56
SPRINTER 100/100M/200/200M
Messages
E114
Invalid Measurement !
Make another measurement. If further meas-
urement proved to be futile, check staff position
and Inverse Staff setting, check the lighting
condition at the staff and stray light, check
focusing and targeting, check if sufficient length
of barcode in the field of view.
E115
Temperature Sensor Error !
Cover the objective telescope with a hand and
switch ON the instrument. Hardware communi-
cation failed.
E116
Adjustment Error !
Carry out the adjustment with guided steps,
make sure instrument is level and staff is truly
vertical in normal position. Collimation is out of
correction range.
E117
RL Change Not Allowed !
Exit to default measurement mode by pressing
HEIGHT/DISTANCE key, and change the
Reference reduced level in the INPUT RL menu
mode.
E119
Staff Blocked
Not enough barcode length for measurement.
E120
Image sensor Error!
Contact services.
E121
Adjustment Inverse Staff Not
Allowed!
Check the staff orientation.
No.
Error message
Counter measure / causes