TS12P, Technical Data
60
7.4
Distance Measurement - Long Range (LO mode)
Range
The range of the long range measurements is the same for R400 and R1000.
Atmospheric
conditions
Accuracy
*1 does not include radio transfer time to the CS.
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy. The display resolution is 0.1 mm.
Characteristics
Reflector
Range A
Range B
Range C
[m]
[ft]
[m]
[ft]
[m]
[ft]
Standard prism (GPR1)
2200
7300
7500
24600
>10000 >32800
Range of measurement:
1000 m to 12000 m
Display unambiguous:
up to 12000 m
Range A:
Strong haze, visibility 5 km; or strong sunlight, severe heat shimmer
Range B:
Light haze, visibility about 20 km; or moderate sunlight, slight heat
shimmer
Range C:
Overcast, no haze, visibility about 40 km; no heat shimmer
Standard measuring
std. dev.
ISO 17123-4
Measure time,
typical [s]*
1
Measure time,
maximum [s]
Long Range
5 mm + 2 ppm
2.5
12
Principle:
Phase measurement
Type:
Coaxial, visible red laser
Carrier wave:
658 nm
Measuring system:
System analyser basis 100 MHz - 150 MHz