background image

PLEASE RET

AIN 

THIS INSTR

UCTION MANUAL!

2500E P

rofessional Electr

onic Level

Chalumeau Oxycoupeur/

Soudeur/de Br

asage Spécialisé

Nivel electr

ónico pr

ofesional I

RW

IN

®

 2500E 

FEA

TU

RE

S:

 

-  Wide screen easy-to-read L

CD with bac

klight

-  Display automatically inver

ts when the level is upside down 

-  Audible beep is made at 0° and 90°  -  U

NIT button show

s degrees, slope percent

age, and pitc

   

in I

N/

FT and mm/m

-  Automatic shut-off after 3 minutes of inactivit

y

-  R

EF 

(Reference/F

alse Zero)

 button easily calibrates measurements

-  P

ush-button memor

y to hold measured angle

-  Horizont

al and ver

tical vials for bac

k-up and calibration

-  Plumb-site

® 

for more accurate plumb readings

-  Over-molded, removable end-caps for protection and accuracy

CA

RA

CTÉ

RI

STI

QU

ES: 

 

-  Grand écran A

CL facile à lire avec rétroéclairage

-  L'affic

hage s'inverse automatiquement lorsque le niveau est à l'envers 

-  Un signal sonore se fait entendre à 0° et à 90°  -  La touc

he « U

NIT » 

(UNI

TÉ)

 affic

he les degrés, le pourcent

age de pente et 

    l'inclinaison en P

O/

PI (I

N/

FT) et en mm/m

-  Arrêt automatique après 3 minutes d'inactivité -  T

ouc

he « R

EF » 

(référence/faux zéro)

 ét

alonne facilement les mesures

-  Le bouton-poussoir de mémoire permet de figer l'angle mesuré -  Fioles horizont

ales et ver

ticales pour corroborer les mesures et pour l'ét

alonnage

-  T

ec

hnologie Plumb Site® pour une lecture précise de l'aplomb

-  Embouts amovibles surmoulés pour la protection et la précision

CAR

AC

TE

ST

ICAS

-  P

ant

alla amplia iluminada y V

CL fácil de leer

-  La imagen se invier

te automáticamente con el nivel

-  P

roduce tono audible a 0° y 90°

-  El control de U

NI

DA

D exhibe grados, porcent

aje de inclinación y declive 

   en P

UL

G/

PI

ES y en mm/m

-  Apagado automático después de 3 minutos de inactividad -  El botón R

EF 

(referencia/ cero falso)

 calibra fácilmente las medidas

-  Memoria de botón de cont

acto para retener ángulos medidos

-  Ampollet

as horizont

al y ver

tical para reser

va y calibrado

-  Plumb-site

®

 para lecturas de plomada más exact

as

-  T

apas extremas sobre moldeadas removibles ofrecen protección y exactitud

OVE

RVI

EW

:

1.

  

IR

W

IN 2500E P

rofessional Electronic Level

2

.

 

Plumb-site dual-sided viewing 

HO

W TO U

SE:

-  Be sure to read all instructions before using your I

RW

IN Electronic Level.

-  T

his leve

l can be used both indoors and outdoors for horizont

al, ver

tical, and angled  

   alignments.

-  T

wo (2) “A

AA

” alkaline batteries 

(included)

 are needed for operation

.

BUT

TO

N F

UN

CTI

ON

S:

Power Button 

Press the power button to turn on display and bac

klight. Light will automatically turn off after 

20 seconds. P

ush again to turn bac

klight on as needed. P

ress and hold the button to turn 

display off. T

he display will automatically turn off after 3 minutes of inactivit

y to save 

batter

y life.

Audio Button

Push audio button to hear beep when level or plumb. T

he speaker icon will show in display if 

audio is turned on.

RE

Second Reference/

False Zero: T

o set a second reference angle or false zero, press the R

EF 

button. T

he display will c

hange to “0.0” and the “S” (for second reference) will show in display. 

To reset, press the R

EF button again.

