Chapter 7: DEC-6804 Decoder and DES-6804 Decoder with Frame Synchronizer
Parameter Groups
94
6800/7000 Series - Audio and Video Multi/Demultiplexing Products Installation and Operation Manual
Common Parameter Group B
SW1
Position
Function
SW3 Down
SW3 Up
Default Value
0
Group Select
Group Decrease
Group Increase
Group A
1
Freeze (DES-6804 only)
Off
On
Off
2
Freeze mode
(DES-6804 only)
Field
Frame
Field
3
Field Freeze mode
(DES-6804 only)
Field 1
Field 2
Field 1
4
H Phase
(DES-6804 only; this
function is available in both
Delay
mode and
Synchronizing
mode)
[wraps]
Decrease
Increase
Factory Settings
5
V Phase
(DES-6804 only; this
function is available in both
Delay
mode and
Synchronizing
mode)
[wraps]
Decrease
Increase
6
Input Video Active Lines
With/Without Setup
(Disabled in PAL-B)
With
Without
With
7
Black Clip
Disable
Enable
Disable
8
Hot Switch
(DES-6804 only; Group A
Genlock
parameter must be
set to
Free-Run,
or
Sync
mode
parameter
must be
set to
Synchronizing
mode)
Three options are available in a clipped
list:
Disable
,
Enable
, and
Auto
•
Disable
: Passes video including any
input disturbances
•
Enable
: Freezes or selects test signal
•
Auto
: TBC activation will disable
the hot switch
Auto
Содержание 6800/7000 Series