Return-Code names and return-code values
Leica TPS1200 – Version 1.50
197
GRC_ATA_HZ_STRANGE_L
529
0x211
Strange light in Hz-direction.
GRC_ATA_V_STRANGE_L 530
0x212
Strange light in V-direction.
GRC_ATA_SLDR_TRANSFER_PENDING 531
0x213 On multiple ATA_SLDR_OpenTransfer.
GRC_ATA_SLDR_TRANSFER_ILLEGAL 532 0x214
No ATA_SLDR_OpenTransfer happened.
GRC_ATA_SLDR_DATA_ERROR
533
0x215
Unexpected data format received.
GRC_ATA_SLDR_CHK_SUM_ERROR
534
0x216
Checksum error in transmitted data.
GRC_ATA_SLDR_ADDRESS_ERROR
535
0x217
Address out of valid range.
GRC_ATA_SLDR_INV_LOADFILE
536
0x218
Firmware file has invalid format.
GRC_ATA_SLDR_UNSUPPORTED
537
0x219
Current (loaded) firmware doesn't support
upload.
GRC_ATA_PS_NOT_READY 538
0x21A
PS-System is not ready.
GRC_ATA_ATR_SYSTEM_ERR
539
0x21B
ATR system error
EDM
768 0x300
RetCodeName Value
HexVal
Description
GRC_EDM_SYSTEM_ERR
769
0x301
Fatal EDM sensor error. See for the exact
reason the original EDM sensor error number.
In the most cases a service problem.
GRC_EDM_INVALID_COMMAND
770
0x302
Invalid command or unknown command, see
command syntax.
GRC_EDM_BOOM_ERR 771
0x303
Boomerang
error.
GRC_EDM_SIGN_LOW_ERR
772
0x304
Received signal to low, prism to far away, or
natural barrier, bad environment, etc.
GRC_EDM_DIL_ERR 773
0x305
obsolete
GRC_EDM_SIGN_HIGH_ERR
774
0x306
Received signal to strong, prism to near,
stranger light effect.
GRC_EDM_TIMEOUT
775
0x307
Timeout, measuring time exceeded (signal too
weak, beam interrupted,..)
GRC_EDM_FLUKT_ERR
776
0x308
to much turbulences or distractions
GRC_EDM_FMOT_ERR
777
0x309
filter motor defective
GRC_EDM_DEV_NOT_INSTALLED 778
0x30A
Device like EGL, DL is not installed.
GRC_EDM_NOT_FOUND 779
0x30B
Search
result
invalid. For the exact explanation,
see in the description of the called function.
GRC_EDM_ERROR_RECEIVED 780
0x30C
Communication ok, but an error reported from
the EDM sensor.
GRC_EDM_MISSING_SRVPWD
781
0x30D
No service password is set.
GRC_EDM_INVALID_ANSWER
782
0x30E
Communication ok, but an unexpected answer
received.
GRC_EDM_SEND_ERR
783
0x30F
Data send error, sending buffer is full.
GRC_EDM_RECEIVE_ERR
784
0x310
Data receive error, like parity buffer overflow.
GRC_EDM_INTERNAL_ERR
785
0x311
Internal EDM subsystem error.
GRC_EDM_BUSY 786
0x312
Sensor
is
working already, abort current
measuring first.
GRC_EDM_NO_MEASACTIVITY 787
0x313
No
measurement activity started.
GRC_EDM_CHKSUM_ERR
788
0x314
Calculated checksum, resp. received data
wrong (only in binary communication mode
possible).
GRC_EDM_INIT_OR_STOP_ERR 789
0x315
During
start up or shut down phase an error
occured. It is saved in the DEL buffer.
GRC_EDM_SRL_NOT_AVAILABLE
790
0x316
Red laser not available on this sensor HW.
GRC_EDM_MEAS_ABORTED 791
0x317
Measurement will be aborted (will be used for
the laser security)
GRC_EDM_SLDR_TRANSFER_PENDING 798
0x31E
Multiple OpenTransfer calls.
GRC_EDM_SLDR_TRANSFER_ILLEGAL
799
0x31F
No open transfer happened.
GRC_EDM_SLDR_DATA_ERROR
800
0x320
Unexpected data format received.
GRC_EDM_SLDR_CHK_SUM_ERROR
801
0x321
Checksum error in transmitted data.
GRC_EDM_SLDR_ADDR_ERROR
802
0x322
Address out of valid range.
GRC_EDM_SLDR_INV_LOADFILE
803
0x323
Firmware file has invalid format.
Содержание TM30 Series
Страница 1: ...Leica TPS1200 Leica TS30 TM30 GeoCOM Reference Manual Version 1 50 English...
Страница 120: ...GeoCOM Reference Manual File Transfer FTR Leica TPS1200 Version 1 50 120 while bLast TRUE FTR_AbortList...
Страница 136: ...GeoCOM Reference Manual Motorisation MOT Leica TPS1200 Version 1 50 136 handle error...