  

 

LI

M

ITE

D WA

RR

ANT

Y

IR

W

IN Industrial T

ool Company 

(“Seller”)

 warrants that the P

roduct shall be free of 

defects in materials and workmanship under normal use for a period of t

wo (2) years 

from the date of purc

hase of the P

roduct by the end user 

(“Buyer”)

. T

he vials are 

warranted against fogging, leakage and breakage for the lifetime of that par

t. T

his 

warrant

y does not cover alteration, modification, damage in transit, negligence, abuse, 

misuse, accidents, normal wear and tear, exposure to moisture, or damage due to 

environment

al or natural elements. 

Seller’

s sole and exclusive obligation under this warrant

y shall be, at Seller’

s option, to 

repair or replace the P

roduct without c

harge. T

o receive repair or replacement, either 

return the defective P

roduct to the outlet where purc

hased or call Customer Ser

vice at 

1-800-G

O-I

RW

IN to arrange for the product return to us. Seller reser

ves the right to 

request proof of purc

hase in conjunction with any suc

h return. No warrant

y of 

merc

hant

abilit

y or fitness for par

ticular purpose is made or to be implied. In no event shall 

Seller be liable for any other costs, or damages, including lost profits, incident

al, special or 

consequential damages.

2

5

8

3

4

6

7

 Calibr

ation: 

 

     Follow these steps to recalibrate the level:

 

(1) P

ress and hold the R

EF button before turning the unit O

N. 

 

(2) T

urn the unit on and the word “C

AL

” will appear in the display. 

 

(3) Release the R

EF button and place the level on a known level sur

face. 

 

(4) P

ress the R

EF button again and “C

AL1” will show on the display. 

 

(5) Once the measurement displays, rot

ate the level 180° end-to-end.  

 

(6) P

ress the R

EF button again and “C

AL2” will briefly show on the display.

 

 

The level is now calibrated and ready for use. If the display reads “Err” after this  

 

procedure, the reference sur

face used was not level and the procedure should be  

 

repeated from the beginning using a different reference sur

face.

 Note: 

 

W

e recommend c

hec

king calibration after a fall or any significant temperature  

 

 

change (+/- 20°F) since the previous calibration.

Press the H

OL

D button to hold or release the current display. “H” will show in display if 

display is on hold to temporarily record measured angle.  P

ress the H

OL

D button again to 

return to normal operation.

Press the U

NIT button to switc

h bet

ween the available display units: degrees (°), slope (%), 

pitc

h (I

N/

FT), pitc

h (mm/m). F

or the I

N/

FT unit setting, the “+” or “-” indicators provide 

additional accuracy to the display reading, whic

h is in 1/8

th

 increments. T

he “+” indicates to 

add 1/24

th

 to the display reading and the “-” indicates to subtract 1/24

th

 from  the display 

reading. F

or example, if the reading is “5/8+ I

N/

FT”

, the actual measurement is 16/24

th

. If 

the reading is “5/8- I

N/

FT”

, the actual measurement is 14/24

th

. If the reading is “5/8 I

N/

FT”

it is exactly 5/8

th

 or 15/24

th

 

TECH

NIC

AL

 SP

ECI

FIC

AT

IONS

:

Electronic Module Accuracy:

 

        ±0.1° at 0° and 90° 

(horizontal/vertical)

 

 

 

        ±0.2° at all other positions

Vial Accuracy:

 

 

        ±0.029° or 0.5mm/m 

(normal and inverted positions)

Power Supply:

 

 

         T

wo (2) “A

AA

” alkaline batteries

Operating T

emperature Range:  

      -4°F – +122°F/-20°C – +50°C

Storage T

emperature Range:

         -22°F – +158°F/-30°C – +70°C

Splash/Dust Resistance:

 

         According to st

andard I

P54 

PROB

LE

M

 SOL

VI

NG

:

-  If display screen does not light up when level is turned o

n, be sure that bat

teries are  

   correctly inser

ted and c

hec

k batter

y c

harge, as replaceme

nt may be needed.

-  

If you experience other problems, cont

act I

RW

IN Customer Ser

vice at 1-800-G

O-I

RW

IN.

¡F

AVOR CONSERVE EST

AS INSTR

UCCIONES! 

PRIÈRE DE CONSERVER CES INSTR

UCTIONS!

