Operating instructions
Settings and displays
24
7-pin socket
1. Connect the connecting cable of the control panel to the 7-pin signal
plug of the tractor.
2. Set the EHR signal of the spreader depending on whether the tractor
emits the hydraulic signal when lifting or lowering.
Sensor signal
1
1
3. Secure the sensor in the joint area of the lower link.
4. Secure the magnetic encoder to the lower link.
5. Set the position of the sensor and the magnetic encoder.
Maximum distance 10 mm.
• Hydraulics lowered:
Sensor not in field of magnetic encoder.
Hydraulics at the height where the slide should close or open:
Sensor just reaches field of magnetic encoder.
• Hydraulics lifted:
Sensor must still be in field of magnetic encoder. When the
hydraulics are lifted, the sensor must not leave the field of the
magnetic encoder, as otherwise the slide will open again.
Please note that the contact surfaces
1
of the sensor are only located on the
left and right sides.