3
– ELECTRICAL INSTALLATION RULES
Prior to installation, make sure there is a circuit breaker installed with a distance between the contacts that allows
for complete disconnection when there is a category III overload and that provides protection against current
leakage equal to 30 mA. The circuit breaker must be installed on the power supply in compliance with installation
rules. If the power supply is not working properly, the machine can cause transitory voltage drops
.
The electrical safety of this machine is only ensured when it is correctly connected to an efficient earthing system
in compliance with the electrical safety laws in force. This fundamental safety requirement must be verified. If in
doubt, request that a qualified electrician inspect the system. The manufacturer cannot be held responsible for
any damage caused by the lack of an earthing system on the electrical supply.
It is unadvisable to use adaptors, multiple plugs, and/or extension cords. If their use is indispensable, only use
simple or multiple adaptor plugs and extension cords that are in compliance with safety laws. Make sure that
these devices do not exceed the voltage capacity marked on the simple adaptor and on extension cords, and the
maximum voltage marked on the multiple adaptor.
Check that the type of connection and voltage correspond with the information on the technical nameplate.
4
– EQUIPOTENTIAL CONNECTION
This type of connection, required by some laws, prevents
differences in the electric potential level between the earthing
connections of equipment installed in the same room. This
machine is provided with a clamp (
1
)
UNDERNEATH THE
BASE
for connection to an external equipotential cable. After
installation, this type of connection
MUST
be made:
use a cable with a nominal section in compliance with the laws
in force;
Connect one end of the cable to the terminal and the other end
to the earthing of adjacent equipment;
Failure to follow this safety norm releases the manufacturer
from any responsibility for machine breakdowns or damage to
people or property
.
N.B.: DO NOT CONNECT TO THE POWER SUPPLY EARTHING BECAUSE IT IS NOT CONSIDERED AN
EQUIPOTENTIAL CABLE CONNECTION
.
Bear in mind that
GEMME ITALIAN PRODUCERS srl
is not responsible for damage caused by improper electrical
connections, and that the installer is responsible for any damage.
Содержание eliulietta PL1S
Страница 46: ...Pag 46 1 70 2 2 1 20 10 32 C 50 F 90 F...
Страница 47: ...Pag 47 3 3 30 4 1 N B GEMME ITALIAN PRODUCERS srl...
Страница 48: ...Pag 48 5 100 8 F 4 5 D 6 2 3 6 I O I 1 1 2 7 1 4 1...
Страница 49: ...Pag 49 8 8 1 4 1 2 1 100 1 200...
Страница 50: ...Pag 50 9 CAUTION HOT O 10 1 3 N 7...
Страница 51: ...Pag 51 11 12 13 4 I 4 0 9 6 1 9 2 3 4 9 5 6 5 5 7...
Страница 52: ...Pag 52 14 10 12 10 12 11 13 10 12 10 12 12 10...
Страница 53: ...Pag 53 15 HACCP 3 5 10 5 10 30 1 10 20 1...
Страница 54: ...Pag 54 16 16 100 8 10 9 By pass 9...
Страница 55: ...Pag 55 13 9 p 8 9 By pass...
Страница 56: ...Pag 56 17 8 F 1 N B 0 5 5 2 3 3...
Страница 57: ...Pag 57 4 5 5 6 2 7 4 8 9 10...
Страница 73: ...McGrp Ru McGrp Ru...