15
Risk of collision
-
Adjust the drive speed so that it is safe with regard to the ground conditions.
-
When operating the lift, take into account that visibility may be limited
-
The operator must follow all regulations concerning the use of safety equipment on the
work site
-
Make sure that there are no overhead obstacles on the work site that could prohibit
lifting of the platform, or objects that might cause a collision
-
Do not operate this access platform in the working area of another overhead lifting
device or similar equipment that is moving, unless this lifting device is secured so that
there is no risk of collision
-
Beware of crushing hazard when holding the handrail of the platform in a potential
collision situation
-
When operating the lift, beware of limited visibility and trapping hazard.
Risk of electric shock
-
This machine is not insulated from voltage or protected against contact with live parts
-
Do not touch the machine if it comes in contact with a live electric line
-
Persons on the platform or at ground level must not touch or operate the machine before
power has been cut off from the electric line
-
During welding repairs, using any part of this access platform as an earth conductor is
prohibited
-
Do not use this access platform during a thunderstorm or in high winds
-
Leave clearance for electric lines, taking into account movements of the platform,
movements of electric lines, and high winds and gusts.
The minimum safety clearances for overhead cables are shown in the following table. The
clearances for the most commonly used voltages in overhead lines are as follows:
VOLTAGE
MIN. DISTANCE
0 – 1,000 V
2 m
1 – 45 kV
3 m
110 kV
5 m
220 kV
5 m
400 kV
5 m