APPLICATIONS:

-  Roof layout and framing

-  Drywall projects

-  Stairways, handrails, and ADA access

-  Run-off areas, pipes, and drainage slopes

-  Decking and landscaping

2500E Professional Electronic Level
Chalumeau Oxycoupeur/Soudeur/de Brasage Spécialisé
Nivel electrónico profesional IRWIN

®

 2500E 

12.

  

Angle direction indicator

13.

  

Audio indicator

14.

  

Hold indicator

 

 6.

  

Power button

 

 7.

  

Audio button

 8.

  

Reference button for false zero & calibration

15.

  

Second reference 

(false zero)

 indicator

16.

  

Batter

y power indicator

17.

  

Unit Indicators

3.

  

Over-molded removable end-caps

4.

  

Electronic module

5.

  

Display with bac

klight

 9.

  

Hold button

10.

  

Unit button c

hanges bet

ween °, %, I

N/

FT

, & mm/m

11.

  

Batter

y compar

tment 

(back of electronic module)

VU

E D'E

NS

EM

BL

E:

1.

  

Nivea

u électronique professionnel 2500E 

    de I

RW

IN

2

.

 

Visualisation à deux faces Plumb Site

12.

 

 Indicateur d'angle

13.

 

 Indicateur d'audio

14.

  

Indicateur « Hold »

 

(figer)

 

 6.

  

Touc

he d'aliment

ation

 7.

  

Touc

he d'audio

 8.

  

Touc

he « Ref » 

(référence)

 pour faux zéro 

      et l'ét

alonnage

 9.

  

Touc

he « Hold »

 

(figer)

15.

  

Indicateur de la deuxième référence 

(faux zéro)

16.

  

Indicateur de la puissance des piles

17.

  

Indicateurs d'unités

1.

2.

3.

4.

5.

3.

  

Embouts amovibles surmoulés

4.

  

Module électronique

5.

  

Écran avec rétroéclairage

10.

  

La touc

he « Unit » 

(unité)

 permet de faire défiler 

      les unités suivantes : °, %, I

N/

FT (P

O/

PI), et mm/m

11.

  

Compar

timent à piles 

     

(à l'arrière du module électronique)

APPLICATIONS:

-  La charpente de toiture et sa disposition

-  Les projets de cloisons sèches

-  Les escaliers, les mains courantes et les accès ADA (American with Disabilities Act)

-  Les zones de ruissellement, les tuyaux et les pentes de drainage

-  Les terrasses et l'aménagement paysager

12.

13.

14.

15.

16.

17.

7.

6.

11.

8.

9.

10.

1.

2.

3.

4.

5.

APLICACIONES:

- Trazado de techos y ensamblaje

- Proyectos con tabla de yeso

- Escaleras, pasamanos y accesos ADA

- Desagües, tubería, y vertientes de drenaje 

- Tableros y paisajismo

7.

6.

11.

8.

9.

10.

12.

13.

14.

15.

16.

17.

M

OD

E D'E

M

PL

OI:

-  Assurez-vous de lire toutes les instructions avant d'utiliser votre niveau 

   électronique I

RW

IN.

-  Ce niveau peut être utilisé aut

ant à l'intérieur qu'à l'extérieur pour des mises à niveau  

    

   horizont

ales, ver

ticales et inclinées.

-  Deux (2) piles alcalines « A

AA » 

(comprises)

 sont nécessaires pour faire fonctionner 

   le niveau.

FONC

TIONS

 DES

 T

OUCH

ES

:

T

ouc

he d'aliment

ation

Appuyez sur la touc

he d'aliment

ation pour allumer l'écran et le rétroéclairage. L'éclairage 

s'éteindra automatiquement après 20 secondes. Appuyez à nouveau pour allumer le rétroéclai

-

rage si nécessaire. Appuyez et maintenez la touc

he enfoncée pour éteindre l'écran. L'écran 

s'éteindra automatiquement après 3 minutes d'inactivité pour économiser la durée de vie des 

piles.

 

Touc

he d'audio

Appuyez sur la touc

he d'audio si vous désirez entendre un signal sonore lorsque l'instrument est 

à niveau ou d'aplomb. L'icône en forme de haut-parleur apparaîtra à l'écran si l'audio est activé.

