CAUTION
Overtightening the screws may cause the plastic
enclosure of the charger to break.
10. Install the cable gland in the bottom left cut-out area created at step 7. Fix
the cable gland into position by tightening the lock nut.
11. Strip the main insulation of the power supply cable in such a way that 2
cm of insulation will be left inside the plastic enclosure of the charger.
12. Measure and cut the 3-wires of the power supply cable, in such a way
that they can be easily and fully inserted into the cable connectors
mounted on PCB.
13. Strip 12mm of insulation for each of the 3-wires of the power supply
cable. (Fig. 7)
14. Insert the power supply cable through the bottom cable gland. To
maintain the protection class (IP54) of the charger, the supplied cable
gland must be used.
15. Open the levers of the WAGO™ connectors that are mounted on the left
side of the PCB.
Fig. 6 Mounting points of the 1P7K
Charger
Sealing