TS12P, Technical Data
58
7.2
Distance Measurement with Reflectors
Range
Atmospheric
conditions
Measurements can be made to reflector tapes over the entire range without external
ancillary optics.
Accuracy
Accuracy refers to measurements to standard prisms.
*1 does not include radio transfer time to the CS.
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy.
The display resolution is 0.1 mm.
Characteristics
Reflector
Range A
Range B
Range C
[m]
[ft]
[m]
[ft]
[m]
[ft]
Standard prism (GPR1)
1800
6000
3000
10000
3500
12000
Three standard prisms (GPR1) 2300
7500
4500
14700
5400
17700
360° prism (GRZ4, GRZ122)
800
2600
1500
5000
2000
7000
360° Mini prism (GRZ101)
450
1500
800
2600
1000
3300
Mini prism (GMP101)
800
2600
1200
4000
2000
7000
Reflector tape (GZM31)
60 mm x 60 mm
150
500
250
800
250
800
Machine Automation power
prism (MPR122)
For Machine Control
purposes only!
800
2600
1500
5000
2000
7000
Shortest measuring distance: 1.5 m
Range A:
Strong haze, visibility 5 km; or strong sunlight, severe heat shimmer
Range B:
Light haze, visibility about 20 km; or moderate sunlight, slight heat
shimmer
Range C:
Overcast, no haze, visibility about 40 km; no heat shimmer
EDM
measuring mode
std. dev.
ISO 17123-4,
standard prism
std. dev.
ISO 17123-4,
tape
Measurement
time, typical [s]*
1
Standard
1 mm + 1.5 ppm
5 mm + 2 ppm
2.4
Fast
3 mm + 1.5 ppm
5 mm + 2 ppm
0.8
Tracking
3 mm + 1.5 ppm
5 mm + 2 ppm
< 0.15
Principle:
Phase measurement
Type:
Coaxial, visible red laser
Carrier wave:
658 nm
Measuring system:
System analyser basis 100 MHz - 150 MHz