   

Содержание 2500E

Страница 1: ......

Страница 2: ...s le pourcentage de pente et l inclinaison en PO PI IN FT et en mm m Arr t automatique apr s 3 minutes d inactivit Touche REF r f rence faux z ro talonne facilement les mesures Le bouton poussoir de...

Страница 3: ...Audio button 8 Reference button for false zero calibration 15 Second reference false zero indicator 16 Battery power indicator 17 Unit Indicators 3 Over molded removable end caps 4 Electronic module 5...

Страница 4: ...ly turn off after 20 seconds Push again to turn backlight on as needed Press and hold the button to turn display off The display will automatically turn off after 3 minutes of inactivity to save batte...

Страница 5: ...ace Note We recommend checking calibration after a fall or any significant temperature change 20 F since the previous calibration Press the HOLD button to hold or release the current display H will sh...

Страница 6: ...atteries Operating Temperature Range 4 F 122 F 20 C 50 C Storage Temperature Range 22 F 158 F 30 C 70 C Splash Dust Resistance According to standard IP54 PROBLEM SOLVING If display screen does not lig...

Страница 7: ...damage due to environmental or natural elements Seller s sole and exclusive obligation under this warranty shall be at Seller s option to repair or replace the Product without charge To receive repai...

Страница 8: ...rence pour faux z ro et l talonnage 9 Touche Hold figer 15 Indicateur de la deuxi me r f rence faux z ro 16 Indicateur de la puissance des piles 17 Indicateurs d unit s 1 2 3 4 5 3 Embouts amovibles...

Страница 9: ...Appuyez sur la touche d alimentation pour allumer l cran et le r tro clairage L clairage s teindra automatiquement apr s 20 secondes Appuyez nouveau pour allumer le r tro clai rage si n cessaire Appuy...

Страница 10: ...et placez le niveau sur une surface de niveau reconnue 4 Appuyez nouveau sur la touche REF et CAL1 appara tra l cran 5 Une fois que les mesures apparaissent l cran faites pivoter le niveau de 180 d un...

Страница 11: ...1 24e la lecture figurant l cran Par exemple si la lecture est de 5 8 IN FT la mesure r elle est de 16 24e Si la lecture est de 5 8 IN FT la mesure r elle est de 14 24e Si la lecture est de 5 8 IN FT...

Страница 12: ...midit ou les dommages caus s par les l ments naturels ou environnementaux La seule obligation exclusive du vendeur selon les conditions de cette garantie sera la discr tion du vendeur de r parer ou d...

Страница 13: ...ot n de referencia cero falso y calibrado 9 Bot n de retenci n de datos 15 Indicador cero falso segunda referencia 16 Indicador de potencia de las bater as 17 Indicador de unidades 3 Tapas extremas so...

Страница 14: ...para encender la pantalla y la luz posterior La luz se apaga autom ticamente despu s de 20 segundos Presione nuevamente para encender la luz posterior seg n la necesite Presione y sostenga el bot n p...

Страница 15: ...5 Una vez que aparezca la medida rote el nivel 180 de un extremo al otro 6 Presione el bot n REF nuevamente y la pantalla exhibir brevemente la abreviatura CAL2 El nivel se encuentra calibrado y listo...

Страница 16: ...s exactamente 5 8 o 15 24 ESPECIFICACIONES T CNICAS Precisi n de m dulo electr nico 0 1 a 0 y 90 horizontal vertical 0 2 en toda otra posici n Precisi n de la ampolleta 0 029 o 0 5mm m posiciones norm...

Страница 17: ...ebido al medio ambiente o elementos naturales La nica y exclusiva obligaci n del vendedor bajo esta garant a ser la de reparar o reemplazar el producto gratuitamente Para aprovechar el servicio de rep...

Страница 18: ...xecutive Dr Huntersville NC 28078 USA 1 800 GO IRWIN www irwin com Plumb site is a trademark of Kapro Industries Ltd Plumb site es una marca de f brica de Kapro Industries Ltd Plumb Site est une marqu...

Отзывы: