14
_________________________________________________________________________________________
5.5 Electrocution hazard
-
This access platform is not voltage insulated nor protected against contact with voltage
carrying parts, or when approaching them.
-
Do not touch the machine if it comes in contact with voltage carrying electric line.
-
Persons on the platform or at ground level must not touch or operate the platform before
power has been cut off from the electric line.
-
During welding repairs, it is not allowed to use any part of this access platform as earth
conductor.
-
Do not use this access platform during thunderstorm or high winds.
-
Leave clearance to electric lines, taking into account movements of platform,
movements of electric line, and high winds and gusts.
The minimum safety clearances to voltage carrying electric lines are shown in the following
table. These clearances must be respected.
VOLTAGE
MIN. DISTANCE
0
– 1000V
2 m
1- 45 kV
3 m
110 kV
5 m
220 kV
5 m
400 kV
5 m
5.6 Explosion / fire hazard
-
It is not allowed to start the motor/engine in a place where one can smell LPG, petrol,
solvent or other flammable substance.
-
Do not fill with fuel when the engine is running.
-
Charge the battery only in places with sufficient ventilation, where there is no open fire
or no works which could cause spark emissions (like welding).
5.7 Daily inspection before starting operation
- ground
- controls
- supports
- driving area
- horizontal levelling
- platform
- emergency stop button
- oil leakages
- emergency lowering
- working area
ATTENTION! If you note faults or missing equipment on this access platform, do not put it into
operation before the faults have been corrected. Never set the access platform up in a place
where the ground may be too soft. Beware of soft grounds and potholes in particular
.
Содержание 125