TS12P, Technical Data
65
7.8
General Technical Data of the Instrument
Telescope
Compensator
Level
Control unit
Instrument Ports
Magnification:
30 x
Clear objective diameter:
40 mm
Focusing:
1.7 m/5.6 ft to infinity
Field of view:
1°30’/1.66 gon.
2.7 m at 100 m
Angular accuracy
TS12P ["]
Setting accuracy
Setting range
["]
[mgon]
[’]
[gon]
2
0.5
0.2
4
0.07
3
1.0
0.3
4
0.07
5
1.5
0.5
4
0.07
7
1.5
0.5
4
0.07
Circular level sensitivity:
6’/2 mm
Electronic level resolution:
2"
Display:
1/4 VGA (320 x 240 pixels), colour, graphics
capable LCD, illumination, touch screen
Keyboard:
28 keys
including 6 function keys and 12 alphanumeric
keys, illumination
Angle Display:
360°’", 360° decimal, 400 gon, 6400 mil, V %
Distance Display:
m, ft int, ft us, ft int inch, ft us inch
Touch screen if fitted:
Toughened film on glass
Port
Name
Description
Port 1
Port 1
• 5 pin LEMO-0 for power, communication, data transfer.
• This port is located at the base of the instrument.
Port 2
Handle
• Hotshoe connection for RadioHandle with RCS.
• This port is located on top of Communication side cover.
Port 3
BT
• Bluetooth module for communication.
• This port is housed within Communication side cover.