connection defi-
cient
Visual
inspection
Replace cable, whe-
re necessary
B05
SA5
Y10 valve boom 1 right
Cable connection defi-
cient
Visual
inspection
Replace cable, whe-
re necessary
B06
SA6
Y12 valve boom 2 right
Cable connection defi-
cient
Visual
inspection
Replace cable, whe-
re necessary
B07
PA1
Y14 valve boom 3 right
Cable connection defi-
cient
Visual
inspection
Replace cable, whe-
re necessary
B08
PA2
Y16 valve boom 4 right
Cable connection defi-
cient
Visual
inspection
Replace cable, whe-
re necessary
B09
PA3
Y18/Y19 valve pendulum lock
Cable connection defi-
cient
Visual
inspection
Replace cable, whe-
re necessary
B10 PA4
Y20/21 valve slope compensa-
tion
Cable connection defi-
cient
Visual
inspection
Replace cable, whe-
re necessary
B11
PB1
Y22 oil flow 4/3 lines
Cable connection defi-
cient
Visual
inspection
Replace cable, whe-
re necessary
B12
PB2
Y23 oil flow 3/3 lines
Cable connection defi-
cient
Visual
inspection
Replace cable, whe-
re necessary
B13
PB3
Y24 oil flow valve lifting mast
Cable connection defi-
cient
Visual
inspection
Replace cable, whe-
re necessary
B14 PB4
free
Cable connection defi-
cient
Visual
inspection
Replace cable, whe-
re necessary