GeoCOM Reference Manual
Theodolite Measurement and Calculation – TMC
Leica TPS1200 – Version 1.50
178
17.7.2
TMC_GetSignal - getting information about the EDM signal intensity
TMC_GetSignal..............................................................................................................................................................................................................................................................................
.................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... 2022
2022 ................................................................................................................................................................................................................................................................TMC_GetSignal
C-Declaration
TMC_GetSignal(TMC_EDM_SIGNAL &Signal)
VB-Declaration
VB_TMC_GetSignal(Signal As TMC_EDM_SIGNAL)
ASCII-Request
%R1Q,2022:
ASCII-Response
%R1P,0,0:
RC,SignalIntensity[double],Time[long]
Remarks
This function returns information about the intensity of the EDM signal. The function can only perform a
measurement if
the signal measurement program is activated. Start the signal measurement program
with
TMC_DoMeasure
where
Command = TMC_SIGNAL
. After the measurement the EDM must be switched off
(use
TMC_DoMeasure
where
Command = TMC_CLEAR
). While measuring there is no angle measurement data
available.
Parameters
Signal Out
Signal intensity information.
Return-Code Names and Return-Code Values
GRC_OK
0 Execution
successful.
GRC_TMC_SIGNAL_ERROR
1294 Error
within
signal measurement.
At repeated occur call service.
GRC_ABORT
8
Measurement through customer aborted.
GRC_SHUT_DOWN
12
System power off through customer.
See Also
TMC_DoMeasure
Example
GRC_TYPE Result;
TMC_SIGNAL Signal;
TMC_DoMeasure(TMC_SIGNAL);
do
{
Result=TMC_GetSignal(Signal);
if(Result==GRC_OK)
{
.
.
.
}
}while(Result==GRC_OK);